34-169-22087

Well Details

Well ID: 34-169-22087
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: SANDY SUPPLY CO
Well Pad ID:
Farm/Lease Name: SANDY SUPPLY
License Status: Final Restoration
License Date: 2012-04-27
Spud Date: 1979-04-11
Spud Drilling Contractor:
Final Drill Date: 1979-04-17
Well Total Depth: 3220.00 ft
Configuration: Vertical
Latitude: 40.790000
Longitude: -81.950000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1979-04-11
Completed 1979-04-17
Reached Total Depth 1979-04-17
APP 2012-04-27 Proposed Formations:CLINTON, Issued Date:4/27/2012, Expired Date:4/27/2014 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2012-09-27
Record Last Modified 2013-08-16
Construction Permit Expires 2014-04-27

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 3097 3101 2
2006-09-11 3108 3112 0
3097 3101 2
3097 3101 2
2006-09-11 3146 3150 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 55000 Gal 0 600 SKS. SAND
N2 0 150 Mscf 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2001 SANDY SUPPLY CO 703.00 0.00 365
2002 SANDY SUPPLY CO 709.00 0.00 365
2003 SANDY SUPPLY CO 1040.00 0.00 365
2004 SANDY SUPPLY CO 0.00 0.00 0
2005 SANDY SUPPLY CO 0.00 0.00 0
2006 SANDY SUPPLY CO 0.00 0.00 0
2007 SANDY SUPPLY CO 0.00 0.00 0
2008 SANDY SUPPLY CO 0.00 0.00 0
2009 SANDY SUPPLY CO 0.00 0.00 0
2010 SANDY SUPPLY CO 0.00 0.00 0
2011 SANDY SUPPLY CO 0.00 0.00 365
2012 SANDY SUPPLY CO 0.00 0.00 271

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2001 SANDY SUPPLY CO Brine 0 365
2002 SANDY SUPPLY CO Brine 0 365
2003 SANDY SUPPLY CO Brine 0 365
2004 SANDY SUPPLY CO Brine 0 0
2005 SANDY SUPPLY CO Brine 0 0
2006 SANDY SUPPLY CO Brine 0 0
2007 SANDY SUPPLY CO Brine 0 0
2008 SANDY SUPPLY CO Brine 0 0
2009 SANDY SUPPLY CO Brine 0 0
2010 SANDY SUPPLY CO Brine 0 0
2011 SANDY SUPPLY CO Brine 0 365
2012 SANDY SUPPLY CO Brine 0 271

