Well ID: 34-155-23940 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.14,"lon":-80.67,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Trumbull | |
Municipality: Liberty Township | |
Operator Name: AM-TEK OIL INC | |
Well Pad ID: | |
Farm/Lease Name: BELMONT PARK CEMETERY UNIT | |
License Status: Producing | |
License Date: 2008-06-11 | |
Spud Date: 2008-09-10 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2008-09-16 | |
Well Total Depth: 5224.00 ft | |
Configuration: Vertical | |
Latitude: 41.140000 | |
Longitude: -80.670000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2008-06-11 | Proposed Formations:ORISKANY/CLINTON/QUEENSTON, Issued Date:6/11/2008, Expired Date:6/11/2009 6:00:00 AM, Drilling unit acres:176.99, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2008-09-16 | |
Completion Report Received | 2008-10-14 | |
Construction Permit Expires | 2009-06-11 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2008-11-25 | 5027 | 5148 | 77 |
5027 | 5148 | 77 | |
5027 | 5148 | 77 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 0 | 0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | DUCK CREEK ENERGY INC | 0.00 | 0.00 | 24 |
2009 | DUCK CREEK ENERGY INC | 12172.00 | 758.00 | 365 |
2010 | DUCK CREEK ENERGY INC | 11839.00 | 593.00 | 365 |
2011 | DUCK CREEK ENERGY INC | 9929.00 | 441.00 | 365 |
2012 | DUCK CREEK ENERGY INC | 7918.00 | 321.00 | 366 |
2013 | DUCK CREEK ENERGY INC | 6465.00 | 383.00 | 365 |
2014 | DUCK CREEK ENERGY INC | 6055.00 | 342.00 | 365 |
2015 | DUCK CREEK ENERGY INC | 5806.00 | 297.00 | 365 |
2016 | DUCK CREEK ENERGY INC | 5738.00 | 351.00 | 365 |
2017 | DUCK CREEK ENERGY INC | 5439.00 | 247.00 | 365 |
2018 | DUCK CREEK ENERGY INC | 5217.00 | 265.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | DUCK CREEK ENERGY INC | Brine | 290 | 24 |
2009 | DUCK CREEK ENERGY INC | Brine | 638 | 365 |
2010 | DUCK CREEK ENERGY INC | Brine | 290 | 365 |
2011 | DUCK CREEK ENERGY INC | Brine | 182 | 365 |
2012 | DUCK CREEK ENERGY INC | Brine | 25 | 366 |
2013 | DUCK CREEK ENERGY INC | Brine | 0 | 365 |
2014 | DUCK CREEK ENERGY INC | Brine | 55 | 365 |
2015 | DUCK CREEK ENERGY INC | Brine | 53 | 365 |
2016 | DUCK CREEK ENERGY INC | Brine | 25 | 365 |
2017 | DUCK CREEK ENERGY INC | Brine | 0 | 365 |
2018 | DUCK CREEK ENERGY INC | Brine | 50 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1324666170 | 2011-9-9 0:00:0 | PL | No Violations | |
-60714443 | 2012-12-4 0:00: | UP | No Violations | 0.50 |
0060714443 | 2012-12-04 | UrbanProduction Wells | No Violations | I completed an urban production well inspection. My inspection found the well equipped with a plunger lift unit that was surround by a chain link fence. The tank battery was surrounded by a chain link fence with an identification sign, a dike, and contained two, 100 barrel oil storage tank, one, 50 barrel brine storage tank, and two separators. The lease road was part of the cemetery road. I noticed no visible spills or leaks. The well had the proper HB-278 equipment installed at the tank battery. |
1324666170 | 2011-09-09 | Preliminary Restoration | No Violations | Preliminary Restoration was completed and meets all requirements. |
1622525073 | 2015-05-11 | UrbanProduction Wells | No Violations | I was on location for a status check. During my inspection, I found the well in production. The well is equipped with a plunger lift assembly. The tank battery consists of two, 100 barrel production tanks and two, mechanical separators. A dike surrounds the tank battery. Identification signs were posted. Locked, chain link fences with barb wire surround the well and tank battery. Proper urban, safety equipment has been installed. The lease road is in stable condition. |
For data sources see[9]