34-151-25541

Well Details

Well ID: 34-151-25541
Loading map...
Country: United States
State: Ohio
County: Stark
Municipality: Washington Township
Operator Name: C & T ENERGY OF EAST CANTON IN
Well Pad ID:
Farm/Lease Name: WARNER-TRUMMER-SCHULTZ UNIT
License Status: Producing
License Date: 2006-12-20
Spud Date: 2007-01-02
Spud Drilling Contractor: ADVENT DRLG
Final Drill Date: 2007-01-07
Well Total Depth: 5303.00 ft
Configuration: Vertical
Latitude: 40.870000
Longitude: -81.140000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-12-20 Proposed Formations:CLINTON, Issued Date:12/20/2006, Expired Date:12/20/2007 6:00:00 AM, Drilling unit acres:120, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2007-01-07
Reached Total Depth 2007-01-07
Completion Report Received 2007-02-12
Construction Permit Expires 2007-12-20
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-05-16 5085 5168 58
5085 5168 58
5085 5168 58

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 196000 Gal 100000 1000 GALLONS FE ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 C & T ENERGY OF EAST CANTON IN 12968.00 864.00 365
2008 C & T ENERGY OF EAST CANTON IN 11023.00 872.00 365
2009 C & T ENERGY OF EAST CANTON IN 5872.00 384.00 365
2010 C & T ENERGY OF EAST CANTON IN 5190.00 247.00 365
2011 C & T ENERGY OF EAST CANTON IN 5035.00 237.00 0
2012 C & T ENERGY OF EAST CANTON IN 4222.00 146.00 366
2013 C & T ENERGY OF EAST CANTON IN 5433.00 157.00 365
2014 C & T ENERGY OF EAST CANTON IN 2883.00 67.00 365
2015 C & T ENERGY OF EAST CANTON IN 4033.00 163.00 365
2016 C & T ENERGY OF EAST CANTON IN 4020.00 192.00 365
2017 C & T ENERGY OF EAST CANTON IN 3948.00 112.00 365
2018 C & T ENERGY OF EAST CANTON IN 3828.00 113.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 C & T ENERGY OF EAST CANTON IN Brine 3380 365
2008 C & T ENERGY OF EAST CANTON IN Brine 2115 365
2009 C & T ENERGY OF EAST CANTON IN Brine 1710 365
2010 C & T ENERGY OF EAST CANTON IN Brine 1120 365
2011 C & T ENERGY OF EAST CANTON IN Brine 200
2012 C & T ENERGY OF EAST CANTON IN Brine 70 366
2013 C & T ENERGY OF EAST CANTON IN Brine 100 365
2014 C & T ENERGY OF EAST CANTON IN Brine 23 365
2015 C & T ENERGY OF EAST CANTON IN Brine 385 365
2016 C & T ENERGY OF EAST CANTON IN Brine 162 365
2017 C & T ENERGY OF EAST CANTON IN Brine 105 365
2018 C & T ENERGY OF EAST CANTON IN Brine 70 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-41926409 2019-1-7 0:00:0 PW No Violations 1.10
-639936291 2009-4-23 0:00: PW No Violations
0041926409 2019-01-07 Production Wells No Violations Prior to my inspection for Complaint #6049, I called and left a message for the complainant on 12-27-18 after receiving a notification from Sharmon Hughes (Oil & Gas Admin). I did not receive a return call at that time. I called and left a message for complainant on 01-07-2019. The complainant returned my call and advised me he had been previously smelling a strong odor of gas from the tank battery located west of his residence. My inspection found the well equipped with a pumpjack. The well and tank battery have domestic gas connections. The tank battery consists of two steel production tank and a vertical separator. The tank battery is shared with well #25540. The well is legibly identified. There was no odor of gas at the time of my inspection. I spoke with Paul Shaw (Dorfman) he advised the separator dump valve was replaced the previous week. I called and spoke with Mr. Clark about my findings and he advised me he had not smelled the gas odor for a while. I gave Mr. Clark my contact number and advised him to call me anytime he had concerns about the well. I am recommending complaint #6049 be closed. No compliance issues were cited at this time.
0460164528 2007-09-28 Preliminary Restoration No Violations The well is completed as a pumping well. The location is reclaimed. The tank battery (1-shared 140 bbl oil stock tank, 1-shared 100 bbl brine tank) and the wellhead have the correct I.D. signs. The Preliminary Restoration is PASSED.
0639936291 2009-04-23 Production Wells No Violations I met with Steve Clark (330-701-7852) at 4000 Beechwood Ave., Alliance, OH, regarding the new charcoal filter that has been placed on the stock tank at the tank battery that is located west of his home. He said that the odor has decreased and his dogs are no longer getting sick. However, Steve has been diagnosed with leukemia resulting from benzene poisoning. I suggested that he call the Stark County Health Dept. in regard to his medical condition. I called Greg New and informed him of Steve Clarks condition.
0773581038 2007-01-04 Drill / Deepen / Reopen No Violations Cemented surface casing this morning. Waiting on cement. Pits and liners are intact.
1238527368 2009-03-31 Production Wells No Violations I received a complaint call on 3-30-2009 from Steve Clark (330-701-7852) at 4000 Beechwood Ave., Alliance, OH, regarding a strong gas odor coming from the tank battery that is located west of his home. He said that gas keeps blowing from the separator and that he has been sick for 10 months and is getting checked for methane poisoning. I called Greg New who is taking care of this well for Cathy Lesher (C & T Energy) and discussed the complaint. On 3-31-2009, I inspected the tank battery. There was no gas leak observed at the separator. Gas was observed venting from the 2 dia vent pipe located on the oil stock tank. I called Greg New and requested that he place a charcoal filter on the vent pipe. I called Steve Clark and informed him of my inspection and recommendations.
1240235115 2009-04-17 Production Wells No Violations See Complaint #09-001. The charcoal filter has been placed on the stock tank. The complaint has been RESOLVED.
1242505406 2009-05-15 Production Wells No Violations I received a complaint call at 0845 hrs from Steve Clark (330-701-7852) at 4000 Beechwood Ave., Alliance, OH, regarding the odor at the stock tank at the tank battery that is located west of his home. He said that the odor has increased and that he has a headache and his dogs are getting sick. I called Greg New and requested that he send the pumper out to check the separator and the charcoal filter. Greg called me back and said that the separator dump valve was stuck open and that the charcoal filter was plugged. The problem was resolved. I called Steve Clark at 1120 hrs and informed him that the problem was resolved. Steve was at the hospital getting checked for his health concerns.
1699812640 2017-10-26 Production Wells No Violations I did a status check inspection for this well. The well is equipped with a pumpjack. The tank battery consists of two steel production tank, and a vertical separator. There is a domestic gas connection at the tank battery. The tank battery is shared with well #151-25540. The well is legibly identified. No compliance issues are noted at this time.
  • The tank Battery is located on Beechwood Ave. ~ 1/2 mile North of Bayton St. on the left side.*
1791145408 2009-04-23 Production Wells No Violations There were no violations at the wellhead or at the tank battery.
460164528 2007-9-28 0:00: PL No Violations
773581038 2007-1-4 0:00:0 DD No Violations

For data sources see[9]

References