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1065731495 2012-3-13 0:00: PW No Violations 1.00
-1091375898 2012-2-21 0:00: PW No Violations 1.00
-1523527570 2011-9-13 0:00: PW No Violations 1.50
-1531177654 2012-3-5 0:00:0 PW No Violations 1.00
-1767782917 2013-7-31 0:00: FR No Violations 0.50
-1907463841 2011-9-22 0:00: PW No Violations 1.00
-1933195076 2011-9-13 0:00: PW No Violations 1.50
-2134611448 2012-1-18 0:00: PW No Violations 1.00
-384083928 2012-2-24 0:00: PW No Violations 1.50
-856725022 2011-9-13 0:00: PW No Violations 1.50
0094569310 2012-02-28 Production Wells No Violations I checked on the well status today and found that the well remains shut in and not in operation. There has been no work done on the well to place it into production. I contacted the service rig contractors that were on the list I had given to Rick Yenny, to find out if he had contacted them to contract a service rig. All of them said that Rick Yenny had not contacted them.
0154634769 2012-02-14 Production Wells No Violations My inspection found that this well is not in production and that no repairs have been made. I contacted Rick at Sandy Supply, who stated that he does not have to plug or produce this well. He will check sometime to see if it can be repaired and if not maybe he will plug it. I questioned him on: A) what service company he was using and he said he did not know, B) what was his time frame for working on the well and he said that the well was producing for a while and it just locked up, C) if he had the line repaired that he claimed was damaged by the OEPA and he said no, D) how he could have had the well in operation if the line has not been repaired to which he had no response. I advised him I would seek a Chief Order to continue enforcement.
0377690031 2011-09-13 Production Wells Violations Noted Had call from Ohio EPA about idle well and tanks in poor maintenance. Checked well and found that well was idle and had trees growing up thru the well head equipment. Checked production records and found that well has not produced in years. Well should be placed into production, or plugged.
0384083928 2012-02-24 Production Wells No Violations I checked on this well today and found that it remains idle. I called Rick Yenny and advised him I would request a Chiefs Order to have the well plugged if not placed into production. He said that there are no service rigs available, so I gave him a list of at least 5 local service rig contractors. Next, I contacted the same local service rig contractors and notified them that Rick Yenny was in need of a service rig to complete plugging operations.
0567958780 2011-10-04 Production Wells No Violations Had call from Rick of Sandy Supply about the wells operation. He said that he could not operate the well safely because the OEPA has damaged his flow line and or production line. They have drilled holes into the line or have come close enough to the line to make it unsafe to produce the well. When I asked if the EPA actually drilled into the lines Rick said he did not know for sure , but it was unsafe to operate. I contacted Kurt Kollar of OEPA about this issue. He said that OEPA had not been in the area of the well or the production lines and that they have not drilled into the production lines. I asked if the scope of operation for the clean up of wellsite and production tanks would be of concern and he said they have nothing to clean up in that area. He said he would not object to the well being placed into production and had no safety issues. I then called Rick and told him of my discussionn with OEPA. I advised him that the well must be plugged or produced and either decision must be completed in a timely matter.
0644008691 2012-09-28 Plug / Plug Back No Violations The top cement plug dropped 5. They will cut the casing off there and weld a plate on top of it. This well was plugged and abandoned this date.
0856725022 2011-09-13 Production Wells No Violations FOLLOW UP TO NOV # 377690031 Had call from Ohio EPA about idle well and tanks in poor maintenance. Checked well and found that well was idle and had trees growing up thru the well head equipment. Checked production records and found that well has not produced in years. Well should be placed into production, or plugged.
0995553274 2012-09-27 Plug / Plug Back No Violations Petroset spotted a 40 sack cement plug from 2012 to 1862 thru tubing. The tubing was pulled out of the hole. The casing was ripped at 1571 and pulled and pulled out of the hole. The 1-1/2 tubing was then run back in the hole to 635 and the well was plugged out. See the plugging report for details.
1065731495 2012-03-13 Production Wells No Violations I checked this well to see if it was in operation and found that it was not.
1091375898 2012-02-21 Production Wells No Violations My inspection found this well was not in operation. I called Rick and left him a message to contact me about the repairs.
1523527570 2011-09-13 Production Wells No Violations FOLLOW UP TO NOV # -1933195076 FOLLOW UP TO NOV # 377690031 Had call from Ohio EPA about idle well and tanks in poor maintenance. Checked well and found that well was idle and had trees growing up thru the well head equipment. Checked production records and found that well has not pro
1531177654 2012-03-05 Production Wells No Violations My inspection found that the well remains idle and not in production. The seperator has no pressure on it. The pumping unit has not operated since my last inspection. There has been no phone contact from the well owner to the service rig companies.
1531867814 2013-07-23 Final Restoration No Violations There was no indication of the well, tank battery, or lease road. The location is now part of the parking area for the Wayne county fair. Final restoration passes.
154634769 2012-2-14 0:00: PW No Violations 1.00
1767782917 2013-07-31 Final Restoration No Violations Final restoration IS NOT APPROVED as the tank battery is still in place for the plugged well. With the plugging of the well, the NOV to plug and abandon is resolved.
1791629292 2012-09-26 Plug / Plug Back No Violations The tubing was hung in the hole. We were able to establish circulation to surface so we spotted a 30 sack bottom cement plug thru this tubing. We shot the tubing off at 2301. We pulled tubing up to 2012 and perforated with 2 shots. We pulled tubing to 1862 and perforated with 2 shots. We ran the tubing back to 2012 and shut the well in for the night.
1907463841 2011-09-22 Production Wells No Violations No work done on well or tanks. Well remains idle and is not in operation.
1933195076 2011-09-13 Production Wells No Violations FOLLOW UP TO NOV # 377690031 Had call from Ohio EPA about idle well and tanks in poor maintenance. Checked well and found that well was idle and had trees growing up thru the well head equipment. Checked production records and found that well has not pro
2134611448 2012-01-18 Production Wells No Violations I checked on status of this well today and found that there has been no work done to place well into production. This well remains shut in.
377690031 2011-9-13 0:00: PW No Violations 1.50
567958780 2011-10-4 0:00: PW No Violations 3.00
644008691 2012-9-28 0:00: PB No Violations
94569310 2012-2-28 0:00: PW No Violations 1.50
995553274 2012-9-27 0:00: PB No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0377690031 US-OH-123990 2011-09-16 Failure to legibly identify well
0377690031 US-OH-123991 2011-09-16 Nonproduction; well shall be plugged or placed in temporary inactive status

For data sources see[9]