Well Details

Well ID: 34-151-25198
Loading map...
Country: United States
State: Ohio
County: Stark
Municipality: Nimishillen Township
Operator Name: BECK ENERGY CORPORATION
Well Pad ID:
Farm/Lease Name: KLEPADLO
License Status: Producing
License Date: 2000-10-05
Spud Date: 2000-12-16
Spud Drilling Contractor: PEP DRLG
Final Drill Date: 2000-12-22
Well Total Depth: 4965.00 ft
Configuration: Vertical
Latitude: 40.860000
Longitude: -81.280000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2000-10-05 1888 BECK ENERGY CORP Proposed Formation CLINTON Issued Date 10/5/00 Expired Date 10/5/01 6:00:00 AM
Original Spud 2000-12-16 RBDMS Rec
Completed 2000-12-22 RBDMS Rec
Reached Total Depth 2000-12-22 RBDMS Rec
Completion Report Received 2001-08-30 RBDMS Rec
Construction Permit Expires 2001-10-05 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2001-10-23 4794 4836 45
4794 4836 45
4794 4836 45

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 99650 Gal 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2001 BECK ENERGY CORPORATION 5561.00 2050.00 258
2002 BECK ENERGY CORPORATION 5445.00 1563.00 365
2003 BECK ENERGY CORPORATION 3085.00 869.00 365
2004 BECK ENERGY CORPORATION 1818.00 663.00 365
2005 BECK ENERGY CORPORATION 1574.00 506.00 365
2006 BECK ENERGY CORPORATION 1162.00 322.00 365
2007 BECK ENERGY CORPORATION 963.00 518.00 365
2008 BECK ENERGY CORPORATION 1210.00 681.00 365
2009 BECK ENERGY CORPORATION 641.00 514.00 365
2010 BECK ENERGY CORPORATION 1329.00 125.00 365
2011 BECK ENERGY CORPORATION 1350.00 556.00 365
2012 BECK ENERGY CORPORATION 857.00 609.00 366
2013 BECK ENERGY CORPORATION 632.00 474.00 365
2014 BECK ENERGY CORPORATION 746.00 444.00 365
2015 BECK ENERGY CORPORATION 419.00 243.00 365
2016 BECK ENERGY CORPORATION 1018.00 251.00 365
2017 BECK ENERGY CORPORATION 946.00 380.00 365
2018 BECK ENERGY CORPORATION 784.00 333.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2001 BECK ENERGY CORPORATION Brine 1854 258
2002 BECK ENERGY CORPORATION Brine 560 365
2003 BECK ENERGY CORPORATION Brine 35 365
2004 BECK ENERGY CORPORATION Brine 20 365
2005 BECK ENERGY CORPORATION Brine 35 365
2006 BECK ENERGY CORPORATION Brine 0 365
2007 BECK ENERGY CORPORATION Brine 100 365
2008 BECK ENERGY CORPORATION Brine 210 365
2009 BECK ENERGY CORPORATION Brine 70 365
2010 BECK ENERGY CORPORATION Brine 65 365
2011 BECK ENERGY CORPORATION Brine 110 365
2012 BECK ENERGY CORPORATION Brine 270 366
2013 BECK ENERGY CORPORATION Brine 115 365
2014 BECK ENERGY CORPORATION Brine 196 365
2015 BECK ENERGY CORPORATION Brine 46 365
2016 BECK ENERGY CORPORATION Brine 0 365
2017 BECK ENERGY CORPORATION Brine 128 365
2018 BECK ENERGY CORPORATION Brine 95 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1560592073 2009-4-30 0:00: PW No Violations
-232677184 2017-8-16 0:00: PW No Violations 0.50
-932658779 2010-7-28 0:00: PW No Violations
0001288i66 2001-09-25 Preliminary Restoration No Violations Preliminary restoration approved , no violations at this time . Spud date : 12/16/00.
001288i459 2002-04-15 Preliminary Restoration No Violations Preliminary restoration approved at this time . No violations at this time .
0232677184 2017-08-16 Production Wells No Violations I did a status check inspection on this well. The well is equipped with a pumpjack with a gas motor. There is a domestic gas connection at the well. The tank battery consists of a steel production tank, two plastic brine tanks, a horizontal separator and a meter. The well is legibly identified. The well and tank battery are fenced in with locked gates. There are no compliance issues note at this time.
0932658779 2010-07-28 Production Wells Violations Noted I received a call from Jr. Bargerhoff (Beck Energy) reporting a brine and crude oil release from a cracked and broken 36 bbl plastic brine tank. Approximately 35 bbls of brine and 1 bbl of crude oil were released into the tank battery dike when the brine tank cracked and split open when a water truck driver connected to the tank to drain off the brine. The remediation was in progress when I arrived to inspect the site. I met with Jr. Bargerhoff on the site and discussed the remediation. The contaminated soil is being dug out and removed from the site. The plastic brine tank was 7 years old.
1074106082 2004-01-14 Production Wells No Violations NO VIOLATIONS. GPS WH and TB (1-210 bbl. oil, 2-40 bbl. brine).
1239838854 2009-04-16 Production Wells No Violations The Uniontown office received a complaint call on 4-15-2009 from Chris Miculan (330-413-4146) at 5885 Shannon Ave. regarding pollution and contamination at the wellhead; excessive noise from the pumping unit; noise from an oil tanker on the location at midnight, and children playing near the pumping unit. I inspected the location today and found no violations at the wellhead or at the tank battery. I called Dave Beck (Beck Energy) and informed him that the pumping unit and the tank battery needed to be fenced and that the pumping unit needed to be greased. I called Chris Miculan and informed him of my inspection.
1288i459 2002-4-15 0:00: PL No Violations 0.50
1288i66 2001-9-25 0:00: PL No Violations 0.50
1407030503 2010-08-04 Production Wells No Violations The brine release has been remediated and the tank battery dike has been restored. The Compliance Notice has been RESOLVED.
1560592073 2009-04-30 Production Wells No Violations Beck Energy has complied with my request. The pumping unit and the tank battery have been fenced with an 8 high chain link fence with 3 strands of barbed wire along the top. Locks have been placed on the gated openings. The complaint is RESOLVED.
2124061398 2015-09-29 Production Wells No Violations I was on location to perform an inspection of this production well. The lease road is gravel and stable. The tank battery is surrounded by a fence and contains a dike, 210bbl production tank, two (2) poly brine tanks horizontal separator and a chart box. The pumpjack is gas driven, has a house gas connection and is surrounded by a fence. The fences are locked and tank battery is properly identified. There are no violations at this time.
iDIAN00627 2001-09-25 Preliminary Restoration No Violations
iDIAN006274 2001-9-25 0:00: PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0932658779 US-OH-130661 2010-07-28 Well operation causing pollution and contamination