{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.55,"lon":-82.33,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Hocking | |
Municipality: Green Township | |
Operator Name: HOCKING HILLS ENERGY AND WELL | |
Well Pad ID: | |
Farm/Lease Name: LINTON LESLIE & GRAHAM CHARLES | |
License Status: Producing | |
License Date: 1994-03-08 | |
Spud Date: 1981-04-05 | |
Spud Drilling Contractor: | |
Final Drill Date: 1981-04-20 | |
Well Total Depth: 3158.00 ft | |
Configuration: Vertical | |
Latitude: 39.550000 | |
Longitude: -82.330000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1980-12-30 | 566 GRIM PAUL A GeoDate 12/30/80 |
Oil and Gas | 1980-12-30 | Issued Date 12/30/80 Expired Date Acres 0030000 Tool Type RTF Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000 |
Original Spud | 1981-04-05 | |
Completed | 1981-04-20 | |
Reached Total Depth | 1981-04-20 | |
Completion Report Received | 1981-05-14 | |
Annular Disposal Well | 1994-03-08 | |
Revocation | 1999-04-30 | |
Change of Owner | 2001-10-29 | Operator changed from 566, GRIM PAUL A to 5755, CHIEFTAIN ENERGY CORP. |
Record Last Modified | 2018-04-05 | |
Last Compliance Report | 2018-04-06 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 0 | 3 | |
0 | 3 | ||
0 | 3 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 15 | 3500 Bbl | 20000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | MADCO ENERGY CORP | 1021.00 | 1144.00 | 0 |
1985 | MADCO ENERGY CORP | 0.00 | 1560.00 | 365 |
1986 | GRIM PAUL A | 0.00 | 1182.00 | 365 |
1987 | GRIM PAUL A | 0.00 | 476.00 | 365 |
1988 | GRIM PAUL A | 0.00 | 543.00 | 365 |
1989 | GRIM PAUL A | 0.00 | 50.00 | 365 |
1990 | GRIM PAUL A | 0.00 | 67.00 | 365 |
1991 | GRIM PAUL A | 0.00 | 85.00 | 365 |
1992 | GRIM PAUL A | 0.00 | 0.00 | 365 |
1993 | GRIM PAUL A | 0.00 | 0.00 | 365 |
1994 | GRIM PAUL A | 0.00 | 0.00 | 365 |
1995 | GRIM PAUL A | 0.00 | 24.00 | 365 |
2002 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 0 |
2003 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 10 |
2004 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 90 |
2005 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 365 |
2006 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 365 |
2007 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 30 |
2008 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 0 |
2009 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 0 |
2010 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 180 |
2011 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 0 |
2012 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 360 |
2014 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 0 |
2016 | HOCKING HILLS ENERGY AND WELL | 0.00 | 45.00 | 365 |
2017 | HOCKING HILLS ENERGY AND WELL | 0.00 | 0.00 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1281046446 | 2004-8-25 0:00: | AD | No Violations | |
-1376017019 | 2010-1-6 0:00:0 | AD | No Violations | |
-142776628 | 2017-2-6 0:00:0 | PW | No Violations | 1.00 |
-1522222142 | 2009-5-28 0:00: | PW | No Violations | |
-166482331 | 2010-2-3 0:00:0 | PW | No Violations | |
-198708677 | 2013-6-10 0:00: | PW | No Violations | 1.00 |
-430911409 | 2010-7-19 0:00: | AD | No Violations | |
-572214142 | 2009-12-10 0:00 | PW | No Violations | |
-627834204 | 2010-10-28 0:00 | AD | No Violations | 1.50 |
-637060272 | 2018-2-12 0:00: | PW | No Violations | 2.00 |
-685102835 | 2003-11-5 0:00: | AD | No Violations | |
-768670262 | 2004-7-20 0:00: | AD | No Violations | |
-848655574 | 2018-3-13 0:00: | TD | No Violations | 0.40 |
-991253484 | 2010-5-3 0:00:0 | PW | No Violations | |
01269i1027 | 2002-05-13 | Annular Disposal | No Violations | Folow-up on NOV, In-Compliance. |
0142776628 | 2017-02-06 | Production Wells | Violations Noted | I received a request from Realtor Marlin Schneider. Mrs. Schneider has the property listed for sale. My inspection revealed a pumping unit, 1-100 barrel tank and 1- |
0166482331 | 2010-02-03 | Production Wells | No Violations | A follow-up inspection revealed non-compliance. The old 100 bbl tank has now been removed from the location. The well status remains unchanged. The valves remain closed, and no motor for pumping unit. |
0198708677 | 2013-06-10 | Production Wells | No Violations | Compliance notice follow up, the tank dike has been cleaned of crude oil and rebuilt. This satisfies the compliance notice dated 09/17/2012. |
0354155891 | 2017-08-03 | Production Wells | No Violations | Compliance notice follow-up. The well has been worked on. There is a new knock out tank. I spoke with well owner Doug Kitchen and stated the well needs a new electric motor. He stated the motor will be installed by 8.8.17. |
0430911409 | 2010-07-19 | Annular Disposal | No Violations | A follow-up inspection revealed non-compliance. The well status remains unchanged, as valves were observed closed, no motor or house gas received. |
0572214142 | 2009-12-10 | Production Wells | No Violations | A follow-up inspection conducted with Mr. Robert Stonerock, South Region Oil & Gas Supervisor revealed non-compliance. The well still remains idle. The well owner states they have met with AEP regarding electric being routed to this well. Note: light snow cover observed around well site at time of inspection. The landowner has recently voiced concerns in regards to lease road condition. The lease road contained no erosion at this time. Mr. Doug Kitchen had previously agreed to a 12/30/2009 deadline for idle well per Compliance Schedule. |
