34-031-24301

Well Details

Well ID: 34-031-24301
Loading map...
Country: United States
State: Ohio
County: Coshocton
Municipality: Bethlehem Township
Operator Name: BRILEX LLC
Well Pad ID:
Farm/Lease Name: SPECKMAN JAMES & LUELLA
License Status: Producing
License Date: 1992-06-26
Spud Date: 1992-10-09
Spud Drilling Contractor: [[JL COATS [COATS-GOFF]]]
Final Drill Date: 1992-10-18
Well Total Depth: 3633.00 ft
Configuration: Vertical
Latitude: 40.310000
Longitude: -81.930000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1982-12-06 Issued Date 12/6/82 Expired Date 6/4/83 Acres 0020000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
CO 1983-06-15 184 OHIO NATURAL FUEL CO GeoDate 6/15/83
Oil and Gas 1983-06-15 Issued Date 6/15/83 Expired Date 12/12/83 Acres 0020000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
CO 1983-11-17 184 OHIO NATURAL FUEL CO GeoDate 11/17/83
Oil and Gas 1983-11-17 Issued Date 11/17/83 Expired Date 5/15/84 Acres 0020000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
CO 1992-06-26 278 PRICE GREGG CORP GeoDate 6/26/92
Oil and Gas 1992-06-26 Issued Date 6/26/92 Expired Date 6/26/93 Acres 0020000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 03633 Proposed Drill Depth 03633
Original Spud 1992-10-09 R.I. 6-18-83, R.I. 11-19-83, R.I. 6-27-92 PERMIT EXPIRED
Completed 1992-10-18 R.I. 6-18-83, R.I. 11-19-83, R.I. 6-27-92 PERMIT EXPIRED
Reached Total Depth 1992-10-18 R.I. 6-18-83, R.I. 11-19-83, R.I. 6-27-92 PERMIT EXPIRED
CO 1992-11-18 184 OHIO NATURAL FUEL CO GeoDate 12/6/82
Completion Report Received 1992-12-02 R.I. 6-18-83, R.I. 11-19-83, R.I. 6-27-92 PERMIT EXPIRED
Construction Permit Expires 1993-06-26 R.I. 6-18-83, R.I. 11-19-83, R.I. 6-27-92 PERMIT EXPIRED
Change of Owner 2014-07-21 Operator changed from 278, PRICE GREGG CORP to 9252, BRILEX LLC
Record Last Modified 2017-02-15 R.I. 6-18-83, R.I. 11-19-83, R.I. 6-27-92 PERMIT EXPIRED

