X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-155-23914

Well Details

Well ID: 34-155-23914
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Hartford Township
Operator Name: COBRA RESOURCES LLC
Well Pad ID:
Farm/Lease Name: STUARD
License Status: Producing
License Date: 2008-04-22
Spud Date: 2008-09-25
Spud Drilling Contractor: KILBARGER DRLG
Final Drill Date: 2008-09-30
Well Total Depth: 4883.00 ft
Configuration: Vertical
Latitude: 41.330000
Longitude: -80.540000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-04-22 Proposed Formations:CLINTON/MEDINA, Issued Date:4/22/2008, Expired Date:4/22/2009 6:00:00 AM, Drilling unit acres:94.23, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-09-30
Completion Report Received 2009-01-22
Construction Permit Expires 2009-04-22
Change of Owner 2012-04-12 Operator changed from 8280, COBRA RESOURCES LLC to 8956, STRYKER ENERGY LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-03-10 4650 4728 38
4650 4728 38
4650 4728 38

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 75992 Gal 70000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 COBRA RESOURCES LLC 0.00 0.00 0
2009 COBRA RESOURCES LLC 0.00 0.00 0
2010 COBRA RESOURCES LLC 271.00 0.00 250
2011 STRYKER ENERGY LLC 396.00 83.00 280
2012 STRYKER ENERGY LLC 78.00 0.00 84
2013 STRYKER ENERGY LLC 0.00 0.00 0
2014 STRYKER ENERGY LLC 0.00 0.00 0
2015 STRYKER ENERGY LLC 0.00 0.00 0
2016 STRYKER ENERGY LLC 0.00 0.00 0
2017 STRYKER ENERGY LLC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 COBRA RESOURCES LLC Brine 0 0
2009 COBRA RESOURCES LLC Brine 0 0
2010 COBRA RESOURCES LLC Brine 1328 250
2011 STRYKER ENERGY LLC Brine 1190 280
2012 STRYKER ENERGY LLC Brine 0 84
2013 STRYKER ENERGY LLC Brine 0 0
2014 STRYKER ENERGY LLC Brine 0 0
2015 STRYKER ENERGY LLC Brine 0 0
2016 STRYKER ENERGY LLC Brine 0 0
2017 STRYKER ENERGY LLC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1268132571 2018-8-14 0:00: PW No Violations 0.80
-1548429788 2019-1-31 0:00: PW No Violations 0.80
-1846518428 2010-6-29 0:00: PL No Violations
-1902728926 2018-1-11 0:00: PW No Violations
-1973463161 2020-6-1 0:00:0 PW No Violations
-332010116 2014-8-1 0:00:0 PW No Violations 0.50
0332010116 2014-08-01 Production Wells No Violations I was on location for a status check inspection. I found the well not in production. The well was equipment with a pumping unit. Two, ball valves on the flow line off of the tubing were closed. The tank battery consisted of two, 100 barrel production tanks, two, 50 barrel poly brine tanks and two separators. A dike surrounded the production equipment. An identification sign was posted. A plug was installed on the load line. The lease road was in stable condition. The tank battery was shared with permit number 2-3934.
1048414908 2019-03-25 Production Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice # 1268132571 and complaint #5923, regarding installation of identification and plugging the well. At the time of this inspection, the well did not have identification installed and the well has not been plugged. There has not been a plugging permit obtained from Styker Energy, at the time of this inspection. I attempted to contact Stryker Energy, LLC by calling multiple phone numbers associated with this company and all of the phone numbers have been disconnected. I was unable to connect with this company to address the open compliance issues.
1268132571 2018-08-14 Production Wells Violations Noted Follow-up to Non-Producing Well Complaint #5923. I spoke with the attorney for the landowner Michael Grove on 8/8/18 and told him I would inspect the wells the week of 8/13/18. My inspection today found this well equipped with 1.5 tubing and rods and a natural gas powered pumping unit. There is currently no motor to operate the pumping unit and there is a 30 barrel tank plumbed in in front of the wellhead. Small trees and tall weeds have engulfed the pumping unit to the point where it cannot be thoroughly inspected. The tubing and 4.5 production casing flow line valves are closed and the well is shut-in and not capable of production in its current state. This well produced to a diked tank battery to the west and is shared with the Stuard Unit 1 (PN#23934). The battery contains two (2) 100 barrel tanks, two (2) 50 barrel poly tanks, and two (2) horizontal separators and each well produces through a dedicated set of equipment. The poly tank for this well currently contains 40+ barrels fluid. The inlet and outlet valves on the separator are closed and the well is not in production. There is a domestic tap on the separator sales line and the supply valve is closed. The required identification is posted at the tank battery, but is not posted at the wellhead in violation of ORC 1501:9-9-05(A)10. Production records indicate that Stryker Energy, LLC produced the well for 84 days during the 2012 reporting period and produced 78 Mcf of natural gas, zero (0) barrels of oil, and zero (0) barrels of brine. The well has produced zero (0) Mcf of natural gas, zero (0) barrels of oil, and zero (0) barrels of brine for the last five (5) reporting periods, has not been placed in Temporary Inactive Status, and has not been approved for another activity by the Chief. This well is in violation of 1509.062(A) of the Ohio Revised Code and it is determined that the well is currently incapable of production. The well owner/operator shall submit a written plugging schedule to M
1548429788 2019-01-31 Production Wells No Violations I conducted a compliance notice follow-up inspection for compliance notice 1268132571 and complaint #5923, regarding installation of identification and plugging the well. At the time of this inspection, the well was equipped with a pumping unit and not in production. No identification has been installed at the well location and the well has not been plugged. There was a 30 barrel tank plumbed in front of the wellhead. Vegetative maintenance had not been conducted at the well location. The inlet and outlet valves on the separator were closed as well as the valve on the domestic line off the separator. The sales line and the supply valve was also closed at the tank battery location. Identification was posted at the tank battery, but still needs installed at the well location, due to a shared tank battery with well 2-3934.
1558371461 2019-5-20 0:00: PW No Violations
1585077806 2020-3-18 0:00: PW No Violations
1615864495 2020-9-3 0:00:0 PW No Violations
1669079672 2019-9-18 0:00: PW No Violations
1846518428 2010-06-29 Preliminary Restoration No Violations no violations .
1902728926 2018-01-11 Production Wells No Violations I conducted chiefs order follow-up inspection on this well, regarding liability insurance. The well was equipped with a pumpjack and the valves on the annulus and flow line were closed. The tank battery consisted of two 100 BBL production tanks, two 50 BBL poly brine tanks and two mechanical separators. Valves on the separators were closed. There was a domestic line at the tank battery with a meter, drip bottle and regulator. The valve on the 1 inch line was open. The tank battery was diked and is shared with well 2-3934. There was legible signage located at the tank battery but needed added at the well due to a shared tank battery. The lease acess was stable. I called Stryker Energy and spoke with manager Gary Regan. He indicated that the insurance had been sent in to DOGRM, Columbus office and was being processed.
450181430 2020-7-14 0:00: PW No Violations
524218447 2019-8-1 0:00:0 PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1268132571 US-OH-107195 2018-09-04 Failure to legibly identify well
1268132571 US-OH-107196 2018-09-04 Well shall be plugged

For data sources see[9]

References