If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-035-22069 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.46,"lon":-81.51,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: AM-TEK OIL INC | |
Well Pad ID: | |
Farm/Lease Name: D & D UNIT | |
License Status: Producing | |
License Date: 2008-09-23 | |
Spud Date: 2008-10-20 | |
Spud Drilling Contractor: H A D INC | |
Final Drill Date: 2008-10-27 | |
Well Total Depth: 3745.00 ft | |
Configuration: Vertical | |
Latitude: 41.460000 | |
Longitude: -81.510000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2008-09-23 | Proposed Formations:ORISKANY/CLINTON, Issued Date:9/23/2008, Expired Date:9/23/2009 6:00:00 AM, Drilling unit acres:23.98, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2008-10-27 | |
Completion Report Received | 2008-11-14 | |
Construction Permit Expires | 2009-09-23 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2008-12-30 | 3539 | 3606 | 62 |
3539 | 3606 | 62 | |
3539 | 3606 | 62 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 80000 Gal | 40000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2009 | DUCK CREEK ENERGY INC | 4603.00 | 785.00 | 295 |
2010 | DUCK CREEK ENERGY INC | 14541.00 | 1105.00 | 365 |
2011 | DUCK CREEK ENERGY INC | 15433.00 | 897.00 | 365 |
2012 | DUCK CREEK ENERGY INC | 12793.00 | 572.00 | 366 |
2013 | DUCK CREEK ENERGY INC | 9855.00 | 559.00 | 365 |
2014 | DUCK CREEK ENERGY INC | 8302.00 | 463.00 | 365 |
2015 | DUCK CREEK ENERGY INC | 8064.00 | 419.00 | 365 |
2016 | DUCK CREEK ENERGY INC | 6912.00 | 269.00 | 365 |
2017 | DUCK CREEK ENERGY INC | 5913.00 | 349.00 | 365 |
2018 | DUCK CREEK ENERGY INC | 5654.00 | 324.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2009 | DUCK CREEK ENERGY INC | Brine | 609 | 295 |
2010 | DUCK CREEK ENERGY INC | Brine | 619 | 365 |
2011 | DUCK CREEK ENERGY INC | Brine | 326 | 365 |
2012 | DUCK CREEK ENERGY INC | Brine | 218 | 366 |
2013 | DUCK CREEK ENERGY INC | Brine | 180 | 365 |
2014 | DUCK CREEK ENERGY INC | Brine | 130 | 365 |
2015 | DUCK CREEK ENERGY INC | Brine | 115 | 365 |
2016 | DUCK CREEK ENERGY INC | Brine | 90 | 365 |
2017 | DUCK CREEK ENERGY INC | Brine | 52 | 365 |
2018 | DUCK CREEK ENERGY INC | Brine | 65 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1395017389 | 2009-4-22 0:00: | DD | No Violations | |
-1726633468 | 2008-10-21 0:00 | DD | No Violations | |
-1839922266 | 2014-6-19 0:00: | UP | No Violations | |
-1879241413 | 2009-1-23 0:00: | DD | No Violations | |
-1930006662 | 2013-2-19 0:00: | PL | No Violations | |
-1973895958 | 2008-10-27 0:00 | DD | No Violations | |
-2103360872 | 2008-11-3 0:00: | DD | No Violations | |
-854221063 | 2017-8-10 0:00: | UP | No Violations | 0.50 |
-863077707 | 2008-10-22 0:00 | DD | No Violations | |
-931776754 | 2017-10-20 0:00 | UP | No Violations | 1.50 |
0091664835 | 2008-12-01 | Drill / Deepen / Reopen | No Violations | pits closed service rig on site |
0581766028 | 2018-01-08 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. The well and battery are located behind a multi-tenant strip, with mixed-used commercial use beyond. At the time of this inspection I noted the following: a well with plunger-lift system and associated tank battery is separate board-on-board enclosures which were locked and secure. The load-line valves were plugged, locked and secure. The secondary containment was intact. The production reports were current. The well was producing with an active chart record. I walked and inspected the areas surrounding the well and battery and found no indications of problems. |
0854221063 | 2017-08-10 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with plunger lift system and associated tank battery in separate board-on-board enclosures in a commercial shopping and dining district. The enclosure gates were locked. The load line valves were secure. The secondary containment was intact. Fittings and connections at the wellhead and battery were secure. The surrounding areas are comprised of asphalt parking and managed greenscape. I did note the following issue of concern: the former location of the drilling pits was exhibiting heaving of the asphalt pavement. I met with the property manager who reported that the heaving had been occurring since at least 2015. |
0863077707 | 2008-10-22 | Drill / Deepen / Reopen | No Violations | surface cementing |
0931776754 | 2017-10-20 | UrbanProduction Wells | No Violations | I Inspected this well location as a follow-up to a previous inspection in which I had noted heaving in the former location of the drilling pits. The asphalt paving was heaved up several inches along the axis of the former drilling pits. I had notified the well owner and we had discussed needed mitigation. At the time of the this inspection, crews were actively working to remove the asphalt paving and re-grade the sub course material as restoration of the heaving. These activities continued during my inspection visit. |
1395017389 | 2009-04-22 | Drill / Deepen / Reopen | No Violations | no violation at site |
1580866577 | 2012-01-12 | UrbanPreliminary Restoration | No Violations | On 01/12/2012, DNR Inspector Richard Skidmore completed an urban preliminary restoration well inspection for DNR Inspector Ray Wallace. The lease road, tank battery, and well head locations are in compliance with 1501:9-9-05. Inspection passed. |
1726633468 | 2008-10-21 | Drill / Deepen / Reopen | No Violations | Conductor cementing |
1839922266 | 2014-06-19 | UrbanProduction Wells | No Violations | I inspected this producing unit as part of routine inspection activity. Production reports are current. I did not observe any signs or evidence of leakage, spill , or problems at either the production wellhead or tank battery system. The wellhead and battery are located within the asphalt-paved parking area behind the professional office building at 23360 Chagrin Blvd. The secondary containment at the battery which is comprised of 24 high masonry block, is in good condition. The process safety equipment is present. Tank hatch lids are closed. Load lines are bull-plugged and locked. Gates are intact and locked. Signage is present, accurate, and readable. The interior diked area is lined with sorted limestone gravel which is free from standing water or weeds. I observed no problems or issues requiring attention. |
1879241413 | 2009-01-23 | Drill / Deepen / Reopen | No Violations | company working on well site and tank battery |
1930006662 | 2013-02-19 | Preliminary Restoration | No Violations | The wellhead consists of a mechanical plunger lift unit in an 8-foot fenced enclosure. The 8 5/8-inch casing does not indicate any pressure at the gauge. The associated tank battery consists of 1 100-barrel (BBL) tank, 1 50 BBL tank. The mechanical separator is located in a separate, locked enclosure.. The spacing is in accordance with the rule. The tank battery dike is adequate. Safety gear in place as required by 1501:9-9-05. |
1973895958 | 2008-10-27 | Drill / Deepen / Reopen | No Violations | running 4.5 |
2103360872 | 2008-11-03 | Drill / Deepen / Reopen | No Violations | pits closed area leveled |
581766028 | 2018-1-8 0:00:0 | UP | No Violations | 0.50 |
91664835 | 2008-12-1 0:00: | DD | No Violations |
For data sources see[9]