If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-035-22144 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.33,"lon":-81.71,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: EOS ENERGY LLC | |
Well Pad ID: | |
Farm/Lease Name: ABIDING SAVIOR | |
License Status: Producing | |
License Date: 2010-07-27 | |
Spud Date: 2010-04-08 | |
Spud Drilling Contractor: WILDCAT DRILLING | |
Final Drill Date: 2010-04-14 | |
Well Total Depth: 3675.00 ft | |
Configuration: Vertical | |
Latitude: 41.330000 | |
Longitude: -81.710000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2010-02-11 | Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:2/11/2010, Expired Date:2/11/2011 6:00:00 AM, Drilling unit acres:31.713, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2010-04-14 | IP BASED ON REGIONAL AVERAGE |
APP | 2010-07-27 | Proposed Formations:OHIO SHALE/CLINTON, Issued Date:7/27/2010, Expired Date:7/26/2012 12:00:00 PM, Drilling unit acres:26.1749, Proposed Well Type:OG, Proposed Well Class:POOL |
Completion Report Received | 2010-09-22 | IP BASED ON REGIONAL AVERAGE |
Construction Permit Expires | 2011-07-27 | IP BASED ON REGIONAL AVERAGE |
Change of Owner | 2018-07-31 | Operator changed from 1249, CUTTER OIL COMPANY to 10185, EOS ENERGY LLC |
Record Last Modified | 2018-07-31 | IP BASED ON REGIONAL AVERAGE |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2010-11-09 | 3419 | 3452 | 93 |
3419 | 3452 | 93 | |
3419 | 3452 | 93 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 90000 Gal | 0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2010 | CUTTER OIL COMPANY | 13817.00 | 7992.00 | 233 |
2011 | CUTTER OIL COMPANY | 46399.00 | 6758.00 | 365 |
2012 | CUTTER OIL COMPANY | 31178.00 | 3731.00 | 366 |
2013 | CUTTER OIL COMPANY | 16152.00 | 2267.00 | 365 |
2014 | CUTTER OIL COMPANY | 12675.00 | 2320.00 | 365 |
2015 | CUTTER OIL COMPANY | 9391.00 | 1459.00 | 365 |
2016 | CUTTER OIL COMPANY | 8972.00 | 1860.00 | 365 |
2017 | CUTTER OIL COMPANY | 7205.00 | 1449.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2010 | CUTTER OIL COMPANY | Brine | 2473 | 233 |
2011 | CUTTER OIL COMPANY | Brine | 237 | 365 |
2012 | CUTTER OIL COMPANY | Brine | 229 | 366 |
2013 | CUTTER OIL COMPANY | Brine | 120 | 365 |
2014 | CUTTER OIL COMPANY | Brine | 135 | 365 |
2015 | CUTTER OIL COMPANY | Brine | 67 | 365 |
2016 | CUTTER OIL COMPANY | Brine | 35 | 365 |
2017 | CUTTER OIL COMPANY | Brine | 115 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1165633235 | 2010-5-6 0:00:0 | DD | No Violations | |
-1301609388 | 2018-1-30 0:00: | UP | No Violations | 0.50 |
-1345246557 | 2020-1-27 0:00: | UP | No Violations | |
-1765191289 | 2015-5-7 0:00:0 | UP | No Violations | |
-1806714223 | 2018-10-16 0:00 | UP | No Violations | |
-201357600 | 2010-4-10 0:00: | DD | No Violations | |
-2067389574 | 2015-6-24 0:00: | UP | No Violations | |
-260873467 | 2010-1-4 0:00:0 | AM | No Violations | |
-798564664 | 2019-5-6 0:00:0 | PW | No Violations | |
-820513439 | 2010-4-13 0:00: | DD | No Violations | |
-971778262 | 2017-4-27 0:00: | UP | No Violations | 0.50 |
0065269250 | 2015-01-29 | UrbanProduction Wells | No Violations | I inspected this producing unit as part of routine inspection activity. The wellhead pump jack enclosure is secure. Valves and connections are secure and free from signs of leakage or problems. At the time of my inspection, the area is covered with several inches of snow. Access to the well and battery is from the church parking lot which is clear and snow has been plowed. Load-outs are bull-plugged and locked. I did not observe any problems at the time of this inspection. |
0201357600 | 2010-04-10 | Drill / Deepen / Reopen | No Violations | Bop Tested and Passed. |
0260873467 | 2010-01-04 | Administrative Inspection | No Violations | Held on site meeting to discuss the site construction and permit condition. |
0314647302 | 2010-03-16 | Drill / Deepen / Reopen | No Violations | No Violation Company on site making location Silt fence up, Trees cut and chipped . |
0617373070 | 2011-09-07 | UrbanPreliminary Restoration | No Violations | Well inspected, no violations found. Well is in compliance .Urban Preliminary Restoration passed. |
0798564664 | 2019-05-06 | Production Wells | No Violations | I conducted an inspection of the well and found no violation at well or tank battery. |
0820513439 | 2010-04-13 | Drill / Deepen / Reopen | No Violations | cemented 4.5 casing |
0971778262 | 2017-04-27 | UrbanProduction Wells | No Violations | I inspected this producing well location as part of routine inspection activity. At the time of this inspection, I noted the following: a wellhead with pump-jack system and associated tank battery in separate board-on-board enclosures. The enclosure gates were locked and secure. Fittings and connections at the wellhead were secure. The surface casing pressure was being monitored and showed no pressure. The electrical panel box was locked and secure. The pump jack supports were solid and level. The bridle was secure. The stuffing box fitting was free from leakage. Fittings and connections at the battery were secure. The load-line valves were plugged and locked. The tank lids were closed and sealed. The secondary containment drain was secure. The short gravel-paved access road that extends north from the church parking lot was level and dry. I walked the areas surrounding the well and battery systems and observed the natural soils and vegetation to be free from signs of leaks, spills, or other adverse impact from the on-going production activity. |
1165633235 | 2010-05-06 | Drill / Deepen / Reopen | No Violations | well being situlated no violation. |
1271095045 | 2010-04-10 | Drill / Deepen / Reopen | No Violations | Bop test 1:30 Am to 5:30Am 4-10-2010 |
