Well Details

Well ID: 34-155-23794
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Newton Township
Operator Name: HECKMANN WATER RESOURCES (CVR)
Well Pad ID:
Farm/Lease Name: PANDER R & P (SWIW #16)
License Status: Active Injection
License Date: 2013-01-31
Spud Date: 2013-03-27
Spud Drilling Contractor: WILDCAT DRILLING
Final Drill Date: 2013-04-07
Well Total Depth: 4183.00 ft
Configuration: Vertical
Latitude: 41.190000
Longitude: -80.990000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-10-26 Proposed Formations:NEWBURG, Issued Date:10/26/2005, Expired Date:10/26/2006 6:00:00 AM, Drilling unit acres:7.955, Proposed Well Type:SWD, Proposed Well Class:SWIW
APP 2013-01-31 Proposed Formations:NEWBURG, Issued Date:1/31/2013, Expired Date:1/31/2015 12:00:00 PM, Drilling unit acres:7.955, Proposed Well Type:SWD, Proposed Well Class:SWIW
Reached Total Depth 2013-04-07
Annulus Pressure Monitoring Approved 2013-04-08
Last Compliance Report 2013-04-26
Change of Owner 2013-07-23 Operator changed from 1258, PANDER RAY TRUCKING INC to 8981, HECKMAN WATER RES(CVR)INC. O&G
Construction Permit Expires 2015-01-31
Completion Report Received 2018-06-01
Record Last Modified 2018-06-04

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2013-10-14 H2O 0 198869 Gal 0 Universal Well Services Inc.

For data sources see[3]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1015760095 2018-11-8 0:00: SW No Violations 0.30
-1016255905 2013-4-2 0:00:0 DD No Violations 5.00
-1036683364 2013-1-7 0:00:0 SW No Violations
-105194851 2015-12-22 0:00 SW No Violations 0.30
-1156172208 2017-4-19 0:00: SW No Violations
-1318293731 2017-1-26 0:00: SW No Violations
-178752135 2017-5-22 0:00: SW No Violations
-1803176271 2013-3-26 0:00: DD No Violations
-1938703032 2014-11-13 0:00 SW No Violations
-1964150001 2019-6-10 0:00: SW No Violations 0.30
-1999418120 2014-4-3 0:00:0 SW No Violations
-3158804 2019-11-21 0:00 SW No Violations 1.20
-333795539 2014-9-10 0:00: SW No Violations
-376219122 2017-12-4 0:00: SW No Violations 0.30
-430207196 2015-6-3 0:00:0 SW No Violations
-832977104 2018-8-6 0:00:0 SW No Violations 0.60
-993298970 2015-6-16 0:00: SW No Violations
0105194851 2015-12-22 Salt Water Injection Well No Violations I was on location to inspect the injection well and facility. The tank battery is in good repair. There is no free oil or water in the dike. The well was not in operations at the time of my inspection. The pump room was in good repair. The well operator was on location. There are no violations at this time.
0140489283 2013-12-03 Salt Water Injection Well No Violations The well was shut-in, because the maximum injection pressure was reached. There were no violations at the time of inspection.
0149566577 2016-12-22 Salt Water Injection Well No Violations The injection well and surface facility were inspected. The well was found shut-in at the time.

No violations were found.