0606473681 | 2017-08-09 | Production Wells | No Violations | Compliance notice follow-up. The well is capable of production, I witnessed a video the well owner provide me showing the new knock out tank and the well in operation. This satisfies the compliance notice. |
0627834204 | 2010-10-28 | Annular Disposal | No Violations | Mr. Doug Kitchen and Mr. Ron McBride notified the Division today to state said well has been placed back into production. A follow-up inspection revealed that the well was pumping. Leak would later be observed, as polish rod liner required tightening. Mr. Kitchen stated that oil was observed on backside of annulus between 4.5 and 8 casing therefore, connection made to allow flow back into the 4.5. Gas observed from opposite side well on casing side. Mr. Kitchen was advised during this inspection that statements of production have not been submitted for years 2007-2009 on all wells under Chieftain Energy. Mr. Kitchen stated that he will have submitted production by noon on Monday. |
0637060272 | 2018-02-12 | Production Wells | No Violations | I received a request from Mr. Jeremy Brady who works for HER Realtors. He has the property for sale and asked me to inspect the well. This well was recently worked on by well owner Hocking Hills Energy. The well reported 45 barrels of oil in 2016. The well consists of a pumping unit and 1-210 barrel tanks. I called Mr. Brady today and informed him of my findings. |
0685102835 | 2003-11-05 | Annular Disposal | Violations Noted | An inspection of the well revealed production tanks leaking around seam on bottom of tanks, dike around production tanks does not meet SPCC requirements, not large enough. 1/12/04 to date company has not complied with NOV and corrected violations, turned over to management. |
0768670262 | 2004-07-20 | Annular Disposal | Violations Noted | An inspection of the well revealed well is idle, according to records submitted by company well has not produced for over 2 years. All the equipment there on the well, valves open on well head, no gas on well. |
0848655574 | 2018-03-13 | Temporary Abandoned Annular Disposal | No Violations | I received a request from central office to determine if this well was being used for annular disposal. The well is not being used for annular disposal. |
0953793918 | 2012-10-17 | Production Wells | No Violations | Contaminated soil has been removed from the dike. One side of the dike has been rebuilt. Tank battery is in compliance. |
0954078931 | 2004-02-25 | Annular Disposal | No Violations | Follow-up on NOV, In-Compliance. |
0991253484 | 2010-05-03 | Production Wells | No Violations | A follow-up inspection revealed non-compliance. The well status remains the same, as there is no installed motor and valves remain closed. A meter has been installed at the electric pole location. Vegetative growth observed outside the dike. |
1071844343 | 2003-12-18 | Annular Disposal | No Violations | Follow-up on NOV, Non-Compliance, company has not repaired or replaced leaking tanks. Dike wall has not been rebuilt or repaired. 1/12/04 to date company has not complied with NOV and corrected violations, turned over to management. |
1099919309 | 2004-11-04 | Annular Disposal | No Violations | Follow-up on NOV, In-Compliance |
1220624476 | 2018-02-13 | Temporary Abandoned Annular Disposal | No Violations | I received a request from central office to determine if this well was being used for annular disposal. The well is not being used for annular disposal. |
1244642943 | 2009-05-28 | Production Wells | Violations Noted | A complaint was received alleging non-production. Contacted Mr. Doug Kitchen at 12:57 pm, 740-215-6883. He was informed that a complaint was received on this well today. He stated that the well made a lot of water and would like to test AD. Further stating that if it were to fail the required test, he would plug and abandon. An inspection revealed that the well is idle. The well consisted of pumping unit with engine, belts, cylinder head. The bridle was attached and weights installed on the beam. The AD remains disconnected. A 2 black plastic line was found connected from the pumping tee to a 100 bbl tank with no knockout. Unable to tell if the valve from pumping tee was open. The valve on casing at the well head was found closed (on left side). On right hand side, the valve was found open with 1 black plastic routed to the engine. Two propane tanks were also observed near the engine location. At the tank location bare areas were observed inside and outside the earthen dike. Deer tracks and signs of sodicity were observed. Measurements were approximately 25 x 10 outside/inside and behind tank; 20 x 10 and 25 x 10 along the sides. High Range Quantabs revealed 4.2 units inside the dike, which equals 1079 ppm (mg/L) Cl-. 5.0 units, 1516 ppm (mg/L) Cl- were observed outside the dike. The dike will need to be repaired. Note: A second 100bbl tank located outside the dike and not connected. The production records, in RBDMS, for this well were reviewed and showed that 1995 was the last year of production. It was also noted that the well had been transferred from Paul Grim to Chieftain Energy in 2001. Moreover, Chieftain Energy is in violation of ORC 1509.11 for failing to submit a statement of production of oil, gas, and brine for 2007 and 2008. A complaint was received by DMRM alleging non-production. An inspection revealed that the well is idle. Plug or produce this well. Bare areas were observed inside and outside the earthen dike. High Range Q |