1301609388 | 2018-01-30 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. The well and battery are located on the grounds of the Abiding Savior Church. At the time of this inspection, I observed the following: the fittings and connections at the wellhead pump jack system and the battery were secure. The tank lids were closed and secure. The load-lines were secure, plugged and locked. The secondary containment was intact and free from signs of leakage. The individual enclosure gates were locked and secure. I walked and inspected the areas surrounding the well and battery and found no overt or observable signs of environmental impact. The surrounding areas were covered in several inches of new snow. The production reports were current. Bonding and insurance for this owner were current. |
1378415692 | 2013-09-05 | UrbanPreliminary Restoration | No Violations | The producing unit consists of a producing wellhead with pumpjack and aboveground storage tank battery. The wellhead and tank battery are enclosed in separate board-on-board fences. The battery is comprised of two 100-barrel production tanks and one 20-barrel brine tank. The secondary containment is good. 1501:9-9-05E safety equipment is present. |
1467934178 | 2010-04-08 | Drill / Deepen / Reopen | No Violations | cemented conductor casing. |
1619348946 | 2014-02-20 | UrbanProduction Wells | No Violations | The unit is producing with no changes observed since the last inspection. No violations or problems. |
1622891156 | 2013-09-11 | UrbanProduction Wells | No Violations | The producing unit consists of a production wellhead with pumpjack unit and aboveground storage tank battery. The battery includes one steel 2 100-barrel production tanks, 1 20-barrel brine tank, Dominion metering run, and separator. Tank spacing is in accordance with the rules. The battery and wellhead are enclosed in separate board-on-board enclosures which are locked. The unit ID is present at the battery and wellhead. Spacing is in accordance with rules and safety equipment is present. I did not observe any problems or signs of spills or leakage. |
1765191289 | 2015-05-07 | UrbanProduction Wells | Violations Noted | I was on site to conduct a status check of this well with DOGRM Inspector - John Fleming and District Manager - Rick Anderson. The wellhead is equipped with a pumpjack and the valves on the wellhead were open. Identification signs are present on the tank battery and wellhead fences, but are not urban rule compliant. There is oil leaking around the wellhead, and is coming from the polish rod. The oil stain measured 5X8 feet at the time of the inspection. There was an open 5 gallon bucket full of oil next to the wellhead. The tank battery consisted of 2-140 BBL production tanks, mechanical separator, and a 1500 gallon poly brine tank. The production tank sealable hatches are not secured properly. The vent stacks are equipped with pressure relief valves, but no spark arrestors. There is a charcoal filter. The tank pick-up line valves have flat plugs but are not locked and the locks were hanging from the catwalk brackets on the tanks. The brine tank is seeping at the valve connection. The pick-up lines have oil staining at the base and are not locked. The well and tank battery were fenced with 8-foot board-on-board fencing, and the man doors were locked. The lease road is stable and drivable. The following needs completed by:
1) Clean-up all spilled oil/brine in tank battery and remove any containers containing fluid (6-16-15) 2) Insert plugs/or add locks into the tank valves and pick-up lines (6-16-15) 3) Install lightning arrestors on vent stacks (6-16-15) 4) Add additional identification sign information as required by 1501:9-9-05 (E) |
1806714223 | 2018-10-16 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection and evaluation of current condition following recent change in ownership. At the time of this inspection, I noted the following:. the well was in active production. The enclosure gates were locked and secure. The identification was current and accurate. The load-line valves were plugged and locked. Tank lids were closed and sealed. I walked the areas surrounding the well and battery and found no signs of problems or indications of impact. |
2067389574 | 2015-06-24 | UrbanProduction Wells | No Violations | I inspected this well as a follow-up to a previous Compliance Notice. Load lines are now lock-protected. Tank lids are sealed and secure. Electrical boxes are locked and secure. Process safety gear, including spark arrestor is present. Secondary containment at the well and battery are intact. The oil staining has been mitigated. Update of signage is in progess. |
2068704525 | 2010-04-09 | Drill / Deepen / Reopen | No Violations | cementing surface good returns to surface. |
2140109833 | 2017-11-28 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. The well and battery are located at the rear portion of a church property, at the edge of the parking and drive areas. At the time of this inspection, I observed the following: the fittings and connections at the wellhead pump jack system and the battery were secure. The tank lids were closed and secure. The load-lines were secure, plugged and locked. The secondary containment was intact and free from signs of leakage. The enclosure gates were locked and secure. The shared-use access consists of asphalt-paved drive-way and parking for the church. I walked and inspected the areas surrounding the well and battery and found no overt or observable signs of environmental impact. The production reports were current. Bonding and insurance for this owner were current. |
2143640639 | 2010-04-12 | Drill / Deepen / Reopen | No Violations | Drilling at 1820. Walked perimeter with gas meter no gas reading on meter Site in compliance with HB278. |
314647302 | 2010-3-16 0:00: | DD | No Violations | |
617373070 | 2011-9-7 0:00:0 | UL | No Violations | |
65269250 | 2015-1-29 0:00: | UP | No Violations | 0.50 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1765191289 | US-OH-117550 | 2015-06-08 | LOCKS | |
1765191289 | US-OH-117551 | 2015-06-08 | TANKS (a-i) | |
1765191289 | US-OH-117552 | 2015-06-08 | Well operation causing pollution and contamination |
For data sources see[9]