34-155-21644

Well Details

Well ID: 34-155-21644
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Brookfield Township
Operator Name: VORTEX ENERGY LLC
Well Pad ID:
Farm/Lease Name: REDA R& L
License Status: Producing
License Date: 1980-12-05
Spud Date: 1980-12-18
Spud Drilling Contractor:
Final Drill Date: 1981-01-04
Well Total Depth: 4948.00 ft
Configuration: Vertical
Latitude: 41.270000
Longitude: -80.570000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1980-12-05 54 TITAN ENERGY CORP GeoDate 12/5/80
Original Spud 1980-12-18
Completed 1981-01-04
Reached Total Depth 1981-01-04
Change of Owner 1998-01-26 Operator changed from 54, TITAN ENERGY CORP to 1333, BARR ROBT/dba BIG SKY PET
Change of Owner 2017-06-22 Operator changed from 1333, BIG SKY ENERGY INC to 9841, VORTEX ENERGY LLC
Record Last Modified 2017-06-22

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 4760 4834 16
4760 4834 16
4760 4834 16

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 200070 0 SCF N2
H2O 0 76240 Gal 68000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 TITAN ENERGY CORP 8937.00 54.00 0
1985 TITAN ENERGY CORP 6194.00 56.00 365
1986 TITAN ENERGY CORP 4575.00 61.00 365
1987 TITAN ENERGY CORP 3598.00 67.00 365
1988 TITAN ENERGY CORP 4896.00 0.00 365
1989 TITAN ENERGY CORP 0.00 3342.00 365
1990 TITAN ENERGY CORP 2116.00 57.00 365
1991 TITAN ENERGY CORP 2752.00 44.00 365
1992 TITAN ENERGY CORP 4822.00 73.00 365
1993 TITAN ENERGY CORP 4164.00 0.00 365
1994 TITAN ENERGY CORP 1936.00 0.00 365
1997 TITAN ENERGY CORP 2511.00 15.00 245
2000 BIG SKY ENERGY INC 2296.00 62.00 365
2001 BIG SKY ENERGY INC 2788.00 0.00 365
2002 BIG SKY ENERGY INC 2246.00 42.00 365
2003 BIG SKY ENERGY INC 3408.00 0.00 365
2004 BIG SKY ENERGY INC 4372.00 0.00 365
2005 BIG SKY ENERGY INC 2337.00 0.00 365
2006 BIG SKY ENERGY INC 2788.00 53.00 365
2007 BIG SKY ENERGY INC 2890.00 0.00 365
2008 BIG SKY ENERGY INC 242.00 0.00 365
2009 BIG SKY ENERGY INC 2452.00 0.00 365
2010 BIG SKY ENERGY INC 2603.00 0.00 365
2011 BIG SKY ENERGY INC 2024.00 16.00 365
2012 BIG SKY ENERGY INC 1541.00 0.00 366
2013 BIG SKY ENERGY INC 1992.00 0.00 365
2014 BIG SKY ENERGY INC 2012.00 12.00 365
2016 BIG SKY ENERGY INC 801.00 0.00 98
2017 BIG SKY ENERGY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 TITAN ENERGY CORP Brine 0 0
1985 TITAN ENERGY CORP Brine 0 365
1986 TITAN ENERGY CORP Brine 0 365
1987 TITAN ENERGY CORP Brine 0 365
1988 TITAN ENERGY CORP Brine 0 365
1989 TITAN ENERGY CORP Brine 0 365
1990 TITAN ENERGY CORP Brine 0 365
1991 TITAN ENERGY CORP Brine 0 365
1992 TITAN ENERGY CORP Brine 0 365
1993 TITAN ENERGY CORP Brine 0 365
1994 TITAN ENERGY CORP Brine 66 365
1997 TITAN ENERGY CORP Brine 245
2000 BIG SKY ENERGY INC Brine 0 365
2001 BIG SKY ENERGY INC Brine 0 365
2002 BIG SKY ENERGY INC Brine 0 365
2003 BIG SKY ENERGY INC Brine 0 365
2004 BIG SKY ENERGY INC Brine 0 365
2005 BIG SKY ENERGY INC Brine 0 365
2006 BIG SKY ENERGY INC Brine 0 365
2007 BIG SKY ENERGY INC Brine 0 365
2008 BIG SKY ENERGY INC Brine 0 365
2009 BIG SKY ENERGY INC Brine 0 365
2010 BIG SKY ENERGY INC Brine 0 365
2011 BIG SKY ENERGY INC Brine 0 365
2012 BIG SKY ENERGY INC Brine 0 366
2013 BIG SKY ENERGY INC Brine 0 365
2014 BIG SKY ENERGY INC Brine 57 365
2016 BIG SKY ENERGY INC Brine 0 98
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-2063697872 2014-10-8 0:00: AM No Violations
-509349076 2016-9-15 0:00: PW No Violations 0.50
0000PL4098 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0236634051 2016-06-02 Production Wells No Violations Follow-up to Compliance Notice #1462196767 issued on 5/2/2016 due to pollution and contamination issues found at the tank battery and failure to post the required identification. My inspection found the valve on the flow line from the wellhead to the separator closed. The domestic tap at the wellhead was open at this time. The production chart indicated pressure at the separator and the inflow and outflow valves are open. The stenciled ID sign on the 100 barrel tank has been updated with the required information and satisfies Chapter 1501:9-9-05(A) of the Ohio Administrative Code. An inspection of the affected area on the southwest side of the 100 barrel tank found that none of the remedial activities required by the prior Compliance Notice have been undertaken to address the pollution and contamination issues within the tank battery. Big Sky Energy Incorporated continues to be in violation of Chapter 1501:9-1-07 of the Ohio Administrative Code and Chapter 1509.22(A) of the Ohio Revised Code. Note: I spoke with the landowner during my inspection and he informed me that his house gas was shut off without any notification and that he was responsible for turning it back on. He also stated that the operator has made no royalty interest payments to him in several years.
0509349076 2016-09-15 Production Wells No Violations