0178752135 2017-05-22 Salt Water Injection Well No Violations The injection well and surface facility were inspected. The pump was operating. There were no violations found at the time.
0198676896 2014-07-29 Salt Water Injection Well Violations Noted An inspection found the injection well was not equipped with a 1/4 inch fitting on the tubing/casing annulus. Allen Goodrich was instructed to install a 1/4 inch valve on the casing.
0246122492 2015-03-17 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations found at the time.
0250262502 2013-10-23 Salt Water Injection Well No Violations A mechanical integrity test was performed on the flow line. A pressure of 1120 psi. was held on the flow line for fifteen minutes. The test passed.
0333795539 2014-09-10 Salt Water Injection Well No Violations There were no violations at the time of inspection. A company representative was instructed to put a minimum pressure of 200 psi. on the tubing/casing annulus.
0376219122 2017-12-04 Salt Water Injection Well No Violations I was on location to inspection the injection well. The facility is in good repair. An identification sign is posted. There was an HWR brine truck on location with the proper UIC number (#407) displayed. There are no violations at this time.
0430207196 2015-06-03 Salt Water Injection Well No Violations The well and surface facility were inspected. The well was found shut-in. There were no violations found at the time of inspection.
0435602057 2017-09-20 Salt Water Injection Well No Violations I was on location to inspect the injection well. The facility is in good repair. I observed no visible leaks. There is a locked gate at the access road entrance. An identification sign is posted. There are no violations at this time
0548562466 2016-07-21 Salt Water Injection Well No Violations The injection well was found shut-in. There were no violations found at the time.
0552782669 2013-03-27 Drill / Deepen / Reopen No Violations My inspection found the drilling depth at 82; no violations.
0578767101 2016-09-12 Salt Water Injection Well No Violations The injection well and surface facility were inspected. The well was shut-in. There were no violations found at the time.
0598910368 2018-03-22 Salt Water Injection Well No Violations I was on location to inspect the injection well and facility. I found the injection shut-
0702116830 2016-03-31 Salt Water Injection Well No Violations The injection well and surface facility were inspected. The well was found shut-in. There were no violations found at the time.
0721069155 2014-04-21 Salt Water Injection Well No Violations The well was found shut-in. The well site was graded.
0737024660 2016-05-17 Salt Water Injection Well No Violations


The equipment on the site consists of the following:


