Well Details

Well ID: 34-005-22462
Loading map...
Country: United States
State: Ohio
County: Ashland
Municipality: Perry Township
Operator Name: DEEP RESOURCES LLC
Well Pad ID:
Farm/Lease Name: ANDERSON UNIT
License Status: Active Injection
License Date: 1984-07-31
Spud Date: 1984-07-31
Spud Drilling Contractor: HILLER DRLG
Final Drill Date: 1984-08-13
Well Total Depth: 591.00 ft
Configuration: Vertical
Latitude: 40.890000
Longitude: -82.140000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1984-07-31 133 QUAKER STATE OIL REF CORP GeoDate 7/31/84
Enhanced Recovery 1984-07-31 Issued Date 7/31/84 Expired Date 1/27/85 Acres 0088500 Tool Type CT Proposed Formation BEREA Proposed Depth 00000 Proposed Drill Depth 00000
Original Spud 1984-07-31 CONVERT 8-4-84 IP. INJECTION WELL
Completed 1984-08-13 CONVERT 8-4-84 IP. INJECTION WELL
Reached Total Depth 1984-08-13 CONVERT 8-4-84 IP. INJECTION WELL
First Injection 1984-10-19 CONVERT 8-4-84 IP. INJECTION WELL
Completion Report Received 1984-12-07 CONVERT 8-4-84 IP. INJECTION WELL
Construction Permit Expires 1985-01-27 CONVERT 8-4-84 IP. INJECTION WELL
Annulus Pressure Monitoring Approved 1986-08-11 CONVERT 8-4-84 IP. INJECTION WELL
CO 1995-10-18 182 BELDEN & BLAKE CO GeoDate 7/31/84
Change of Owner 2002-02-07 Operator changed from 182, BELDEN & BLAKE CORPORATION to 2491, MILLER ROY/RA MILLER ENER
Change of Owner 2009-02-04 Operator changed from 2491, MILLER ROY/RA MILLER ENER to 8227, DEEP RESOURCES LLC
Last Compliance Report 2010-07-28 CONVERT 8-4-84 IP. INJECTION WELL
Record Last Modified 2017-02-15 CONVERT 8-4-84 IP. INJECTION WELL

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-05-22 552 594 0
2000-05-22 555 595 0
552 594 0
555 595 0
552 594 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
NITR 0 80 Qts 0 FOR PRODUCTION
NITR 0 65 Qts 0 FOR ERP

