34-035-21857

Well Details

Well ID: 34-035-21857
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: AM-TEK OIL INC
Well Pad ID:
Farm/Lease Name: ROCKSIDE WOODS
License Status: Producing
License Date: 2005-10-04
Spud Date: 2006-03-10
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2006-03-14
Well Total Depth: 3146.00 ft
Configuration: Vertical
Latitude: 41.400000
Longitude: -81.640000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-10-04 Proposed Formations:CLINTON, Issued Date:10/4/2005, Expired Date:10/4/2006 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2006-03-10 RBDMS Rec
Completed 2006-03-14 RBDMS Rec
Reached Total Depth 2006-03-14 RBDMS Rec
Completion Report Received 2006-05-01 RBDMS Rec
Construction Permit Expires 2006-10-04 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-07-13 2955 3022 41
2955 3022 41
2955 3022 41

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 70000 Gal 0 500 GALLONS HCL ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 DUCK CREEK ENERGY INC 2659.00 194.00 153
2007 DUCK CREEK ENERGY INC 8552.00 366.00 365
2008 DUCK CREEK ENERGY INC 4620.00 200.00 365
2009 DUCK CREEK ENERGY INC 2759.00 174.00 365
2010 DUCK CREEK ENERGY INC 2839.00 51.00 365
2011 DUCK CREEK ENERGY INC 1866.00 95.00 365
2012 DUCK CREEK ENERGY INC 1699.00 98.00 366
2013 DUCK CREEK ENERGY INC 1087.00 44.00 365
2014 DUCK CREEK ENERGY INC 1015.00 69.00 365
2015 DUCK CREEK ENERGY INC 827.00 44.00 365
2016 DUCK CREEK ENERGY INC 778.00 88.00 365
2017 DUCK CREEK ENERGY INC 673.00 40.00 365
2018 DUCK CREEK ENERGY INC 538.00 43.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 DUCK CREEK ENERGY INC Brine 540 153
2007 DUCK CREEK ENERGY INC Brine 752 365
2008 DUCK CREEK ENERGY INC Brine 552 365
2009 DUCK CREEK ENERGY INC Brine 400 365
2010 DUCK CREEK ENERGY INC Brine 230 365
2011 DUCK CREEK ENERGY INC Brine 339 365
2012 DUCK CREEK ENERGY INC Brine 192 366
2013 DUCK CREEK ENERGY INC Brine 155 365
2014 DUCK CREEK ENERGY INC Brine 103 365
2015 DUCK CREEK ENERGY INC Brine 175 365
2016 DUCK CREEK ENERGY INC Brine 198 365
2017 DUCK CREEK ENERGY INC Brine 132 365
2018 DUCK CREEK ENERGY INC Brine 117 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
1033873281 2019-10-28 0:00 UP No Violations 0.50
1467023831 2014-01-08 UrbanPreliminary Restoration No Violations The producing unit consists of a wellhead with mechanical plunger lift and aboveground storage tank battery. The battery is comprised of one 100-barrel production tank and one 100-barrel brine tank, mechanical separator, and associated piping runs. Both the wellhead and battery are enclosed in chain-link fence enclosures which are locked. Secondary containment, signage, and process safety equipment are good.
1507299865 2017-10-06 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: The wellhead plunger lift system and associated tank battery located in an otherwise undeveloped parcel. The load lines were plugged and secure. The secondary containment was intact and dry with no signs of leaks or spills. Fittings and connections at the wellhead and battery were secure and free from leakage or problems. I walked the areas surrounding the wellhead and battery which are comprised of wild vegetated areas with piles of gravel and slag stored variously throughout, and found no signs of impact or degradation attributable to the production system.
1534953048 2018-08-22 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: The well was in active production. The load lines were plugged and secure. The secondary containment was intact and dry with no signs of leaks or spills. Fittings and connections at the wellhead and battery were secure and free from leakage or problems. I walked the areas surrounding the wellhead and battery which are comprised of wild vegetated areas with piles of gravel and slag stored variously throughout, and found no signs of impact or degradation attributable to the production system.

For data sources see[9]