X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-099-22344

Well Details

Well ID: 34-099-22344
Loading map...
Country: United States
State: Ohio
County: Mahoning
Municipality: Canfield Township
Operator Name: EVERFLOW EASTERN PARTNERS LP
Well Pad ID:
Farm/Lease Name: NAFFAH UNIT
License Status: Producing
License Date: 1989-08-11
Spud Date: 1989-10-22
Spud Drilling Contractor: [[JL COATS [COATS-GOFF]]]
Final Drill Date: 1989-10-19
Well Total Depth: 5623.00 ft
Configuration: Vertical
Latitude: 41.020000
Longitude: -80.730000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1989-08-11 1736 WRP ENERGY INC GeoDate 8/11/89
Oil and Gas 1989-08-11 Issued Date 8/11/89 Expired Date 8/11/90 Acres 0059305 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 05623 Proposed Drill Depth 05623
Original Spud 1989-10-12
Completed 1989-10-19
Reached Total Depth 1989-10-19
Completion Report Received 1990-05-09
Construction Permit Expires 1990-08-11
CO 1993-02-05 84 EVERFLOW EASTERN PTNS L P GeoDate 8/11/89
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 5392 5494 0
5392 5494 0
2006-09-11 5438 5490 19
5438 5490 19
5392 5494 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 103 Gal 60000 20/40 SAND, 35 BPM
ACID 0 500 Gal 0 FRAC:WATER/SAND
N2 0 200 Mscf 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1990 WRP ENERGY INC 30706.00 0.00 365
1991 WRP ENERGY INC 23316.00 0.00 365
1992 WRP ENERGY INC 20218.00 0.00 365
1993 EVERFLOW EASTERN PARTNERS LP 0.00 0.00 365
1994 EVERFLOW EASTERN PARTNERS LP 12590.00 0.00 353
1995 EVERFLOW EASTERN PARTNERS LP 10704.00 0.00 365
1996 EVERFLOW EASTERN PARTNERS LP 9533.00 0.00 365
1997 EVERFLOW EASTERN PARTNERS LP 7892.00 0.00 365
1998 EVERFLOW EASTERN PARTNERS LP 9555.00 0.00 365
1999 EVERFLOW EASTERN PARTNERS LP 8923.00 0.00 365
2000 EVERFLOW EASTERN PARTNERS LP 7852.00 0.00 365
2001 EVERFLOW EASTERN PARTNERS LP 4604.00 0.00 365
2002 EVERFLOW EASTERN PARTNERS LP 4342.00 0.00 365
2003 EVERFLOW EASTERN PARTNERS LP 6713.00 0.00 365
2004 EVERFLOW EASTERN PARTNERS LP 5965.00 0.00 365
2005 EVERFLOW EASTERN PARTNERS LP 3772.00 0.00 365
2006 EVERFLOW EASTERN PARTNERS LP 1902.00 0.00 365
2007 EVERFLOW EASTERN PARTNERS LP 2832.00 0.00 365
2008 EVERFLOW EASTERN PARTNERS LP 3091.00 0.00 365
2009 EVERFLOW EASTERN PARTNERS LP 1394.00 0.00 365
2010 EVERFLOW EASTERN PARTNERS LP 3110.00 0.00 365
2011 EVERFLOW EASTERN PARTNERS LP 1541.00 0.00 197
2012 EVERFLOW EASTERN PARTNERS LP 712.00 0.00 156
2013 EVERFLOW EASTERN PARTNERS LP 9152.00 0.00 365
2014 EVERFLOW EASTERN PARTNERS LP 8262.00 64.00 335
2015 EVERFLOW EASTERN PARTNERS LP 5602.00 0.00 365
2016 EVERFLOW EASTERN PARTNERS LP 46.00 0.00 365
2017 EVERFLOW EASTERN PARTNERS LP 7525.00 0.00 365
2018 EVERFLOW EASTERN PARTNERS LP 4298.00 14.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1990 WRP ENERGY INC Brine 107 365
1991 WRP ENERGY INC Brine 17 365
1992 WRP ENERGY INC Brine 0 365
1993 EVERFLOW EASTERN PARTNERS LP Brine 0 365
1994 EVERFLOW EASTERN PARTNERS LP Brine 0 353
1995 EVERFLOW EASTERN PARTNERS LP Brine 0 365
1996 EVERFLOW EASTERN PARTNERS LP Brine 0 365
1997 EVERFLOW EASTERN PARTNERS LP Brine 35 365
1998 EVERFLOW EASTERN PARTNERS LP Brine 0 365
1999 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2000 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2001 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2002 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2003 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2004 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2005 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2006 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2007 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2008 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2009 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2010 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2011 EVERFLOW EASTERN PARTNERS LP Brine 0 197
2012 EVERFLOW EASTERN PARTNERS LP Brine 0 156
2013 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2014 EVERFLOW EASTERN PARTNERS LP Brine 34 335
2015 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2016 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2017 EVERFLOW EASTERN PARTNERS LP Brine 0 365
2018 EVERFLOW EASTERN PARTNERS LP Brine 25 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-962976799 2007-12-18 0:00 PW No Violations
000PL12490 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0962976799 2007-12-18 Production Wells No Violations I performed a random field inspection. GPSd the well and the tank battery for the first time. The ID sign was posted. The tank battery was in good shape. There were no violations at this time.
1522947192 2018-04-02 Production Wells No Violations The purpose of my inspection was to conduct a status check on well #2-2344. RBDMS indicated reported production was current. Access to the well and tank battery was immediately off of a paved street. Correct identification was present at the well head. The 8.625 well was plumbed above grade and pipelined to the tank battery. The 4.5 production casing was equipped with a plunger lift assembly. Production valves were in the open position. No leaks were observed. The tank battery was protected from collision by a steel guiderail. A stable earthen dike that was free of fluid was present around the equipment. Equipment within the dike consisted of one (1) horizontal separator and two (2) 50 bbl production tanks. The separator remained in good repair and contained a current 7 day production chart. Correct identification was posted on the door. The production tanks remained in good repair. Valves were closed and plugged. Hatch lids were closed. No violations were observed during this inspection.
PL12490 PL No Violations

For data sources see[9]

References