X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-073-23584

Well Details

Well ID: 34-073-23584
Loading map...
Country: United States
State: Ohio
County: Hocking
Municipality: Good Hope Township
Operator Name: COLUMBIA GAS TRANSMISSION LLC
Well Pad ID:
Farm/Lease Name: LEHR WARREN C ETAL
License Status: Storage Well
License Date: 2009-05-06
Spud Date: 2009-06-17
Spud Drilling Contractor: KILBARGER DRLG
Final Drill Date: 2009-06-20
Well Total Depth: 2625.00 ft
Configuration: Vertical
Latitude: 39.600000
Longitude: -82.500000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2009-05-06 Proposed Formations:CLINTON, Issued Date:5/6/2009, Expired Date:5/6/2010 6:00:00 AM, Drilling unit acres:173, Proposed Well Type:SO, Proposed Well Class:STOR
Reached Total Depth 2009-06-20
Completion Report Received 2009-09-02
Construction Permit Expires 2010-05-06
Record Last Modified 2015-09-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-12-15 2514 2536 132
2514 2536 132
2514 2536 132

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 234 Bbl 35000 401M SCF NITROGEN ASSIST

For data sources see[4]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1227480116 2014-12-23 0:00 SO No Violations 0.30
-1285001639 2017-10-31 0:00 SO No Violations 0.50
-1473347748 2020-2-4 0:00:0 SO No Violations 0.20
-1701430803 2019-3-28 0:00: SO No Violations 0.30
-1981047494 2009-10-30 0:00 PL No Violations
0412512241 2011-12-29 Storage Well No Violations No violations at the time of inspection.
1227480116 2014-12-23 Storage Well No Violations Storage well inspection. The well has a legible identification, no violation noted.
1285001639 2017-10-31 Storage Well No Violations On the day of this inspection, I found a storage well consisting of a wellhead and a drip. Legible identification on wellhead, no violations noted, GPS was taken on day of inspection.
1438000792 2015-07-27 Storage Well No Violations Storage well inspection. Legible well identification found at well. No violations found on date of inspection.
1519281578 2009-06-19 Drill / Deepen / Reopen No Violations Checked on status of drilling rig. No violations at this time.
1532607872 2018-07-26 Storage Well No Violations I conducted a storage well inspection on this well today. I observed identification at the well. I did not observe any violations. Time of inspection: 8:15 AM. Weather: 68 degrees F, Sunny
1556281295 2019-04-26 Storage Well No Violations My inspection revealed that identification has been posted at the well. The violation has been resolved. Time of inspection: 8:10 AM. Weather: 56 degrees F, Rain
1634616207 2019-04-17 Storage Well No Violations My inspection revealed that the well identification was incomplete. I contacted the well tender Ryan Henry at 9:10 AM and advised him that identification needs to be posted at the well. Time of inspection: 8:35 AM. Weather: 60 degrees F, Partly cloudy
1701430803 2019-03-28 Storage Well No Violations I conducted a storage well inspection on the Lehr #12503 well today. The wellhead was equipped with a master gate valve, wing gate valve, and two valves on the 8.63 inch casing head. An identification sticker at the drip was faded and not legible. The well owner shall post legible identification at the well within 10 days. I left a voicemail message for the well tender Ryan Henry at 3:37 PM. Time of inspection: 12:35 PM. Weather: 64 degrees F, Cloudy
1922097424 2009-06-18 Drill / Deepen / Reopen No Violations Witnessed surface job. Good returns were observed, but cement did not stay at surface. Waited and topped off with additional cement slurry and flake. Cement stayed at the surface.
1944940876 2009-06-16 Drill / Deepen / Reopen No Violations An inspection revealed no violations at this time. Silt fencing had been installed around the location and alongside the lease road. The drilling pits are acceptable and fluid level kept low.
1967398596 2014-02-07 Storage Well No Violations Storage well inspection, no violations noted.
1981047494 2009-10-30 Preliminary Restoration No Violations An inspection of the well site revealed good vegetative cover, drilling equipment removed, gravel lease road and pits closed. The Preliminary Restoration meets requirements. GPS reading obtained for storage well.
412512241 2011-12-29 0:00 SO No Violations 0.50

For data sources see[5]

References