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 QUAKER STATE OIL REF CORP 0.00 71.00 0
2009 DERBY OPERATING CORP 199.00 66.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 QUAKER STATE OIL REF CORP Brine 0 0
2009 DERBY OPERATING CORP Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1012782420 2012-6-4 0:00:0 ER No Violations
-1056713503 2012-11-27 0:00 ER No Violations
-1084341275 2020-5-13 0:00: ER No Violations
-1110713878 2019-4-22 0:00: ER No Violations
-111914747 2018-4-12 0:00: ER No Violations
-1175768885 2015-11-2 0:00: ER No Violations
-1251370727 2015-9-29 0:00: WR No Violations
-125612612 2008-4-16 0:00: ER No Violations 1.00
-1263206997 2003-8-7 0:00:0 ER No Violations
-1382004694 2015-3-19 0:00: ER No Violations
-162623260 2004-11-17 0:00 ER No Violations
-171584398 2018-1-24 0:00: ER No Violations
-17868454 2019-1-9 0:00:0 ER No Violations
-1929853092 2012-2-27 0:00: ER No Violations
-1982173126 2013-10-29 0:00 ER No Violations
-2130710223 2010-12-14 0:00 ER No Violations 1.00
-276965363 2020-1-7 0:00:0 ER No Violations
-408546568 2016-5-9 0:00:0 ER No Violations
-430901501 2017-4-24 0:00: ER No Violations
-48979488 2017-7-13 0:00: ER No Violations
-559439536 2016-7-11 0:00: ER No Violations
-719076169 2007-10-4 0:00: ER No Violations 0.50
-719780744 2015-9-28 0:00: WR No Violations
-729646288 2015-9-23 0:00: ER No Violations
-746803910 2013-5-22 0:00: ER No Violations
-799507321 2010-7-20 0:00: ER No Violations 3.00
-815354806 2010-4-8 0:00:0 ER No Violations 0.50
-823438209 2016-1-6 0:00:0 ER No Violations
0004658984 2007-10-16 Enhanced Recovery Project No Violations Pulled 1 tubing and packer and replaced with new Larkin packer and pvc lined 1 tubing. Set packer at 530. Tested at 360 psi. NOV in compliance.
0048979488 2017-07-13 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0111914747 2018-04-12 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The operator has shut the well in. The main supply valve flow line needs to be repaired and replaced.
0125612612 2008-04-16 Enhanced Recovery Project No Violations Annulus and injection pressure test. Valve on annular side was split and leaking. Replaced valve and pressured up annulus to 200 psi. It is is holding at 190 psi. after 15 minute test .NOV in compliance. Flood water remains around well box. Sun, 50 degrees.
0128180576 2012-09-11 Enhanced Recovery Project No Violations Inspect Well. Site ok.
0162623260 2004-11-17 Enhanced Recovery Project No Violations Injection pressure test.
0171584398 2018-01-24 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0272253406 2016-11-01 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0336645642 2015-05-20 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Well is Shut in. Due to a leak.
0402702448 2006-12-19 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0408546568 2016-05-09 Enhanced Recovery Project No Violations Follow up inspection from April 25, 2016. The operator has replaced the fitting that were in poor condition.
0415990064 2017-01-30 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0430901501 2017-04-24 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0559439536 2016-07-11 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The well head fittings have recently been replaced.
0650587548 2005-04-27 Enhanced Recovery Project No Violations Injection well test.
0719076169 2007-10-04 Enhanced Recovery Project Violations Noted Injection and annulus pressure test. Pressures are equal and needs packer set. Shut in well.
0719780744 2015-09-28 Work Over Reconditioning No Violations The packer and tubing was removed from the well. A replacement packer was installed and the 21 Joints of PVC lined one inch tubing run into 525 feet.
0729646288 2015-09-23 Enhanced Recovery Project No Violations Inspect well with operator to pressure test annulus. The annulus did not pressure up above the formation pressure. The well requires service. The Service Rig #9 was moved onto the location for service.
0746803910 2013-05-22 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0799507321 2010-07-20 Enhanced Recovery Project No Violations Ran 1 tubing and packer to 530. Set packer and pressure would not hold. Advised Len Rex to trip out and clean 2 3/8 tubing or plug well.
0815354806 2010-04-08 Enhanced Recovery Project No Violations Injection and annulus pressure test. Pressures are equal at 350 psi. Reset packer and test.
0823438209 2016-01-06 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Annulus fitting was frozen due to cold weather.
0878910079 2014-03-17 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0898904371 2008-12-16 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0984869975 2013-03-05 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1012782420 2012-06-04 Enhanced Recovery Project No Violations Inspect Well.
1056713503 2012-11-27 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1094628654 2006-01-25 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1098636246 2014-08-18 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1100813747 2011-07-11 Enhanced Recovery Project No Violations inspect well.
1122925391 2014-10-28 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1156254560 2006-08-22 Enhanced Recovery Project No Violations Injection and annulus pressure test. Sun, 70 degrees
1170449190 2018-08-17 Surface Facility Construction No Violations Inspect well for integrity and pressure.
1175768885 2015-11-02 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The well head is in good condition.
1200454322 2009-04-27 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1207592976 2008-04-07 Enhanced Recovery Project Violations Noted Annulus presure is 0 psi. Pump up annular side to 200 psi.
1251370727 2015-09-29 Work Over Reconditioning No Violations The packer was run to 525 feet. Circulate fresh water with inhibitor in the annulus. Set packer in compression. Pressure test well to 370 psi and test for 15 minutes with no loss in pressure. Well passes Mechanical Integrity Test. Well is put in to injection production. Compliance notification of 8/27/2015 was resolved.
1263206997 2003-08-07 Enhanced Recovery Project No Violations ANNULUS AND INJECTION PRESSURE EQUALIZED, REQUESTED MINI-TEST TO DEMONSTRATE MIT
1275833102 2019-1-10 0:00: ER No Violations
1279711326 2010-07-16 Enhanced Recovery Project No Violations Pulled 1 tubing and packer. Replaced with Larkin rebuilt packer. After several pressure tests pressure would not hold. Tripped tubing and packer. Shut well in on 2 3/8 tubing
1280145113 2010-07-26 Enhanced Recovery Project No Violations Tripped out 1 tubing and packer and pressure tested each joint. Found a crack in one joint at threads. Replaced joint and ran in on packer. Tested annulus at 400 psi for 15 minutes and 0 psi drop. Compliance Notice approved. Mud, sun, 70 degrees.
128180576 2012-9-11 0:00: ER No Violations
1292526228 2010-12-16 Enhanced Recovery Project No Violations Replaced annular valve and tested at 250 psi. After 15 minutes pressure held at 245 psi. NOV in compliance.
1374457675 2014-05-06 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1382004694 2015-03-19 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The line valve to the well was shut during inspection, as a result of previous flow line repairs.
1394918411 2018-01-26 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1429942992 2015-08-27 Enhanced Recovery Project Violations Noted Inspect well for integrity and pressure. The annulus and the injection tubing have equalized. Pressure testing of well head annulus is required.
1442069623 2009-10-06 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1568815613 2019-9-9 0:00:0 ER No Violations
1670289897 2016-01-07 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Retest wellhead. Fittings have thawed out after freezing due to cold weather.
1771288809 2018-10-01 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1795219602 2017-10-18 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1859186409 2011-10-18 Enhanced Recovery Project No Violations Inspect well.
1929853092 2012-02-27 Enhanced Recovery Project No Violations inspect well.
1966784354 2016-04-25 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The nipple at the tee and elbow on injection line are in poor condition.
1982173126 2013-10-29 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
2012331189 2007-05-24 Enhanced Recovery Project No Violations Injection and annulus pressure test.
2130710223 2010-12-14 Enhanced Recovery Project Violations Noted Injection and annulus pressure test. Replace annulus side valve. Could not open to test. ERP# 13, W-4
272253406 2016-11-1 0:00: ER No Violations
336645642 2015-5-20 0:00: ER No Violations
340301038 2019-10-24 0:00 ER No Violations
402702448 2006-12-19 0:00 ER No Violations 0.50
415990064 2017-1-30 0:00: ER No Violations
418317231 2020-7-17 0:00: ER No Violations
4658984 2007-10-16 0:00 ER No Violations 5.00
650587548 2005-4-27 0:00: ER No Violations 0.50
878910079 2014-3-17 0:00: ER No Violations
898904371 2008-12-16 0:00 ER No Violations 0.50
984869975 2013-3-5 0:00:0 ER No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0719076169 US-OH-128167 2007-10-04 Failure to conduct or pass mech. integrity test
1207592976 US-OH-105429 2008-04-07 Failure to conduct or pass mech. integrity test
1429942992 US-OH-112576 2015-10-07 Failure to conduct or pass mech. integrity test
2130710223 US-OH-121837 2010-12-14 Failure to conduct or pass mech. integrity test

For data sources see[9]