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3454 3532 0
3454 3532 0
2006-09-11 3526 3532 7
3526 3532 7
3454 3532 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 0 0 FRAC...WATER/SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2001 GREGG PRICE CORP 168.00 9.00 365
2002 GREGG PRICE CORP 174.00 0.00 365
2003 GREGG PRICE CORP 89.00 0.00 365
2004 GREGG PRICE CORP 228.00 16.00 365
2005 GREGG PRICE CORP 165.00 17.00 365
2006 GREGG PRICE CORP 162.00 0.00 365
2007 GREGG PRICE CORP 217.00 14.00 365
2008 GREGG PRICE CORP 403.00 0.00 365
2009 GREGG PRICE CORP 493.00 9.00 365
2010 GREGG PRICE CORP 281.00 0.00 365
2011 GREGG PRICE CORP 383.00 5.00 365
2012 GREGG PRICE CORP 338.00 0.00 366
2013 GREGG PRICE CORP 226.00 7.00 365
2014 GREGG PRICE CORP 30.00 0.00 365
2015 BRILEX LLC 108.00 12.00 365
2016 BRILEX LLC 233.00 0.00 365
2017 BRILEX LLC 291.00 9.00 365
2018 BRILEX LLC 135.00 20.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2001 GREGG PRICE CORP Brine 0 365
2002 GREGG PRICE CORP Brine 0 365
2003 GREGG PRICE CORP Brine 0 365
2004 GREGG PRICE CORP Brine 0 365
2005 GREGG PRICE CORP Brine 0 365
2006 GREGG PRICE CORP Brine 0 365
2007 GREGG PRICE CORP Brine 0 365
2008 GREGG PRICE CORP Brine 0 365
2009 GREGG PRICE CORP Brine 0 365
2010 GREGG PRICE CORP Brine 0 365
2011 GREGG PRICE CORP Brine 0 365
2012 GREGG PRICE CORP Brine 0 366
2013 GREGG PRICE CORP Brine 0 365
2014 GREGG PRICE CORP Brine 0 365
2015 BRILEX LLC Brine 0 365
2016 BRILEX LLC Brine 0 365
2017 BRILEX LLC Brine 2 365
2018 BRILEX LLC Brine 3 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1100187271 2009-1-21 0:00: PW No Violations
-1225722936 2008-10-22 0:00 PW No Violations
-1432074561 2004-10-19 0:00 PW No Violations
-1546927826 2017-4-7 0:00:0 PW No Violations 0.70
-1552111923 2008-12-22 0:00 PW No Violations
-1559622469 2016-2-29 0:00: PW No Violations 0.50
-21357361 2002-12-11 0:00 PW No Violations
-263516307 2017-9-18 0:00: PW No Violations
-574406740 2008-11-19 0:00 PW No Violations
-93421227 2013-4-3 0:00:0 PW No Violations
0021357361 2002-12-11 Production Wells Violations Noted FOLLOW UP TO NOV # 253667763 no id at well head, id needs placed at well head . Notified Mark Clark by phone 2/6/04 to have ids posted within 30 days . Called Mark Clarke 4/27/04 requested 2 week extension . 7/30/04 Storage tank id no id at well head
0093421227 2013-04-03 Production Wells No Violations On the day of my inspection I found that the well head was equipped with a plunger lift system and connected to a tank battery that consisted of one 140 barrel stock tank, one 70 barrel brine tank, one separator and an earthen dike. Proper identification was posted and there were no leaks or spills. This well shares a tank battery with permits 4243, 4245, 4302, 4303 and 4304. No violations at this time.
0253667763 2002-12-11 Production Wells Violations Noted no id at well head, id needs placed at well head . Notified Mark Clark by phone 2/6/04 to have ids posted within 30 days . Called Mark Clarke 4/27/04 requested 2 week extension . 7/30/04 Storage tank id no id at well head . COMPLIANCE 10/19/04 ID POSTED
0263516307 2017-09-18 Production Wells No Violations On the day of my inspection I found that the weeds had all been trimmed down around the production equipment. The identification sign has been filled out with the correct, complete information. The section of steel line at the separator had been replaced and the oil residue had been cleaned up. There was no gas venting from the tank and no other leaks around the equipment.
0564965428 2004-07-30 Production Wells No Violations 7/30/04 Storage tank id no id at well head .
0574406740 2008-11-19 Production Wells No Violations Took picture of well , well isnt in production , valve at well head is shot in . Identification hasnt been posted . Request permit hold list for company .
0940053144 2003-10-27 Production Wells No Violations Non compliance for well head identification . Request permit hold list .
1054225936 2003-05-29 Preliminary Restoration No Violations pasted
1100187271 2009-01-21 Production Wells No Violations Well capable of production . Compliance for idle well . Well head is identified
1225722936 2008-10-22 Production Wells Violations Noted No identification at well head , well is using common storage tank site . 2 Valve in lead line at well head is shut , well is not in production . Hand delivered to Mark Clarke
1432074561 2004-10-19 Production Wells No Violations COMPLIANCE 10/19/04 ID POSTED
1505739838 2017-09-15 Production Wells No Violations I got a phone call from Mike Snyder, Fire Chief with Walhonding Valley Fire Department, to notify me of multiple calls to the dispatch in regards to the production equipment for the Speckman lease. Mike said that they had been getting calls for two days claiming that smoke was rising out of the storage tank. He said that they went out to the site and found gray smoke rising out of the tank, as well as oil spraying out of one of the lines at the separator. He said that they tried to call the number on the identification sign and got no answer. He also made a comment about the appearance of the site with regards to weed control, as the tank is located next to US 36. I called Frank Riggle and Rob Hunter with Brilex and relayed the Chiefs concerns. They said that they would get out to the site right away. When I arrived, Frank and Rob were already there. They said that the dump valve on the separator had failed, causing the gas to vent out of the tank, giving the appearance of smoke. The oil spray was due to a pin hole in one of the flow lines at the separator and resulted in an oil spray that got on the gravel and in the perimeter weeds. There was no pooled oil on the ground. The amount of oil was less than one gallon. Rob and Frank had the system shut in. They were replacing the section of line that failed and attending to the dump valve. Rob spread Bio-sorb on the oily gravel and the weeds. He also used a power trimmer to start clearing the weeds away from the containment dike. The number on the ID sign was Franks cell phone number, which is a working number. The DI sign did need to be filled out with the individual well information though. The situation was under their control. The gas was no longer venting and the oil spray had ceased. I left Rob and Frank to clean the site up and will follow up on Monday.
1546927826 2017-04-07 Production Wells No Violations On the day of my inspection I found that the wellhead was equipped with a plunger lift system. The flow line was connected and the tubing valve was open. There were no leaks at the wellhead. The tank battery consisted of one 140 barrel steel tank, one 70 barrel steel tank and one horizontal separator in an earthen dike. There were no leaks or spills around the production equipment. The tank battery is shared with permits 4302, 4303, 4304, 4243 and 4245. Identification signs were posted at the tank battery and at the wellheads, but they were all blank. I met Frank Riggle in the field and spoke with him about getting all of the ID signs correctly filled out. He said that they would get it taken care of.
1552111923 2008-12-22 Production Wells No Violations ID posted , well shut in .
1559622469 2016-02-29 Production Wells No Violations On the day of my inspection I found that the wellhead was equipped with a plunger lift system. The tubing valve was open. The tank battery consisted of one 140 barrel steel tank, one 70 barrel steel tank, one separator and an earthen dike. The tank battery is shared with permits 4302, 4303, 4304, 4243 and 4245. Identification was posted at the tank battery and at the wellhead. I found no leaks or spills.
253667763 2002-12-11 0:00 PW No Violations
564965428 2004-7-30 0:00: PW No Violations
940053144 2003-10-27 0:00 PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0021357361 US-OH-121895 2002-12-11 Failure to legibly identify well
0253667763 US-OH-122614 2002-12-11 Failure to legibly identify well
1225722936 US-OH-106076 2008-10-22 Failure to legibly identify well

For data sources see[9]

References