If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-155-23794 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.19,"lon":-80.99,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Trumbull | |
Municipality: Newton Township | |
Operator Name: HECKMANN WATER RESOURCES (CVR) | |
Well Pad ID: | |
Farm/Lease Name: PANDER R & P (SWIW #16) | |
License Status: Active Injection | |
License Date: 2013-01-31 | |
Spud Date: 2013-03-27 | |
Spud Drilling Contractor: WILDCAT DRILLING | |
Final Drill Date: 2013-04-07 | |
Well Total Depth: 4183.00 ft | |
Configuration: Vertical | |
Latitude: 41.190000 | |
Longitude: -80.990000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2005-10-26 | Proposed Formations:NEWBURG, Issued Date:10/26/2005, Expired Date:10/26/2006 6:00:00 AM, Drilling unit acres:7.955, Proposed Well Type:SWD, Proposed Well Class:SWIW |
APP | 2013-01-31 | Proposed Formations:NEWBURG, Issued Date:1/31/2013, Expired Date:1/31/2015 12:00:00 PM, Drilling unit acres:7.955, Proposed Well Type:SWD, Proposed Well Class:SWIW |
Reached Total Depth | 2013-04-07 | |
Annulus Pressure Monitoring Approved | 2013-04-08 | |
Last Compliance Report | 2013-04-26 | |
Change of Owner | 2013-07-23 | Operator changed from 1258, PANDER RAY TRUCKING INC to 8981, HECKMAN WATER RES(CVR)INC. O&G |
Construction Permit Expires | 2015-01-31 | |
Completion Report Received | 2018-06-01 | |
Record Last Modified | 2018-06-04 |
For data sources see[2]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2013-10-14 | H2O | 0 | 198869 Gal | 0 | Universal Well Services Inc. |
For data sources see[3]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1015760095 | 2018-11-8 0:00: | SW | No Violations | 0.30 |
-1016255905 | 2013-4-2 0:00:0 | DD | No Violations | 5.00 |
-1036683364 | 2013-1-7 0:00:0 | SW | No Violations | |
-105194851 | 2015-12-22 0:00 | SW | No Violations | 0.30 |
-1156172208 | 2017-4-19 0:00: | SW | No Violations | |
-1318293731 | 2017-1-26 0:00: | SW | No Violations | |
-178752135 | 2017-5-22 0:00: | SW | No Violations | |
-1803176271 | 2013-3-26 0:00: | DD | No Violations | |
-1938703032 | 2014-11-13 0:00 | SW | No Violations | |
-1964150001 | 2019-6-10 0:00: | SW | No Violations | 0.30 |
-1999418120 | 2014-4-3 0:00:0 | SW | No Violations | |
-3158804 | 2019-11-21 0:00 | SW | No Violations | 1.20 |
-333795539 | 2014-9-10 0:00: | SW | No Violations | |
-376219122 | 2017-12-4 0:00: | SW | No Violations | 0.30 |
-430207196 | 2015-6-3 0:00:0 | SW | No Violations | |
-832977104 | 2018-8-6 0:00:0 | SW | No Violations | 0.60 |
-993298970 | 2015-6-16 0:00: | SW | No Violations | |
0105194851 | 2015-12-22 | Salt Water Injection Well | No Violations | I was on location to inspect the injection well and facility. The tank battery is in good repair. There is no free oil or water in the dike. The well was not in operations at the time of my inspection. The pump room was in good repair. The well operator was on location. There are no violations at this time. |
0140489283 | 2013-12-03 | Salt Water Injection Well | No Violations | The well was shut-in, because the maximum injection pressure was reached. There were no violations at the time of inspection. |
0149566577 | 2016-12-22 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. The well was found shut-in at the time.
