If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-031-27190 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.38,"lon":-81.88,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Coshocton | |
Municipality: Mill Creek Township | |
Operator Name: ANADARKO E & P ONSHORE LLC | |
Well Pad ID: US-OH-000480 | |
Farm/Lease Name: COSH MILL CREEK | |
License Status: Plugged Back | |
License Date: 2012-05-22 | |
Spud Date: 2012-05-31 | |
Spud Drilling Contractor: KEY ENERGY | |
Final Drill Date: 2012-06-06 | |
Well Total Depth: 10216.00 ft | |
Configuration: Vertical | |
Latitude: 40.380000 | |
Longitude: -81.880000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2012-05-22 | Proposed Formations:TRENTON/BLACK RIVER, Issued Date:5/22/2012, Expired Date:5/22/2014 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT |
Reached Total Depth | 2012-06-06 | DeepestFMTN agrees with DGS-reference PG-2 |
Correction to Well | 2012-06-08 | CORRECTION TO PROPOSED TOTAL DEPTH, PROPOSED GEOLOGICAL FORMATION, CASING PROGRAM AND PERMIT CONDITIONS. |
Plugged Back | 2012-07-24 | DeepestFMTN agrees with DGS-reference PG-2 |
Completion Report Received | 2013-03-05 | DeepestFMTN agrees with DGS-reference PG-2 |
Construction Permit Expires | 2014-05-22 | DeepestFMTN agrees with DGS-reference PG-2 |
Record Last Modified | 2017-02-27 | DeepestFMTN agrees with DGS-reference PG-2 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2013-03-06 | 7176 | 6956 | 40 |
2013-03-06 | 7904 | 7694 | 40 |
2013-03-06 | 9639 | 9416 | 40 |
2013-03-06 | 9382 | 9178 | 40 |
2013-03-06 | 10131 | 9908 | 40 |
2013-03-06 | 9885 | 9662 | 40 |
2013-03-06 | 9144 | 8930 | 40 |
2013-03-06 | 8407 | 8186 | 40 |
2013-03-06 | 8157 | 7940 | 40 |
2013-03-06 | 8897 | 8682 | 40 |
2013-03-06 | 8650 | 8435 | 40 |
2013-03-06 | 6930 | 6710 | 40 |
10131 | 9908 | 40 | |
9885 | 9662 | 40 | |
9639 | 9416 | 40 | |
9382 | 9178 | 40 | |
9144 | 8930 | 40 | |
8897 | 8682 | 40 | |
8650 | 8435 | 40 | |
8407 | 8186 | 40 | |
8157 | 7940 | 40 | |
7904 | 7694 | 40 | |
7669 | 7448 | 40 | |
7425 | 7202 | 40 | |
7176 | 6956 | 40 | |
6930 | 6710 | 40 | |
6686 | 6464 | 40 | |
6437 | 6218 | 40 | |
6192 | 5972 | 40 | |
5948 | 5726 | 40 | |
5703 | 5480 | 40 | |
5703 | 5480 | 40 | |
2013-03-06 | 7669 | 7448 | 40 |
2013-03-06 | 7425 | 7202 | 40 |
2013-03-06 | 6686 | 6464 | 40 |
2013-03-06 | 5948 | 5726 | 40 |
2013-03-06 | 5703 | 5480 | 40 |
2013-03-06 | 6437 | 6218 | 40 |
2013-03-06 | 6192 | 5972 | 40 |
For data sources see[3]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 10/23/2012 | 10/23/2012 | 5220.00 | 10,816,650.0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | WBE-6 | Trican Well Service | Gel Breaker | No hazardous ingredients | 100.00 | 0.00 | ||
BioClear 5000 | Trican Well Service | Biocide | Polyethylene glycol | 25322-68-3 | 70.00 | 0.01 | ||
2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 10.00 | 0.00275000 | |||||
FEAC-20 | Trican Well Service | Iron Control | Citric acid | 77-92-9 | 30.00 | 0.00095000 | ||
Acetic acid | 64-19-7 | 50.00 | 0.00159000 | |||||
WG-111D | Trican Well Service | Water Gellant | Guar gum | 9000-30-0 | 100.00 | 0.00 | ||
FR-8 | Trican Well Service | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 28.00 | 0.00 | ||
Ammonium chloride | 12125-02-9 | 1.50 | 0.00 | |||||
Biobrom C-100G | Trican Well Service | Biocide | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 98.00 | 0.00 | ||
WBO-2 | Trican Well Service | Gel Breaker | Sodium persulfate | 7775-27-1 | 100.00 | 0.00 | ||
