Well ID: 34-099-22304 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.02,"lon":-80.78,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Mahoning | |
Municipality: Canfield Township | |
Operator Name: EVERFLOW EASTERN PARTNERS LP | |
Well Pad ID: | |
Farm/Lease Name: CANFIELD STANDARD SLAG UNIT | |
License Status: Producing | |
License Date: 1989-01-11 | |
Spud Date: 1989-01-20 | |
Spud Drilling Contractor: [[JL COATS [COATS-GOFF]]] | |
Final Drill Date: 1989-01-30 | |
Well Total Depth: 5500.00 ft | |
Configuration: Vertical | |
Latitude: 41.020000 | |
Longitude: -80.780000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Oil and Gas | 1989-01-11 | Issued Date 1/11/89 Expired Date 1/11/90 Acres 0040000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 05500 Proposed Drill Depth 05500 |
Original Spud | 1989-01-20 | |
Completed | 1989-01-30 | |
Reached Total Depth | 1989-01-30 | |
CO | 1989-02-13 | 84 EVERFLOW EASTERN PTNS L P GeoDate 1/11/89 |
Completion Report Received | 1989-02-24 | |
Construction Permit Expires | 1990-01-11 | |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 5332 | 5432 | 37 |
5332 | 5432 | 37 | |
5332 | 5432 | 37 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 122000 Gal | 80000 | FRAC:WATER/SAND |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1920382945 | 2005-2-4 0:00:0 | PW | No Violations | 0.50 |
000PL12523 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0565506335 | 2007-12-27 | Production Wells | No Violations | I performed a random field inspection. GPSd both the tank battery and the wellhead. The ID sign was posted. The tank battery was in good shape. I found no violations at this time. |
0722169193 | 2018-03-20 | Production Wells | No Violations | The purpose of my inspection was to conduct a status check on well #2-2304. RBDMS indicated reported production was current. The well was located in a residential development. Adequate landscaping was present around the well head. The well was located within a locked chain link fence enclosure. Correct identification was present on the fence. The 8.625 well head was plumbed above grade and closed to atmosphere. The 4.5 production casing was equipped with a plunger lift assembly. Production valves were in the open position. A domestic supply connection was present. No leaks were observed. The tank battery was shared with well #2-2298. A locked chain link fence enclosure with correct identification for both wells was present around the facility. A stable earthen dike that was free of fluid was present around the production equipment. Equipment within the dike consisted of two (2) horizontal separators and one (1) steel production tank. The separator for well #2-2304 remained in good repair and contained a current 7 day production chart. The production tank remained in good repair. Valves were closed and lugged. The hatch lid was closed and locked. No violations were observed during this inspection. |
1007882258 | 2018-12-26 | Production Wells | No Violations | I performed a status check on the above location. The well is equipped with 1.5 tubing. The tank battery is equipped with one horizonal separator and a 100 barrel tank. Valves are shut and plugged. ID signs are posted. No noted violations at this time |
1920382945 | 2005-02-04 | Production Wells | No Violations | The tank battery is shared with permit 2298 and consists of 1-100 bbl storage tank, 2-separators a dike and a fence. |
565506335 | 2007-12-27 0:00 | PW | No Violations | |
722169193 | 2018-3-20 0:00: | PW | No Violations | 0.40 |
PL12523 | PL | No Violations |
For data sources see[9]