X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-169-20269

Well Details

Well ID: 34-169-20269
Loading map...
Country: United States
State: Ohio
County: Wayne
Municipality: Clinton Township
Operator Name: COLUMBIA GAS TRANSMISSION LLC
Well Pad ID:
Farm/Lease Name: MILLER HETTIE
License Status: Storage Well
License Date:
Spud Date:
Spud Drilling Contractor:
Final Drill Date: 1942-11-05
Well Total Depth: 3074.00 ft
Configuration: Vertical
Latitude: 40.670000
Longitude: -82.120000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Completed 1942-11-05 GL=1114.0 SECT 24W FDT=CLINTON
Reached Total Depth 1942-11-05 GL=1114.0 SECT 24W FDT=CLINTON
Record Last Modified 2013-04-10 GL=1114.0 SECT 24W FDT=CLINTON

For data sources see[2]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2001 COLUMBIA GAS TRANSMISSION LLC 0.00 0.00 0
2002 COLUMBIA GAS TRANSMISSION LLC 0.00 0.00 0
2003 COLUMBIA GAS TRANSMISSION LLC 0.00 0.00 0
2004 COLUMBIA GAS TRANSMISSION LLC 0.00 0.00 0
2005 COLUMBIA GAS TRANSMISSION LLC 0.00 0.00 0
2006 COLUMBIA GAS TRANSMISSION LLC 0.00 0.00 0

For data sources see[3] [4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2001 COLUMBIA GAS TRANSMISSION LLC Brine 0 0
2002 COLUMBIA GAS TRANSMISSION LLC Brine 0 0
2003 COLUMBIA GAS TRANSMISSION LLC Brine 0 0
2004 COLUMBIA GAS TRANSMISSION LLC Brine 0 0
2005 COLUMBIA GAS TRANSMISSION LLC Brine 0 0
2006 COLUMBIA GAS TRANSMISSION LLC Brine 0 0

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1438743094 2017-4-14 0:00: SO No Violations
-618173706 2019-1-28 0:00: SO No Violations
0189550498 2014-03-20 Storage Well No Violations This is a gas storage well. There are no apparent problems at this time.
0618173706 2019-01-28 Storage Well No Violations Performed annual inspection for Columbia Gas Storage Well #7250 on 01/28/2019. The well is equipped with a flanged wellhead with 1-master valve and 1-wing valve, and a drip. Well identification is clearly displayed. No problems were noted at the time of the inspection.
0771623593 2013-04-04 Storage Well No Violations I inspected Columbia Gas Transmission gas storage well #7250 today. The well is located in the Wayne Storage Field, Clinton Township, Wayne County, Ohio. The well is equipped with a main valve, a side valve and is plumbed with a 3.00 line from the side valve to a drip tank. There is a 1.00 line plumbed from the drip tank to a 5 BBL storage tank. All lids and hatches are closed and secure. The storage tank is contained within an earthen dike sufficient to meet the requirements of 1501-9-9-05. The well is properly identified with a clear, legibly marked well identification sign mounted on the drip tank. No violations found.
0954952692 2015-02-13 Storage Well No Violations This is a storage well. No problems are apparent at this time.
0983730733 2018-02-01 Storage Well No Violations Performed annual inspection for Columbia Gas Storage Well #7250 on 02/01/2018. The well is equipped with a flanged wellhead with 1-master valve and 1-wing valve, and a drip. Well identification is clearly displayed. The well is located ~400 from its RBDMS location. No problems were noted at the time of the inspection.
1438743094 2017-04-14 Storage Well No Violations Performed annual inspection for Columbia Gas Storage Well #7250 on 04/14/2017. The well is equipped with a flanged wellhead with 1-master valve and 1-wing valve, and a drip tank. Well identification is clearly displayed. The well is located ~400 from its RBDMS location. No other problems were noted at the time of the inspection.
189550498 2014-3-20 0:00: SO No Violations 0.50
2084857994 2007-05-17 Work Over Reconditioning No Violations Arrived and waited on Cement trucks and water trucks and rig crew and never did get to set cement due to casing problem .return and wait again for next repair and still did not have time set, as to when casing cound be cemented . Did not witness after all of this
771623593 2013-4-4 0:00:0 SO No Violations
796481974 2020-1-8 0:00:0 SO No Violations
954952692 2015-2-13 0:00: SO No Violations 0.50
983730733 2018-2-1 0:00:0 SO No Violations

For data sources see[7]