Acid, Hydrochloric (3.5) | Trican Well Service | General Acidizing | Hydrochloric acid | 7647-01-0 | 15.00 | 0.00 | ||
Water | 7732-18-5 | 85.00 | 0.00 | |||||
TXP-8 | Trican Well Service | Friction Reducer | Cationic water-soluble polymer emulsion | 100.00 | 0.06 | |||
TXP-11 | Trican Well Service | Clay Stabilizer | Inorganic chemical | 20.00 | 0.00 | |||
Chloride | 16887-00-6 | 30.00 | 0.00 | |||||
Poly electrolyte | 40.00 | 0.00 | ||||||
Water | 7732-18-5 | 60.00 | 0.00 | |||||
TXP-10 | Trican Well Service | Scale Inhibitor | 1,2-Propylene glycol | 57-55-6 | 10.00 | 0.00263000 | ||
Acrylate phosphonate copolymer | 40.00 | 0.01 | ||||||
Water | 7732-18-5 | 70.00 | 0.01 | |||||
Neutralized organic acid | 20.00 | 0.00525000 | ||||||
Spectrachem tracer | ProTechnics | Diagnostics | ||||||
WXB-10 | Trican Well Service | Fracturing Crosslinker | Ulexite | 1319-33-1 | 60.00 | 0.00 | ||
Distillates, petroleum, hydrotreated light | 64742-47-8 | 60.00 | 0.00 | |||||
Acid, Hydrochloric (7.5) | Trican Well Service | General Acidizing | Water | 7732-18-5 | 92.50 | 0.32 | ||
Hydrochloric acid | 7647-01-0 | 7.50 | 0.02 | |||||
Water | Anadarko | Carrier/Base Fluid | Water | 7732-18-5 | 100.00 | 90.84 | ||
FR-14 | Trican Well Service | Friction Reducer | Inorganic salt | 30.00 | 0.00 | |||
Acetic acid | 64-19-7 | 5.00 | 0.00 | |||||
DF-1 | Trican Well Service | Defoaming Agent | Non-hazardous materials only in the product | 100.00 | 0.00 | |||
WG-111L | Trican Well Service | Viscosifier/Gelant | Distillates, petroleum, hydrotreated light | 64742-47-8 | 60.00 | 0.00 | ||
Polysaccharide blend | 60.00 | 0.00 | ||||||
BXL-A | Trican Well Service | Gel Breaker | Proprietary | 70.00 | 0.00 | |||
Sand (Proppant) | Proppant | Methenamine | 100-97-0 | 1.00 | 0.08 | |||
Quartz | 14808-60-7 | 70.00 | 5.89 | |||||
Spectrachem tracer | Diagnostics | Sodium Salt | 10.00 | 0.00007000 | ||||
Water | 7732-18-5 | 91.00 | 0.00063000 | |||||
CS-1 | Trican Well Service | Clay Stabilizer | Inorganic salts | 30.00 | 0.07 | |||
1,2-Propylene glycol | 57-55-6 | 20.00 | 0.05 | |||||
Blend | 25.00 | 0.06 | ||||||
Surfactant | 5.00 | 0.01 | ||||||
GBO-1 | Trican Well Service | Gel Breaker | Sodium perborate tetrahydrate | 10486-00-7 | 100.00 | 0.00 | ||
Sand (Proppant) | Trican Well Service | Proppant | ||||||
Acid, Hydrochloric (7.5) | General Acidizing | |||||||
Acid, Hydrochloric (3.5) | General Acidizing | |||||||
AI-7NR | Trican Well Service | Corrosion Inhibitor | Propargyl alcohol | 107-19-7 | 1.00 | 0.00001000 |
For data sources see[4]
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2012 | ANADARKO E & P ONSHORE LLC | Brine | 22159 | 66 |
2013 | ANADARKO E & P ONSHORE LLC | Brine | 1794 | 0 |
2014 | NGO DEVELOPMENT CORP. | Brine | 1267 | 92 |
2015 | NGO DEVELOPMENT CORP. | Brine | 5944 | 365 |
2016 | NGO DEVELOPMENT CORP. | Brine | 1764 | 366 |
2017 | NGO DEVELOPMENT CORP. | Brine | 1142 | 365 |
2018 | M & R INVESTMENTS OHIO LLC | Brine | 663 | 198 |
2019 | M & R INVESTMENTS OHIO LLC | Brine | 133 | 90 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1184276866 | 2012-10-18 0:00 | CT | No Violations | 4.00 |
-134153103 | 2020-10-13 0:00 | PW | No Violations | 0.50 |
-1424696376 | 2012-5-31 0:00: | DD | No Violations | 2.00 |
-1495057527 | 2012-11-13 0:00 | CT | No Violations | |
-1576837445 | 2012-8-3 0:00:0 | DD | No Violations | 3.00 |
-2074061527 | 2012-10-18 0:00 | CT | No Violations | |
-2118515733 | 2012-7-11 0:00: | DD | No Violations | 5.00 |
-524632354 | 2018-2-9 0:00:0 | PW | No Violations | 1.50 |
-726923125 | 2020-4-22 0:00: | PW | No Violations | 0.50 |
