Well ID: 34-035-21857 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.4,"lon":-81.64,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: AM-TEK OIL INC | |
Well Pad ID: | |
Farm/Lease Name: ROCKSIDE WOODS | |
License Status: Producing | |
License Date: 2005-10-04 | |
Spud Date: 2006-03-10 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2006-03-14 | |
Well Total Depth: 3146.00 ft | |
Configuration: Vertical | |
Latitude: 41.400000 | |
Longitude: -81.640000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2005-10-04 | Proposed Formations:CLINTON, Issued Date:10/4/2005, Expired Date:10/4/2006 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL |
Original Spud | 2006-03-10 | RBDMS Rec |
Completed | 2006-03-14 | RBDMS Rec |
Reached Total Depth | 2006-03-14 | RBDMS Rec |
Completion Report Received | 2006-05-01 | RBDMS Rec |
Construction Permit Expires | 2006-10-04 | RBDMS Rec |
Record Last Modified | 2017-02-15 | RBDMS Rec |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-07-13 | 2955 | 3022 | 41 |
2955 | 3022 | 41 | |
2955 | 3022 | 41 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 15 | 70000 Gal | 0 | 500 GALLONS HCL ACID |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2006 | DUCK CREEK ENERGY INC | 2659.00 | 194.00 | 153 |
2007 | DUCK CREEK ENERGY INC | 8552.00 | 366.00 | 365 |
2008 | DUCK CREEK ENERGY INC | 4620.00 | 200.00 | 365 |
2009 | DUCK CREEK ENERGY INC | 2759.00 | 174.00 | 365 |
2010 | DUCK CREEK ENERGY INC | 2839.00 | 51.00 | 365 |
2011 | DUCK CREEK ENERGY INC | 1866.00 | 95.00 | 365 |
2012 | DUCK CREEK ENERGY INC | 1699.00 | 98.00 | 366 |
2013 | DUCK CREEK ENERGY INC | 1087.00 | 44.00 | 365 |
2014 | DUCK CREEK ENERGY INC | 1015.00 | 69.00 | 365 |
2015 | DUCK CREEK ENERGY INC | 827.00 | 44.00 | 365 |
2016 | DUCK CREEK ENERGY INC | 778.00 | 88.00 | 365 |
2017 | DUCK CREEK ENERGY INC | 673.00 | 40.00 | 365 |
2018 | DUCK CREEK ENERGY INC | 538.00 | 43.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2006 | DUCK CREEK ENERGY INC | Brine | 540 | 153 |
2007 | DUCK CREEK ENERGY INC | Brine | 752 | 365 |
2008 | DUCK CREEK ENERGY INC | Brine | 552 | 365 |
2009 | DUCK CREEK ENERGY INC | Brine | 400 | 365 |
2010 | DUCK CREEK ENERGY INC | Brine | 230 | 365 |
2011 | DUCK CREEK ENERGY INC | Brine | 339 | 365 |
2012 | DUCK CREEK ENERGY INC | Brine | 192 | 366 |
2013 | DUCK CREEK ENERGY INC | Brine | 155 | 365 |
2014 | DUCK CREEK ENERGY INC | Brine | 103 | 365 |
2015 | DUCK CREEK ENERGY INC | Brine | 175 | 365 |
2016 | DUCK CREEK ENERGY INC | Brine | 198 | 365 |
2017 | DUCK CREEK ENERGY INC | Brine | 132 | 365 |
2018 | DUCK CREEK ENERGY INC | Brine | 117 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
1033873281 | 2019-10-28 0:00 | UP | No Violations | 0.50 |
1467023831 | 2014-01-08 | UrbanPreliminary Restoration | No Violations | The producing unit consists of a wellhead with mechanical plunger lift and aboveground storage tank battery. The battery is comprised of one 100-barrel production tank and one 100-barrel brine tank, mechanical separator, and associated piping runs. Both the wellhead and battery are enclosed in chain-link fence enclosures which are locked. Secondary containment, signage, and process safety equipment are good. |
1507299865 | 2017-10-06 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: The wellhead plunger lift system and associated tank battery located in an otherwise undeveloped parcel. The load lines were plugged and secure. The secondary containment was intact and dry with no signs of leaks or spills. Fittings and connections at the wellhead and battery were secure and free from leakage or problems. I walked the areas surrounding the wellhead and battery which are comprised of wild vegetated areas with piles of gravel and slag stored variously throughout, and found no signs of impact or degradation attributable to the production system. |
1534953048 | 2018-08-22 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: The well was in active production. The load lines were plugged and secure. The secondary containment was intact and dry with no signs of leaks or spills. Fittings and connections at the wellhead and battery were secure and free from leakage or problems. I walked the areas surrounding the wellhead and battery which are comprised of wild vegetated areas with piles of gravel and slag stored variously throughout, and found no signs of impact or degradation attributable to the production system. |
For data sources see[9]