No violations were found. |
0178752135 | 2017-05-22 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. The pump was operating. There were no violations found at the time. |
0198676896 | 2014-07-29 | Salt Water Injection Well | Violations Noted | An inspection found the injection well was not equipped with a 1/4 inch fitting on the tubing/casing annulus. Allen Goodrich was instructed to install a 1/4 inch valve on the casing. |
0246122492 | 2015-03-17 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. There were no violations found at the time. |
0250262502 | 2013-10-23 | Salt Water Injection Well | No Violations | A mechanical integrity test was performed on the flow line. A pressure of 1120 psi. was held on the flow line for fifteen minutes. The test passed. |
0333795539 | 2014-09-10 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. A company representative was instructed to put a minimum pressure of 200 psi. on the tubing/casing annulus. |
0376219122 | 2017-12-04 | Salt Water Injection Well | No Violations | I was on location to inspection the injection well. The facility is in good repair. An identification sign is posted. There was an HWR brine truck on location with the proper UIC number (#407) displayed. There are no violations at this time. |
0430207196 | 2015-06-03 | Salt Water Injection Well | No Violations | The well and surface facility were inspected. The well was found shut-in. There were no violations found at the time of inspection. |
0435602057 | 2017-09-20 | Salt Water Injection Well | No Violations | I was on location to inspect the injection well. The facility is in good repair. I observed no visible leaks. There is a locked gate at the access road entrance. An identification sign is posted. There are no violations at this time |
0548562466 | 2016-07-21 | Salt Water Injection Well | No Violations | The injection well was found shut-in. There were no violations found at the time. |
0552782669 | 2013-03-27 | Drill / Deepen / Reopen | No Violations | My inspection found the drilling depth at 82; no violations. |
0578767101 | 2016-09-12 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. The well was shut-in. There were no violations found at the time. |
0598910368 | 2018-03-22 | Salt Water Injection Well | No Violations | I was on location to inspect the injection well and facility. I found the injection shut- |
0702116830 | 2016-03-31 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. The well was found shut-in. There were no violations found at the time. |
0721069155 | 2014-04-21 | Salt Water Injection Well | No Violations | The well was found shut-in. The well site was graded. |
0737024660 | 2016-05-17 | Salt Water Injection Well | No Violations
3 Frac tanks 1 Injection well | |
0832977104 | 2018-08-06 | Salt Water Injection Well | Violations Noted | I found the injection well not operating on the day of my inspection. I obtained a pressure reading on the injection tubing of 970 psi, which is 50 psi over the maximum allowable pressure. The gate valve on the tubing is in the open position. An identification sign is posted. I observed no leaks or spills. I spoke with Alan Goodrich from NWR. I told Mr. Goodrich a compliance notice would be issued and to address the issue immediately. Mr. Goodrich stated the well would be shut-in and correct the issue. A follow-up inspection will be conducted by 8/7/2018. |
0993298970 | 2015-06-16 | Salt Water Injection Well | No Violations | The well and surface facility were inspected. There were no violations found at the time of inspection. |
1015760095 | 2018-11-08 | Salt Water Injection Well | No Violations | I found the injection not in operation on the day of my inspection. Identification signs are posted. I observed no spills or leaks. |
1016255905 | 2013-04-02 | Drill / Deepen / Reopen | No Violations | I witnessed Universal Well Service cement the conductor casing for Pander Trucking. Wildcat Rig drilled a 22 hole to 94 and set the 16 conductor casing at 86. Universal broke circulation and pumped 380 sacks of cement. They displaced with 16 barrels of fresh water. I did not witness any cement returns to surface. Universal placed 25 bags of cement down the annulus. The cement was tagged more than 15 down the hole. Pander Trucking ordered 8 yards of cement, which was placed down the annulus. Cement was tagged at the surface. |
1036683364 | 2013-01-07 | Salt Water Injection Well | No Violations | The well owner applied for a reissued permit. I inspected the site as part of the pre-permit review. |
1051228135 | 2007-11-14 | Salt Water Injection Well | No Violations | Pre-site inspection . There no water wells or body of water within 500 . |
1067532019 | 2019-01-16 | Salt Water Injection Well | No Violations | I found the injection well not operating on the day of my inspection. An identification sign is posted at the injection well. I observed no leaks or spills. I received a call from Alan Goodrich from HWR. Mr. Goodrich stated the identification sign for the injection well has been made and will be posted this week. |
