If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-099-22469 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.01,"lon":-80.71,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Mahoning | |
Municipality: Boardman Township | |
Operator Name: EVERFLOW EASTERN PARTNERS LP | |
Well Pad ID: | |
Farm/Lease Name: HIGH POINT DEVELOPMENT | |
License Status: Producing | |
License Date: 1991-04-04 | |
Spud Date: 1991-09-27 | |
Spud Drilling Contractor: [[JL COATS [COATS-GOFF]]] | |
Final Drill Date: 1991-10-12 | |
Well Total Depth: 5991.00 ft | |
Configuration: Directional | |
Latitude: 41.010000 | |
Longitude: -80.710000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1991-04-04 | 84 EVERFLOW EASTERN PTNS L P GeoDate 4/4/91 |
Oil and Gas | 1991-04-04 | Issued Date 4/4/91 Expired Date 4/3/92 Acres 0047020 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 05991 Proposed Drill Depth 05991 |
Original Spud | 1991-09-27 | CHG FTG &XY 7-4-92 |
Completed | 1991-10-12 | CHG FTG &XY 7-4-92 |
Reached Total Depth | 1991-10-12 | CHG FTG &XY 7-4-92 |
Completion Report Received | 1991-12-10 | CHG FTG &XY 7-4-92 |
Construction Permit Expires | 1992-04-03 | CHG FTG &XY 7-4-92 |
Record Last Modified | 2017-02-15 | CHG FTG &XY 7-4-92 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 5698 | 5768 | 55 |
5699 | 5766 | 0 | |
1997-06-29 | 5699 | 5766 | 0 |
5698 | 5768 | 55 | |
5698 | 5768 | 55 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 121380 Gal | 80000 | FRAC W/121,380 GAL H20 & 80M# SAND |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-675116437 | 2010-10-7 0:00: | PW | No Violations | |
0000002157 | Preliminary Restoration | No Violations | PASSED Y WITNESSED 12/31/92 INSPECTOR BRETT FARNSWORTH DATE 12/3119/92 DATA FROM OLD VAX INFO | |
0257808273 | 2018-01-23 | Production Wells | No Violations | The purpose of my inspection was to conduct a status check on well #2-2469. RBDMS indicated the owner was current with production reporting. The well was located in a housing development. The well was enclosed within a locked chain-link fence cage that was obscured with landscaping at correct distances. Correct identification was present at the well head. The 8.625 well head was below grade. The annulus was plumbed above grade and closed to atmosphere. The 4.5 production casing was equipped with a plunger lift assembly. Production valves were in the closed position. No leaks were observed. The tank battery was shared with #2-2192. Lease operator John Morse at the tank battery for maintenance on the separator of well #2-2192. A stable earthen dike that was free of fluid was present around the production equipment. Equipment within the dike specific to # 2469 consisted of one (1) horizontal separator. A shared 100 bbl production tank was also present. The separator remained in good repair and contained a current 7 day production chart. The production tank remained in good repair with correct identification for both wells. Valves were closed and plugged. No violations were observed during this inspection. |
0675116437 | 2010-10-07 | Production Wells | No Violations | I performed a random field inspection. I GPSd both the tank battery and the wellhead for the first time. I continued to walk around both the wellhead and the tank battery. This inspection satisfies 1501:9-9-05. There were no violations at this time. |
2157 | PL | No Violations | ||
257808273 | 2018-1-23 0:00: | PW | No Violations | 0.30 |
For data sources see[9]