3 Frac tanks 1 Injection well

0832977104 2018-08-06 Salt Water Injection Well Violations Noted I found the injection well not operating on the day of my inspection. I obtained a pressure reading on the injection tubing of 970 psi, which is 50 psi over the maximum allowable pressure. The gate valve on the tubing is in the open position. An identification sign is posted. I observed no leaks or spills. I spoke with Alan Goodrich from NWR. I told Mr. Goodrich a compliance notice would be issued and to address the issue immediately. Mr. Goodrich stated the well would be shut-in and correct the issue. A follow-up inspection will be conducted by 8/7/2018.
0993298970 2015-06-16 Salt Water Injection Well No Violations The well and surface facility were inspected. There were no violations found at the time of inspection.
1015760095 2018-11-08 Salt Water Injection Well No Violations I found the injection not in operation on the day of my inspection. Identification signs are posted. I observed no spills or leaks.
1016255905 2013-04-02 Drill / Deepen / Reopen No Violations I witnessed Universal Well Service cement the conductor casing for Pander Trucking. Wildcat Rig drilled a 22 hole to 94 and set the 16 conductor casing at 86. Universal broke circulation and pumped 380 sacks of cement. They displaced with 16 barrels of fresh water. I did not witness any cement returns to surface. Universal placed 25 bags of cement down the annulus. The cement was tagged more than 15 down the hole. Pander Trucking ordered 8 yards of cement, which was placed down the annulus. Cement was tagged at the surface.
1036683364 2013-01-07 Salt Water Injection Well No Violations The well owner applied for a reissued permit. I inspected the site as part of the pre-permit review.
1051228135 2007-11-14 Salt Water Injection Well No Violations Pre-site inspection . There no water wells or body of water within 500 .
1067532019 2019-01-16 Salt Water Injection Well No Violations I found the injection well not operating on the day of my inspection. An identification sign is posted at the injection well. I observed no leaks or spills. I received a call from Alan Goodrich from HWR. Mr. Goodrich stated the identification sign for the injection well has been made and will be posted this week.
1117385760 2013-04-01 Drill / Deepen / Reopen No Violations The blow-out preventor was tested with 500 psi. of pressure. There was a loss of 20 psi., during 20 minutes. The loss was attributed to a valve on the test line. The test passed.
1156172208 2017-04-19 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations found at the time.
1318293731 2017-01-26 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations at the time.
1365426984 2013-04-08 Drill / Deepen / Reopen No Violations My inspection found Wildcat rigging down; no violations.
1388332988 2018-01-18 Salt Water Injection Well No Violations I found the injection and facility in good repair on the day of my inspection. I observed no leaks or spills. An identification sign is posted. There are no violations at this time.
1394646588 2019-4-9 0:00:0 SW No Violations 0.30
1396626386 2014-03-20 Salt Water Injection Well No Violations The well was shut-in. Preliminary restoration will be required when weather permits.
140489283 2013-12-3 0:00: SW No Violations
1418319672 2014-12-10 Salt Water Injection Well No Violations A contractor, Producers Service Corporation, was treating the well with acid. The tubing/casing annulus was pressured up to 504 psi.
149566577 2016-12-22 0:00 SW No Violations
1513076856 2013-04-08 Salt Water Injection Well No Violations A Weatherford AS1X packer was set in compression on 5-1/2 inch casing. A mechanical integrity test was performed on the well. A pressure of 1035 psi. was placed on the 5-1/2 inch and 8-5/8 inch casing annulus. The pressure held without loss for a 15 minute test period.
1533661433 2018-08-07 Salt Water Injection Well No Violations I was on location to assess compliance notice # -832977104. I found the pressure on the injection tubing reduced below the maximum allowable pressure.
1566219903 2019-8-19 0:00: SW No Violations 0.70
1579588905 2020-1-27 0:00: SW No Violations 0.90
1659293777 2018-05-02 Salt Water Injection Well No Violations I was on location for an UIC facility inspection. The injection well was not in operation on the day of my inspection. The gate valve on the tubing was closed. A facility operator was on location. I observed no leaks or spills. Identification signs are posted. There are no violations at this time.
1771513049 2014-12-11 Salt Water Injection Well No Violations The well was treated with acid the previous day. The tubing/casing annulus was pressured up to 504 psi., using fresh water. The purpose of this inspection was to follow-up and check the well pressures. A pump truck remains on location. The acid treatment will be displaced further, after a wait period.
1795280052 2013-04-02 Drill / Deepen / Reopen No Violations I witnessed Universal Well Service cement the surface casing for Pander Trucking. Wildcat drilled Hole #2 to a depth of 355 and set the 11.75 intermediated casing to 343. Universal broke circulation and pumped 250 sacks of cement. They displaced with 39 barrels of fresh water. I witnessed 24 barrels of good cement returns to surface.
1803176271 2013-03-26 Drill / Deepen / Reopen No Violations I inspected the well site and found no violations. The construction contractor was working on the well site, while drilling equipment was moving on location.
1938703032 2014-11-13 Salt Water Injection Well No Violations The injection well and surface facility were inspected. There were no violations found at the time.
1940790630 2020-8-18 0:00: SW No Violations 0.40
198676896 2014-7-29 0:00: SW No Violations
1999418120 2014-04-03 Salt Water Injection Well No Violations An inspection found the well shut-in. Preliminary restoration will need to be completed, once weather permits. There were no violations at this time.
2024434554 2013-08-28 Salt Water Injection Well No Violations The well has yet to be connected to injection facility. My inspection found the preliminary restoration incomplete. The topsoil needs graded and seeded.
2031012139 2019-5-14 0:00: SW No Violations 0.40
246122492 2015-3-17 0:00: SW No Violations
250262502 2013-10-23 0:00 SW No Violations
435602057 2017-9-20 0:00: SW No Violations 0.30
548562466 2016-7-21 0:00: SW No Violations
552782669 2013-3-27 0:00: DD No Violations 0.50
578767101 2016-9-12 0:00: SW No Violations
598910368 2018-3-22 0:00: SW No Violations 0.30
702116830 2016-3-31 0:00: SW No Violations
721069155 2014-4-21 0:00: SW No Violations
737024660 2016-5-17 0:00: SW No Violations 0.50
740456744 2020-4-6 0:00:0 SW No Violations 0.40

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0198676896 US-OH-120119 2014-10-06 Violation of injection tubing/fitting requirements
0832977104 US-OH-129491 2018-10-03 9-3-07(D) Exceeding maximum allowable injection pressure

For data sources see[4]