1270224903 2014-02-28 Production Wells No Violations My inspection today is a follow-up inspection to Compliance Notice # 1393419182, which was issued for non-compliance of Chiefs Order # 2014-43. My inspection found the well to be equipped with a plunger lift unit. The demco valve and the valve leading to the flow line on the wellhead are open. There is a domestic line producing off of the 4.5 casing. The tank battery consists of a 100 BBL production tank and a 50 BBL brine tank that is surrounded by a proper dike. The heat treated separator has the proper spacing. The flow line valve leading into the separator is currently open. The sales line valve leading out of the separator is currently open. The production chart in the separator shows the well is still being produced since my last inspection on 2-25-2014. The proper identification was located on the tank battery. The lease road is in stable condition. The well is in production which is in non-compliance of Chiefs Order # 2014-43. The well must be shut-in immediately.
1393419182 2014-02-25 Production Wells Violations Noted I was on location today with O.D.N.R. Supervisor Tom Hill to check compliance on Chiefs Order # 2014-43. My inspection found the well to be equipped with a plunger lift unit. The demco valve and the valve leading to the flow line on the wellhead are open. There is a domestic line producing off of the 4.5 casing. The tank battery consists of a 100 BBL production tank and a 50 BBL brine tank that is surrounded by a proper dike. The heat treated separator has the proper spacing. The flow line valve leading into the separator is currently open. The sales line valve leading out of the separator is currently open. The production chart in the separator shows the well has been produced since the last chart change on 2-24-2014. The well was in the middle of a production cycle while I was on location. The proper identification was located on the tank battery. The lease road is in stable condition. The well is in production which is in non-compliance of Chiefs Order # 2014-43. The well must be shut-in immediately.
1419355966 2014-12-16 Production Wells No Violations I was on location for a status check inspection. During my inspection, I found the well in production. The well was equipped with a plunger lift assembly. A domestic gas line came off of the 4.5 casing. The tank battery consisted of a 100 barrel production tank, a 50 barrel brine tank and separator. A dike surrounded the tanks. A stenciled identification sign was properly posted on the production tank. There was a bull plug on the load line. The lease road was in stable condition.
1462196767 2016-04-18 Production Wells Violations Noted I conducted this inspection to follow---105 requiring Big Sky Energy Incorporated to suspend all oil and gas operations in the State of Ohio. My inspection found the wellhead equipped with a 1.5 plunger lift system. The gate valve and tubing flow line valve were open and a domestic tap was on and charged at 18psi. The well is producing to a horizontal separator and the flow line and sales line valves are open. The 31 day production chart in the separator was changed on 2-29-2016 and is currently recording production and over printing the previous month. The plunger lift timer is running and set to cycle in three (3) hours. A gauge at the separator indicates 68psi and I can hear gas moving through the pressure vessel. The well produces to a diked tank battery containing one (1) 100 barrel production tank and one (1) 50 barrel brine tank. The ID on the tank is insufficient as the well name, well number, and emergency contact number are worn off and not legible. The dump line from the separator to the 100 barrel tank has no integrity where it attaches to the top of the tank and has leaked/overflowed 8-10 gallons of crude oil onto the ground inside the tank battery. The oil has pooled in a 3 X 3 area at the base of the tank on the southwest side and is required to be cleaned up within one (1) week of the issuance of this notice. Big Sky Energy Incorporated has failed to comply with the above orders to suspend oil and gas operations in the State of Ohio and shall immediately cease the production operations of this well as required by the temporary restraining order issued by the Trumbull County Court of Common Pleas, dated 4/11/2016.
2063697872 2014-10-08 Administrative Inspection No Violations The company has received a stay from the chiefs order and is allowed to operate their wells. The compliance notice on the well can be removed.
236634051 2016-6-2 0:00:0 PW No Violations 0.70
PL4098 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1393419182 US-OH-111631 2014-11-17 Failure to register/obtain or maintain bond/insurance
1462196767 US-OH-113394 2016-06-13 Well operation causing pollution and contamination
1462196767 US-OH-113395 2016-06-13 Failure to legibly identify well

For data sources see[9]

References