1269i1027 | 2002-5-13 0:00: | AD | No Violations | |
1269i87957 | 2002-03-19 | Annular Disposal | No Violations | An inspection of the well revealed No ID at the well or tank battery, need full ID at the well or tank battery. Note need to work on dike walls at tank battery. |
1269i87957143 | 2002-3-19 0:00: | AD | No Violations | |
1281046446 | 2004-08-25 | Annular Disposal | No Violations | Follow-up on NOV, Non-Compliance, no action to comply. |
1347968647 | 2012-09-17 | Production Wells | Violations Noted | Well head in compliance. Tank battery showed signs of leakage. There was fluid on the inside of the dike that covered the bottom and caused a vegetation kill. There was also a vegetation kill on the outside of the dike. Both of these areas need remediated, and vegetation re-established. The cause of the fluid leak also needs to be repaired. |
1376017019 | 2010-01-06 | Annular Disposal | No Violations | A follow-up inspection to NOV and Compliance Schedule revealed non-compliance. During the inspection, it was noted that an electric pole with no meter has been placed at entrance to lease road. An electric line will need to be installed and routed to the well. The pumping unit does not contain a motor or engine. Valves on casing remain closed. Plastic line connected to 100 bbl tank derives from connection to pumping tee side of well. Note: winter conds to include snow cover at time of inspection. |
1522222142 | 2009-05-28 | Production Wells | No Violations | FOLLOW UP TO NOV # 1244642943 A complaint was received alleging non-production. Contacted Mr. Doug Kitchen at 12:57 pm, 740-215-6883. He was informed that a complaint was received on this well today. He stated that the well made a lot of water and would like to test AD. Further s |
1523940372 | 2009-07-20 | Production Wells | No Violations | A follow-up inspection to Notice of Violation and Compliance Agreement Schedule revealed that lime & seed has been applied to bare areas inside and outside dike. Mulch was not applied. Prior to this inspection, a 7/14/2009 meeting had been conducted with both Mr. Doug Kitchen, well owner, and Mr. Ron McBride, Chieftain Energy Contractor. During the meeting a Compliance Schedule was agreed upon by both parties. The deadline for remediation was 7/24/2009. The deadline for non-production has been set for 12/30/2009. |
1696310584 | 2009-05-28 | Production Wells | Violations Noted | FOLLOW UP TO NOV # -1522222142 FOLLOW UP TO NOV # 1244642943 A complaint was received alleging non-production. Contacted Mr. Doug Kitchen at 12:57 pm, 740-215-6883. He was informed that a complaint was received on this well today. He stated that the well made a lot of water and would like to test AD. Further s |
2037220185 | 2012-09-17 | Production Wells | No Violations | FOLLOW UP TO NOV # 1347968647 Well head in compliance. Tank battery showed signs of leakage. There was fluid on the inside of the dike that covered the bottom and caused a vegetation kill. There was also a vegetation kill on the outside of the dike. Both of these areas need remediated, and vegetation re-established. The cause of the fluid leak also needs to be repaired. |
354155891 | 2017-8-3 0:00:0 | PW | No Violations | 0.50 |
606473681 | 2017-8-9 0:00:0 | PW | No Violations | |
953793918 | 2012-10-17 0:00 | PW | No Violations | 2.00 |
954078931 | 2004-2-25 0:00: | AD | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0142776628 | US-OH-112481 | 2017-08-11 | NONE | Well shall be plugged |
0685102835 | US-OH-127745 | 2003-11-10 | Well operation causing pollution and contamination | |
0685102835 | US-OH-127746 | 2003-11-10 | Equipment pressure rated below operating pressure | |
0685102835 | US-OH-127747 | 2003-11-10 | No SPCC dike/or failure to keep dike free of water or oil | |
0685102835 | US-OH-127748 | 2003-11-10 | Unlawful method of storage or disposal of brine or other wastes | |
0768670262 | US-OH-128740 | 2004-07-20 | Well shall be plugged | |
1244642943 | US-OH-106528 | 2009-06-17 | Well operation causing pollution and contamination | |
1244642943 | US-OH-106529 | 2009-06-17 | Unlawful method of storage or disposal of brine or other wastes | |
1244642943 | US-OH-106530 | 2009-06-17 | Failure to keep SPCC dike/pit free of brine and other wastes | |
1244642943 | US-OH-106531 | 2009-06-10 | No SPCC dike/or failure to keep dike free of water or oil | |
1244642943 | US-OH-106532 | 2009-06-10 | Well shall be plugged | |
1347968647 | US-OH-110073 | 2012-09-18 | Well operation causing pollution and contamination | |
1696310584 | US-OH-116823 | 2017-09-27 | 9-1-07 | Well operation causing pollution and contamination |
For data sources see[9]