-749816224 | 2016-8-8 0:00:0 | PW | No Violations | 0.50 |
0391420600 | 2012-06-06 | Drill / Deepen / Reopen | No Violations | 24casing was set to depth of 136.Wait on large drill rig. |
0524611641 | 2013-11-12 | Preliminary Restoration | No Violations | On the day of my inspection I found that nothing has been done to put this well in production and nothing has been done to reclaim the site. The well head was shut in and there was no production equipment. |
0524632354 | 2018-02-09 | Production Wells | No Violations | On the day of my inspection I found that the tubing and rods were back in the well, the wellhead was back together and the bridle was connected. The flow lines were all connected and the valves were open. I could hear gas coursing through the lines. There was heavy snow cover on the ground, but I found no signs of leaking in the snow around the wellhead, tanks or separator. |
0579691764 | 2015-05-29 | Preliminary Restoration | No Violations | On the day of my inspection I found that the preliminary restoration was complete on this location. The berms of the stone well pad were either fortified with large rocks or growing with vegetation. I found no signs of erosion around the pad or along the lease road. There was no drilling equipment or debris. Earthen pits were not used to drill this well. |
0749816224 | 2016-08-08 | Production Wells | No Violations | On the day of my inspection I found that the well was being produced with a natural gas powered pumping unit. The unit was in operation at the time of inspection. The pumping unit was fenced with chain link. The tank battery consisted of two dikes, one containing three 210 barrel steel tanks and the other containing one horizontal separator. Correct, legible identification was posted and I found no leaks or spills. |
0977236267 | 2019-03-25 | Production Wells | No Violations | On the day of my inspection I found that the gate at the site entrance was locked and an identification sign was posted. The access road and the surrounding landscape were in good condition. The natural gas powered pumping unit was in operation at the time of my inspection. I found no leaks around the wellhead or unit. There were no leaks or spills around the three 210 barrel steel tanks, or the horizontal separator. The load valve was equipped with a bull plug. Correct, legible identification was posted on one of the tanks. There were no signs of erosion or slippage around the well pads. |
1141347113 | 2013-04-26 | Production Wells | No Violations | On the day of my inspection I found that the well head was shut in with multiple valves and equipped with remote monitoring devices. There were no lines connected and there were no storage tanks present. All drilling, completion and testing equipment has been removed from the location. The location was fenced and locked, there were no leaks or spills and proper identification was posted at the well pad. |
1184276866 | 2012-10-18 | Completion Testing | No Violations | Well is being fraced by Trican services. They are currently on stage 9. Met consultant named Jerry Trout. The Horizontal loggers will pump the casing gun down to the next stage. |
1342714442 | 2012-07-19 | Drill / Deepen / Reopen | No Violations | On day of inspection Key rig 886 is at a depth of 6300 around the trempleau formation. 115 units of gas is the highest gas count from the mud loggers to date. |
1343151574 | 2012-07-23 | Plug / Plug Back | No Violations | Key rig |
