{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.33,"lon":-81.8,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: SOUND ENERGY CO INC | |
Well Pad ID: | |
Farm/Lease Name: M WITTENMYER | |
License Status: Producing | |
License Date: 2012-05-17 | |
Spud Date: 2012-06-12 | |
Spud Drilling Contractor: POULSON DRILLING | |
Final Drill Date: 2012-06-17 | |
Well Total Depth: 3185.00 ft | |
Configuration: Vertical | |
Latitude: 41.330000 | |
Longitude: -81.800000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2011-01-07 | Proposed Formations:CLINTON, Issued Date:1/7/2011, Expired Date:1/6/2013 12:00:00 PM, Drilling unit acres:20.58, Proposed Well Type:OG, Proposed Well Class:POOL |
APP | 2011-01-14 | Proposed Formations:CLINTON, Issued Date:1/14/2011, Expired Date:1/13/2013 12:00:00 PM, Drilling unit acres:20.58, Proposed Well Type:OG, Proposed Well Class:POOL |
APP | 2012-05-17 | Proposed Formations:CLINTON, Issued Date:5/17/2012, Expired Date:5/17/2014 12:00:00 PM, Drilling unit acres:20.58, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2012-06-17 | |
Completion Report Received | 2012-09-24 | |
Construction Permit Expires | 2013-05-17 | |
Change of Owner | 2015-11-03 | Operator changed from 7626, M & M ROYALTY LTD to 9312, FO ENERGY LLC |
Change of Owner | 2019-04-23 | Operator changed from 9312, FO ENERGY LLC to 4327, SOUND ENERGY CO INC |
Record Last Modified | 2019-04-23 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2012-09-27 | 2977 | 2990 | 27 |
2012-09-27 | 2996 | 3000 | 9 |
2977 | 2990 | 27 | |
2996 | 3000 | 9 | |
2977 | 2990 | 27 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2012-08-22 | H2O | 0 | 50525 Gal | 50000 | Universal Well Services Inc. |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2012 | M & M ROYALTY LTD | 0.00 | 0.00 | 0 |
2013 | M & M ROYALTY LTD | 0.00 | 110.00 | 60 |
2014 | M & M ROYALTY LTD | 3453.00 | 1088.00 | 365 |
2015 | M & M ROYALTY LTD | 3434.00 | 518.00 | 304 |
2016 | FO ENERGY LLC | 3149.00 | 439.00 | 366 |
2017 | FO ENERGY LLC | 2094.00 | 381.00 | 365 |
2018 | FO ENERGY LLC | 2126.00 | 497.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2012 | M & M ROYALTY LTD | Brine | 0 | 0 |
2013 | M & M ROYALTY LTD | Brine | 45 | 60 |
2014 | M & M ROYALTY LTD | Brine | 238 | 365 |
2015 | M & M ROYALTY LTD | Brine | 238 | 304 |
2016 | FO ENERGY LLC | Brine | 344 | 366 |
2017 | FO ENERGY LLC | Brine | 154 | 365 |
2018 | FO ENERGY LLC | Brine | 381 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1120987475 | 2018-4-13 0:00: | UP | No Violations | 1.00 |
-1303283728 | 2012-6-11 0:00: | UD | No Violations | |
-312632495 | 2012-6-13 0:00: | DD | No Violations | 3.00 |
-54215457 | 2014-7-7 0:00:0 | UP | No Violations | |
0054215457 | 2014-07-07 | UrbanProduction Wells | No Violations | I inpected this producing unit as part of routine inspection activity and also as a follow-up to my last inspection. At the time of my last inspection, production of this unit had been stopped temporarily pending resolution of a technical problem with the metering connection with Columbia Gas. The well is currently still idle pending the solution. I did not observe any problems, leaks, spills, or other issues. |
0312632495 | 2012-06-13 | Drill / Deepen / Reopen | No Violations | My visit to the well was to witness the cementing of the surface casing. Cement reports will be filed upon completion of the well drilling process. I also witnessed the Blow Off Preventer test on the evening of 06/13/2012. |
1120987475 | 2018-04-13 | UrbanProduction Wells | No Violations | I inspected this well as part of routine inspection activity. At the time of this inspection, I observed the following: one wellhead with pump jack system in a chain-link enclosure and battery in a separate chain-link enclosure. The enclosure gates were locked and secure. Fittings and connections at both the wellhead and the battery were secure and free from leakage or problems. The tank lids were closed and sealed. The load-line valves were plugged and locked. Signage was present, indicating the new owner/operator. Secondary containment was intact. The dedicated access road was in good condition. |
1299519894 | 2011-01-11 | Administrative Inspection | No Violations | Held on site meeting to discuss permit conditions and site construction. |
1303283728 | 2012-06-11 | Urban Drill / Deepen / Reopen | No Violations | My visit to the well was to inspect well site construction and rig move on and set up. Best Management Practices for site construction are being employed, in addition pre permit conditions are being adhered to. Rig is on site and is beginning to rig up. |
1339450379 | 2012-06-17 | Urban Drill / Deepen / Reopen | No Violations | My visit to the well today was to witness cementing of production casing. From home to site and return encompassed 4 hours. Cement report to follow completion of well. |
1371998397 | 2012-06-13 | Urban Drill / Deepen / Reopen | No Violations | My inspection found the rig shut down and waiting for cement to set. They will conduct the Blow Out Preventor test later tonight (tentative time of 8 PM). DNR Inspector Ray Wallce is schduled to witness this test. No violations found. |
1378400337 | 2013-09-05 | UrbanPreliminary Restoration | No Violations | The producing unit consists of a producing wellhead with pumpjack and aboveground storage tank battery. The wellhead and tank battery are enclosed in separate chain-link fences. The battery is comprised of three 100-barrel production tanks and one 50-barrel brine tank. The secondary containment is good. 1501:9-9-05E safety equipment is present. There is no screening at the wellhead or battery. This will be required if not already waived. Preliminary restoration is pending verification. |
1385402919 | 2013-11-25 | UrbanProduction Wells | No Violations | This unit reportedly has been shut-in following a valve failure at the sales line which caused oil to infiltrate Columbia Gas distribution network. M & M has requested an allowance to operate a flare on a temporary basis which would allow them to continue to produce oil from the unit. |