{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.5,"lon":-81.51,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: BASS ENERGY CO INC | |
Well Pad ID: | |
Farm/Lease Name: CHURCH OF THE GOOD SHEPHERD UNIT | |
License Status: Producing | |
License Date: 2004-12-02 | |
Spud Date: 2004-12-07 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2004-12-15 | |
Well Total Depth: 3669.00 ft | |
Configuration: Directional | |
Latitude: 41.500000 | |
Longitude: -81.510000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2004-12-02 | Proposed Formations:CLINTON, Issued Date:12/2/2004, Expired Date:12/2/2005 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL |
Original Spud | 2004-12-07 | DRILLING REPORT REQUESTED & SENT BY BASS ENERGY, 12-27- |
Completed | 2004-12-15 | DRILLING REPORT REQUESTED & SENT BY BASS ENERGY, 12-27- |
Reached Total Depth | 2004-12-15 | DRILLING REPORT REQUESTED & SENT BY BASS ENERGY, 12-27- |
Completion Report Received | 2005-02-17 | DRILLING REPORT REQUESTED & SENT BY BASS ENERGY, 12-27- |
Correction to Well | 2005-03-25 | CORRECTION TO TARGET INFORMATION: FOOTAGE= 624'SL & 1154'EL OF LOT 73; X= 2,270,760; Y= 670,550. |
Construction Permit Expires | 2005-12-02 | DRILLING REPORT REQUESTED & SENT BY BASS ENERGY, 12-27- |
Record Last Modified | 2017-02-15 | DRILLING REPORT REQUESTED & SENT BY BASS ENERGY, 12-27- |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2005-04-07 | 3484 | 3536 | 35 |
3484 | 3536 | 35 | |
3484 | 3536 | 35 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 15 | 56078 Gal | 30000 | 500 GALLONS HCL ACID |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2005 | BASS ENERGY CO INC | 19592.00 | 89.00 | 365 |
2006 | BASS ENERGY CO INC | 36751.00 | 92.00 | 365 |
2007 | BASS ENERGY CO INC | 30329.00 | 67.00 | 365 |
2008 | BASS ENERGY CO INC | 27579.00 | 88.00 | 365 |
2009 | BASS ENERGY CO INC | 25716.00 | 41.00 | 365 |
2010 | BASS ENERGY CO INC | 23107.00 | 45.00 | 365 |
2011 | BASS ENERGY CO INC | 20757.00 | 0.00 | 0 |
2012 | BASS ENERGY CO INC | 21231.00 | 62.00 | 366 |
2013 | BASS ENERGY CO INC | 18171.00 | 0.00 | 365 |
2014 | BASS ENERGY CO INC | 12117.00 | 0.00 | 365 |
2015 | BASS ENERGY CO INC | 14232.00 | 65.00 | 365 |
2016 | BASS ENERGY CO INC | 15739.00 | 0.00 | 365 |
2017 | BASS ENERGY CO INC | 14781.00 | 0.00 | 365 |
2018 | BASS ENERGY CO INC | 13949.00 | 68.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2005 | BASS ENERGY CO INC | Brine | 295 | 365 |
2006 | BASS ENERGY CO INC | Brine | 145 | 365 |
2007 | BASS ENERGY CO INC | Brine | 77 | 365 |
2008 | BASS ENERGY CO INC | Brine | 3 | 365 |
2009 | BASS ENERGY CO INC | Brine | 91 | 365 |
2010 | BASS ENERGY CO INC | Brine | 105 | 365 |
2011 | BASS ENERGY CO INC | Brine | 45 | |
2012 | BASS ENERGY CO INC | Brine | 70 | 366 |
2013 | BASS ENERGY CO INC | Brine | 0 | 365 |
2014 | BASS ENERGY CO INC | Brine | 30 | 365 |
2015 | BASS ENERGY CO INC | Brine | 45 | 365 |
2016 | BASS ENERGY CO INC | Brine | 81 | 365 |
2017 | BASS ENERGY CO INC | Brine | 55 | 365 |
2018 | BASS ENERGY CO INC | Brine | 50 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1077151688 | 2004-12-8 0:00: | DD | No Violations | |
-347879715 | 2011-12-22 0:00 | UL | No Violations | 1.00 |
-606402332 | 2015-3-9 0:00:0 | UP | No Violations | 0.50 |
0347879715 | 2011-12-22 | UrbanPreliminary Restoration | No Violations | On 12/22/2011, DNR Inspector Richard Skidmore completed an urban preliminary restoration well inspection for DNR Inspector Ray Wallace. The lease road, tank battery, and well head locations are in compliance with 1501:9-9-05. Inspection passed. |
0495614225 | 2014-10-09 | UrbanProduction Wells | No Violations | I inspected this producing unit as part of routine inspection activity. The wellhead is comprised of a mechanical plunger lift system in a board-on-board enclosure. Valves and connections are free from signs of leakage and appear functional. Areas surrounding the well area well maintained and free from signs of impact. The well is being returned to production following a shut-in period caused by on-going work with Dominion/East Ohio Gas distribution lines. Signage is present. The tank battery in a separate chain-link enclosure. The fittings and connections within the tank battery are free from leaks. The secondary containment is intact and the interior is free of signs of leaks, spills, or other problems. The load-outs are bull-plugged. The gate is secure. |
0606402332 | 2015-03-09 | UrbanProduction Wells | No Violations | I inspected this well as part of routine inspection activity. Access to the well and battery are via the shared, asphalt-paved driveway which services the church and associated parking. The wellhead plunger lift and battery are in separate enclosures. At the time of my inspection, the enclosure gates are locked, load-outs are plugged, secure, and locked, and connections and fittings are secure and free from signs of leakage or other problems. The well and battery are located in an area which grades to the west, towards an unnamed stream. At the time of this inspection, the surrounding areas are snow-covered. I did not observe any signs of impact relating to the on-going production activity at the time of this inspection. |
0734714820 | 2004-12-16 | Drill / Deepen / Reopen | No Violations | moving rig to gates mills |
1077151688 | 2004-12-08 | Drill / Deepen / Reopen | No Violations | drilling (1200) picked up surface ticket which was set on 12/07/04 not witnessed because of IM training. |
1324565064 | 2011-12-22 | UrbanPreliminary Restoration | No Violations | Urban preliminary restoration inspection due. Inspection conducted and well is in compliance with 1501:9-9-05. Well passed. |
1372859657 | 2013-07-03 | UrbanPreliminary Restoration | No Violations | The producing unit consists of the following elements: a wellhead with mechanical plunger lift system and associated above-ground storage tank (AST) battery, which are both separately enclosed in and locked. The battery is comprised of 1 140-barrel and 1 50-barrel AST, mechanical separator, and Dominion metering run. Secondary containment is present and adequate. Loadouts are bull-headed and locked. Preliminary restoration passes. |
1383331018 | 2017-11-30 | UrbanProduction Wells | No Violations | I inspected this well as part of routine inspection activity. The well and battery are located on the front portion of a church property . At the time of this inspection, I found the following: a wellhead plunger-lift unit and associated battery in separate chain-link enclosures. The fittings and connections were secure and free from leakage or problems. Fittings and connections at the battery were secure. The load-lines were plugged and locked. ID signage was present and current. The secondary containment was intact with no signs of leakage, spills, or problems. The well was in active production. The chart recorder was active. Production reports and insurance were current. |
495614225 | 2014-10-9 0:00: | UP | No Violations | |
734714820 | 2004-12-16 0:00 | DD | No Violations |