Well ID: 34-153-20521 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.94,"lon":-81.57,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: DOMINION EAST OHIO | |
Well Pad ID: | |
Farm/Lease Name: STUMP MR & HJ | |
License Status: Storage Well | |
License Date: 1975-07-23 | |
Spud Date: 1975-08-19 | |
Spud Drilling Contractor: | |
Final Drill Date: 1975-08-29 | |
Well Total Depth: 4110.00 ft | |
Configuration: Vertical | |
Latitude: 40.940000 | |
Longitude: -81.570000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1975-07-23 | 240 EAST OHIO GAS CO GeoDate 7/23/75 |
Original Spud | 1975-08-19 | STORAGE-56, QUAD=MASSILLON, GL=1063.9, KB=1069.9 |
Completed | 1975-08-29 | STORAGE-56, QUAD=MASSILLON, GL=1063.9, KB=1069.9 |
Reached Total Depth | 1975-08-29 | STORAGE-56, QUAD=MASSILLON, GL=1063.9, KB=1069.9 |
Record Last Modified | 2009-12-11 | STORAGE-56, QUAD=MASSILLON, GL=1063.9, KB=1069.9 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 3969 | 3971 | 3 |
2006-09-11 | 3977 | 3979 | 3 |
3969 | 3971 | 3 | |
3969 | 3971 | 3 | |
2006-09-11 | 4007 | 4013 | 18 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 0 | 22000 | & ACID |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2002 | DOMINION EAST OHIO | 0.00 | 0.00 | 0 |
2003 | DOMINION EAST OHIO | 0.00 | 0.00 | 0 |
2004 | DOMINION EAST OHIO | 0.00 | 0.00 | 0 |
2005 | DOMINION EAST OHIO | 0.00 | 0.00 | 0 |
2006 | DOMINION EAST OHIO | 0.00 | 0.00 | 0 |
2007 | DOMINION EAST OHIO | 0.00 | 0.00 | 0 |
2008 | DOMINION EAST OHIO | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2002 | DOMINION EAST OHIO | Brine | 0 | 0 |
2003 | DOMINION EAST OHIO | Brine | 0 | 0 |
2004 | DOMINION EAST OHIO | Brine | 0 | 0 |
2005 | DOMINION EAST OHIO | Brine | 0 | 0 |
2006 | DOMINION EAST OHIO | Brine | 0 | 0 |
2007 | DOMINION EAST OHIO | Brine | 0 | 0 |
2008 | DOMINION EAST OHIO | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1343869098 | 2014-10-8 0:00: | SO | No Violations | 0.30 |
-1860492584 | 2015-6-29 0:00: | SO | No Violations | |
-281374701 | 2017-9-21 0:00: | SO | No Violations | |
-367815719 | 2019-10-8 0:00: | SO | No Violations | 0.30 |
-939303981 | 2013-3-5 0:00:0 | SO | No Violations | |
0091641631 | 2018-07-09 | Storage Well | No Violations | I did a status check inspection for this storage well. The well is equipped with a master gate valve, two side gate valves and a meter run. The diked tank battery consists of a steel tank. The well is legibly identified. No compliance issues are cited at this time. |
0281374701 | 2017-09-21 | Storage Well | No Violations | At the time of this inspection, the well site is equipped with:
|
0939303981 | 2013-03-05 | Storage Well | No Violations | I inspected Dominion East Ohio Gas storage well # 3271 today. The well is located in Section 22, Franklin Township, Summit County, Ohio. The well is equipped with a master gate, a side gate with a 4.00 Daniels run plumbed directly into the main pipeline. There is a flow gate with a 3.00 line plumbed into a 100 BBL storage tank. All lids and hatches are closed and secure. There are two (2) pickup lines on the storage tank and they are secured with valves and bullhead plugs in place. The well has an electronic control device mounted on the Daniels run to facilitate Dominion East Ohio Gas to remotely monitor the well. The well is properly identified with a clear, legibly marked well identification sign mounted on the storage tank. No violations found. |
0944814941 | 2016-08-11 | Storage Well | No Violations | I conducted a status check on this well. The well site is equipped with:
|
1343869098 | 2014-10-08 | Storage Well | No Violations | I inspected Dominion East Ohio Gas storage well #3271. The well is equipped with a master gate valve and a side gate valve. There is a flow gate valve plumbed with a 3.00 line into a 100 BBL storage tank. All lids and hatches on the storage tank are closed and secure. There are two (2) pickup lines on the storage tank and they are secured with valves and bull plugs in place. The tank battery is diked. The well is properly identified with a clear, legibly marked well identification sign mounted on the storage tank. The lease road is stoned and drivable. No violations found. |
1860492584 | 2015-06-29 | Storage Well | No Violations | I conducted a status check on this well. The well is equipped with a master gate valve and a side gate valve. There is a flow gate valve plumbed with a 3.00 line into a 100 BBL storage tank. All lids and hatches on the storage tank are closed and secure. There are two (2) tank drains on the storage tank and they are secured with valves and bull plugs in place. There is a mechanical separator. The tank battery is diked. The well is properly identified with a clear, legibly marked well identification sign mounted on the storage tank. The lease road is stable and drivable. No violations found. |
2013744953 | 2020-3-18 0:00: | SO | No Violations | 0.50 |
91641631 | 2018-7-9 0:00:0 | SO | No Violations | 0.50 |
944814941 | 2016-8-11 0:00: | SO | No Violations |