34-099-20833

Well Details

Well ID: 34-099-20833
Loading map...
Country: United States
State: Ohio
County: Mahoning
Municipality: Ellsworth Township
Operator Name: D & L ENERGY INC
Well Pad ID:
Farm/Lease Name: WILSON
License Status: Final Restoration
License Date: 2016-01-08
Spud Date: 1977-02-26
Spud Drilling Contractor: PERKINS DRLG
Final Drill Date: 1977-03-03
Well Total Depth: 5365.00 ft
Configuration: Vertical
Latitude: 41.010000
Longitude: -80.900000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1976-10-19 504 UNITED PETROLEUM CORP GeoDate 10/19/76
Original Spud 1977-02-26 WELL DRILLED..NO COMPLETION/PRODUCTION DATA REPORTED R.L. 12-15-76
Completed 1977-03-03 WELL DRILLED..NO COMPLETION/PRODUCTION DATA REPORTED R.L. 12-15-76
Reached Total Depth 1977-03-03 WELL DRILLED..NO COMPLETION/PRODUCTION DATA REPORTED R.L. 12-15-76
Completion Report Received 1978-03-20 WELL DRILLED..NO COMPLETION/PRODUCTION DATA REPORTED R.L. 12-15-76
Change of Owner 2003-01-13 Operator changed from 504, UNITED PETROLEUM CORP to 2651, D & L ENERGY INC
APP 2016-01-08 Proposed Formations:QUEENSTON, Issued Date:1/8/2016, Expired Date:1/7/2018 12:00:00 PM, Drilling unit acres:133, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2016-02-29 WELL DRILLED..NO COMPLETION/PRODUCTION DATA REPORTED R.L. 12-15-76
Record Last Modified 2017-02-15 WELL DRILLED..NO COMPLETION/PRODUCTION DATA REPORTED R.L. 12-15-76
Construction Permit Expires 2018-01-07 WELL DRILLED..NO COMPLETION/PRODUCTION DATA REPORTED R.L. 12-15-76

For data sources see[2]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2011 D & L ENERGY INC 0.00 0.00 0
2014 D & L ENERGY INC 0.00 0.00 0
2016 D & L ENERGY INC 0.00 0.00 0

For data sources see[3] [4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2011 D & L ENERGY INC Brine 0
2014 D & L ENERGY INC Brine 0 0
2016 D & L ENERGY INC Brine 0 0

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1401132668 2016-8-30 0:00: FR No Violations 1.00
-903846215 2015-3-16 0:00: PW No Violations 0.50
0257097051 2016-02-18 Plug / Plug Back No Violations I was on location to witness the digging of the pit to be used while drilling with the power swivel. The pit was lined with a 30 mil liner. There was 70 barrels of salt brine put in the pit to be used as drilling fluid. They started drilling with a 3.5 tri-cone bit and using 2 3/8 up-set tubing and broke through at 450. After running and drilling 120 they laid down there power swivel so they could make better time after several blockages they rigged up there power swivel shut down for the day.
0284576512 2016-02-19 Plug / Plug Back No Violations Moores Well Service is drilling and hitting blockages at various depth, finishes the day at 1360
0333715027 2015-03-16 Production Wells No Violations FOLLOW UP TO NOV # -903846215 I was on location for a status check. During my inspection, I found the well incapable of production. The wells 4.5 inch casing protruded approximately 8 inches above ground with no plug or cap. The well is marked with an orange safety barrel. There is no identification posted. There is no production equipment associated with the well. A compliance notice will be issued to plug the well and failure to properly identify. The only annual production filed by D & L was zero in 2011. A proper identification sign will be posted by 6/1/2015. Photos were taken and are available upon request.
0903846215 2015-03-16 Production Wells Violations Noted I was on location for a status check. During my inspection, I found the well incapable of production. The wells 4.5 inch casing protruded approximately 8 inches above ground with no plug or cap. The well is marked with an orange safety barrel. There is no identification posted. There is no production equipment associated with the well. A compliance notice will be issued to plug the well and failure to properly identify. The only annual production filed by D & L was zero in 2011. A proper identification sign will be posted by 6/1/2015. Photos were taken and are available upon request.
1401132668 2016-08-30 Final Restoration No Violations I performed a final restoration inspection on the above location. There was no production equipment or pipeline installed. The area that was used to enter into the location and the location of the well has been restored and vegetation has been established. Final Restoration is passed.
1457362178 2016-02-17 Plug / Plug Back No Violations Moores Well Service rigged up their wire line and their casing ripping tool to check total depth ( TD ). TD should be at 5341. As they run in with a wire line they sat down at 450 after various attempts they could not go any deeper. Thy pulled out of the 4.5 casing and picked up a 3.5 tri-cone bit and 2 3/8 tubing and ran back in the casing and attempted to rotate the bit with there power tongs they were unable to go deeper. After pulling out the bit they discovered that the was wood and metal on the bit. The decision was made to bring there power swivel and mud pump and drill.
1463752994 2016-02-24 Plug / Plug Back No Violations Moore Well Service is drilling and attempting to get to the TD of the well which is 5334. They have encountered obstructions at different depths. At this time we are at 5210. Only made 6 of depth in 3 hours. I called Deputy Director Dave Claus and Northeast Regional Supervisor Tom Hill and ask if we could set a 300 bottom plug at this depth. They both agreed on the placement of the bottom plug. Shut down for the day.
1463756333 2016-02-25 Plug / Plug Back No Violations I was on location to witness the setting of the 300 bottom plug. After calling Pertoset they informed Keith Moore that it would be later in the day before they could get there. The trucks were in PA plugging and had trouble. Keith Moore called me at 7:00 pm and informed me that the plug was pumped and displaced through 2-3/8 tubing. I informed him that we would need to tag the plug the next day before ripping the pipe.
1463758061 2016-02-26 Plug / Plug Back No Violations Pulled 2-3/8 tubing in and tagged bottom plug at 4806. Ripped 4.5 casing at 3630 shut down for the day.
1467731940 2016-03-01 Plug / Plug Back No Violations I was on location to witness the plugging of this well. Moore Well Service and Petroset Cementing were the contractors on location performing the plugging operations. There was a Compliance Notice (-903846215) issued on 3/24/2015. This notice can be closed at this time.
1802926250 2016-03-01 Plug / Plug Back No Violations I performed an inspection on the above plugged well. The top of the cement was at 5. They well be cutting it 4 below ground level and will weld a ID plate on the 8-5/8 casing.. Plug job completed.
257097051 2016-2-18 0:00: PB No Violations 8.00
284576512 2016-2-19 0:00: PB No Violations 6.00
333715027 2015-3-16 0:00: PW No Violations 0.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0903846215 US-OH-130318 2015-05-04 Failure to legibly identify well
0903846215 US-OH-130319 2015-05-04 Well shall be plugged
0903846215 US-OH-130320 2016-07-26 NONEC Statement of annual production not filed

For data sources see[7]

References