If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-151-25844 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.75,"lon":-81.13,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Stark | |
Municipality: Paris Township | |
Operator Name: C & T ENERGY OF EAST CANTON IN | |
Well Pad ID: | |
Farm/Lease Name: EVANICH | |
License Status: Producing | |
License Date: 2013-10-15 | |
Spud Date: 2013-10-15 | |
Spud Drilling Contractor: | |
Final Drill Date: 2013-10-23 | |
Well Total Depth: | |
Configuration: Vertical | |
Latitude: 40.750000 | |
Longitude: -81.130000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2013-10-15 | Proposed Formations:CLINTON, Issued Date:10/15/2013, Expired Date:10/15/2015 12:00:00 PM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2013-10-23 | STATUS BASED ON PRODUCTION FILING 2013- |
Construction Permit Expires | 2015-10-15 | STATUS BASED ON PRODUCTION FILING 2013- |
Completion Report Received | 2017-07-17 | STATUS BASED ON PRODUCTION FILING 2013- |
Record Last Modified | 2017-10-23 | STATUS BASED ON PRODUCTION FILING 2013- |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2017-07-31 | 5170 | 5233 | 56 |
5170 | 5233 | 56 | |
5170 | 5233 | 56 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2013-11-04 | H2O | 15 | 131000 Gal | 80000 | Superior Well Services | STAGE 1 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2013 | C & T ENERGY OF EAST CANTON IN | 0.00 | 0.00 | 0 |
2014 | C & T ENERGY OF EAST CANTON IN | 3557.00 | 2936.00 | 365 |
2015 | C & T ENERGY OF EAST CANTON IN | 2427.00 | 1406.00 | 365 |
2016 | C & T ENERGY OF EAST CANTON IN | 1640.00 | 957.00 | 365 |
2017 | C & T ENERGY OF EAST CANTON IN | 1257.00 | 788.00 | 365 |
2018 | C & T ENERGY OF EAST CANTON IN | 1252.00 | 693.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2013 | C & T ENERGY OF EAST CANTON IN | Brine | 1192 | 0 |
2014 | C & T ENERGY OF EAST CANTON IN | Brine | 1610 | 365 |
2015 | C & T ENERGY OF EAST CANTON IN | Brine | 595 | 365 |
2016 | C & T ENERGY OF EAST CANTON IN | Brine | 385 | 365 |
2017 | C & T ENERGY OF EAST CANTON IN | Brine | 210 | 365 |
2018 | C & T ENERGY OF EAST CANTON IN | Brine | 280 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-291863710 | 2018-2-13 0:00: | PW | No Violations | 0.50 |
-616162529 | 2018-1-18 0:00: | PW | No Violations | 0.70 |
0291863710 | 2018-02-13 | Production Wells | No Violations | I did a compliance follow-up inspection for this well. The well is legibly identified at the well and tank battery. The violation is passed. |
0616162529 | 2018-01-18 | Production Wells | Violations Noted | I did a status check inspection for this well. The well is equipped with a pumpjack. The tank battery consists of a steel production tank, a steel brine tank, a vertical separator and a meter. The tank battery is shared with well #151-25852. The well is not legibly identified at the wellhead. I called and spoke with Cathy (C & T Energy) she advised me she would have the pumper add a sign at the wellhead location. I will follow-up to check compliance during the week of 02-05-2018. |
1382450812 | 2013-10-17 | Casing String Witnessed | No Violations | I was onsite to witness the cementing of the 11.75 surface casing that was set to 627. A total of 350sks of 15.6ppg cement was pumped and 15 barrels of cement were returned to surface. |
1382620561 | 2013-10-23 | Drill / Deepen / Reopen | No Violations | I was on location to check the status of the well. Currently the well has hit TD and has had production casing cemented. A crew was onsite to run a bond log and several other logs. Advent drilling at this time is unsure of there next well, depending on when permits are released. |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0616162529 | US-OH-126961 | 2018-02-23 | 9-9-05(A)10 | Failure to legibly identify well |