1117385760 | 2013-04-01 | Drill / Deepen / Reopen | No Violations | The blow-out preventor was tested with 500 psi. of pressure. There was a loss of 20 psi., during 20 minutes. The loss was attributed to a valve on the test line. The test passed. |
1156172208 | 2017-04-19 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. There were no violations found at the time. |
1318293731 | 2017-01-26 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. There were no violations at the time. |
1365426984 | 2013-04-08 | Drill / Deepen / Reopen | No Violations | My inspection found Wildcat rigging down; no violations. |
1388332988 | 2018-01-18 | Salt Water Injection Well | No Violations | I found the injection and facility in good repair on the day of my inspection. I observed no leaks or spills. An identification sign is posted. There are no violations at this time. |
1394646588 | 2019-4-9 0:00:0 | SW | No Violations | 0.30 |
1396626386 | 2014-03-20 | Salt Water Injection Well | No Violations | The well was shut-in. Preliminary restoration will be required when weather permits. |
140489283 | 2013-12-3 0:00: | SW | No Violations | |
1418319672 | 2014-12-10 | Salt Water Injection Well | No Violations | A contractor, Producers Service Corporation, was treating the well with acid. The tubing/casing annulus was pressured up to 504 psi. |
149566577 | 2016-12-22 0:00 | SW | No Violations | |
1513076856 | 2013-04-08 | Salt Water Injection Well | No Violations | A Weatherford AS1X packer was set in compression on 5-1/2 inch casing. A mechanical integrity test was performed on the well. A pressure of 1035 psi. was placed on the 5-1/2 inch and 8-5/8 inch casing annulus. The pressure held without loss for a 15 minute test period. |
1533661433 | 2018-08-07 | Salt Water Injection Well | No Violations | I was on location to assess compliance notice # -832977104. I found the pressure on the injection tubing reduced below the maximum allowable pressure. |
1566219903 | 2019-8-19 0:00: | SW | No Violations | 0.70 |
1579588905 | 2020-1-27 0:00: | SW | No Violations | 0.90 |
1659293777 | 2018-05-02 | Salt Water Injection Well | No Violations | I was on location for an UIC facility inspection. The injection well was not in operation on the day of my inspection. The gate valve on the tubing was closed. A facility operator was on location. I observed no leaks or spills. Identification signs are posted. There are no violations at this time. |
1771513049 | 2014-12-11 | Salt Water Injection Well | No Violations | The well was treated with acid the previous day. The tubing/casing annulus was pressured up to 504 psi., using fresh water. The purpose of this inspection was to follow-up and check the well pressures. A pump truck remains on location. The acid treatment will be displaced further, after a wait period. |
1795280052 | 2013-04-02 | Drill / Deepen / Reopen | No Violations | I witnessed Universal Well Service cement the surface casing for Pander Trucking. Wildcat drilled Hole #2 to a depth of 355 and set the 11.75 intermediated casing to 343. Universal broke circulation and pumped 250 sacks of cement. They displaced with 39 barrels of fresh water. I witnessed 24 barrels of good cement returns to surface. |
1803176271 | 2013-03-26 | Drill / Deepen / Reopen | No Violations | I inspected the well site and found no violations. The construction contractor was working on the well site, while drilling equipment was moving on location. |
1938703032 | 2014-11-13 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. There were no violations found at the time. |
1940790630 | 2020-8-18 0:00: | SW | No Violations | 0.40 |
198676896 | 2014-7-29 0:00: | SW | No Violations | |
1999418120 | 2014-04-03 | Salt Water Injection Well | No Violations | An inspection found the well shut-in. Preliminary restoration will need to be completed, once weather permits. There were no violations at this time. |
2024434554 | 2013-08-28 | Salt Water Injection Well | No Violations | The well has yet to be connected to injection facility. My inspection found the preliminary restoration incomplete. The topsoil needs graded and seeded. |
2031012139 | 2019-5-14 0:00: | SW | No Violations | 0.40 |
246122492 | 2015-3-17 0:00: | SW | No Violations | |
250262502 | 2013-10-23 0:00 | SW | No Violations | |
435602057 | 2017-9-20 0:00: | SW | No Violations | 0.30 |
548562466 | 2016-7-21 0:00: | SW | No Violations | |
552782669 | 2013-3-27 0:00: | DD | No Violations | 0.50 |
578767101 | 2016-9-12 0:00: | SW | No Violations | |
598910368 | 2018-3-22 0:00: | SW | No Violations | 0.30 |
702116830 | 2016-3-31 0:00: | SW | No Violations | |
721069155 | 2014-4-21 0:00: | SW | No Violations | |
737024660 | 2016-5-17 0:00: | SW | No Violations | 0.50 |
740456744 | 2020-4-6 0:00:0 | SW | No Violations | 0.40 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0198676896 | US-OH-120119 | 2014-10-06 | Violation of injection tubing/fitting requirements | |
0832977104 | US-OH-129491 | 2018-10-03 | 9-3-07(D) | Exceeding maximum allowable injection pressure |
For data sources see[4]