1357757085 | 2013-01-09 | Completion Testing | No Violations | On the day of my inspection I found that Express Well Services was on location monitoring the flow back. There was no report of natural gas shows and the flares were not ignited. All of the flow back equipment was on containment liners and dikes. There were no leaks or spills. |
1404321221 | 2014-07-02 | Production Wells | Violations Noted | On the day of my inspection I found that the well was not in production. The wellhead was shut in and there was no production equipment on or near the location. The annual production reports show 0 MCF of gas and 0 barrels of oil for 2013. Plug the well within 180 days of the issuance of this compliance notice. |
1424696376 | 2012-05-31 | Drill / Deepen / Reopen | No Violations | Zigeenfuss is drilling top hole. They finished mouse hole. Will drill 24into good rock. |
1495057527 | 2012-11-13 | Completion Testing | No Violations | On the day of my inspection I found that Express Oilfield Services was setting up to flow the well back. The frac plugs were already drilled out, and there were no reports of any oil or gas shows. There were no leaks or spills, all equipment was on containment liners and dikes. No violations at this time. |
1510067818 | 2017-11-07 | Production Wells | No Violations | On the day of my inspection I found that the bridle was disconnected and the rods were out of the well. I called NGO pumper Chase Dyer to ask what they were doing. He said that the pump was parted and they were waiting for a service rig to pull the tubing. The production equipment consisted of three 210 barrel steel tanks in an earthen dike and one horizontal separator in a smaller dike. There were no leaks around the wellhead or production equipment. Correct, legible identification was posted on one of the tanks. |
1576837445 | 2012-08-03 | Drill / Deepen / Reopen | No Violations | Production string was completed by Key energy rig 886 and Halliburton. Rig 886 ran 20lb/ft of 5.5casing to depth of 10,188. The total depth was at 10,216in a 7.875open hole. Good circulation was established. Top of cement should be at 3224. |
2014340348 | 2015-01-23 | Production Wells | No Violations | I received a call from Scott Kees of NGO to inform me that they were assuming ownership of this well, and they were trying to produce it. On the day of my inspection I found that the well had been equipped with a pumping unit. The unit was pumping at the time of my inspection. The valve was open and the gauge showed 250 psi. The well was pumping into a 300 barrel frac tank. There was also a temporary gas line running to a separator. This well has been made capable of production. This violation is resolved. |
2074061527 | 2012-10-18 | Completion Testing | No Violations | On the day of my inspection I found that Trican was on the 9th stage of well completion. All equipment was on containment liner and there were no leaks or spills. There were no significant pressure changes during inspection. No violations at this time. |
2118515733 | 2012-07-11 | Drill / Deepen / Reopen | No Violations | On day of inspection Key rig 886 ran 8 .625casing and Universal cemented string in place. Good circulation. |
391420600 | 2012-6-6 0:00:0 | DD | No Violations | 1.00 |
461415851 | 2019-10-16 0:00 | PW | No Violations | 0.50 |
524611641 | 2013-11-12 0:00 | PL | No Violations | |
579691764 | 2015-5-29 0:00: | PL | No Violations | |
977236267 | 2019-3-25 0:00: | PW | No Violations | 0.60 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1404321221 | US-OH-111838 | 2015-01-26 | Well shall be plugged |
For data sources see[7]