If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-099-22495 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.02,"lon":-80.67,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Mahoning | |
Municipality: Boardman Township | |
Operator Name: EVERFLOW EASTERN PARTNERS LP | |
Well Pad ID: | |
Farm/Lease Name: DUNDICS UNIT | |
License Status: Producing | |
License Date: 1991-11-25 | |
Spud Date: 1991-09-01 | |
Spud Drilling Contractor: [[JL COATS [COATS-GOFF]]] | |
Final Drill Date: 1991-09-11 | |
Well Total Depth: 6010.00 ft | |
Configuration: Directional | |
Latitude: 41.020000 | |
Longitude: -80.670000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1991-07-26 | 84 EVERFLOW EASTERN PTNS L P GeoDate 7/26/91 |
Oil and Gas | 1991-07-26 | Issued Date 7/26/91 Expired Date 7/25/92 Acres 0087480 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 06010 Proposed Drill Depth 06010 |
Original Spud | 1991-09-01 | REVISE UNIT 11-30-91, CORR. IN FTG, ACR, ELV. X&Y 9-19-92 |
Completed | 1991-09-11 | REVISE UNIT 11-30-91, CORR. IN FTG, ACR, ELV. X&Y 9-19-92 |
Reached Total Depth | 1991-09-11 | REVISE UNIT 11-30-91, CORR. IN FTG, ACR, ELV. X&Y 9-19-92 |
Completion Report Received | 1991-10-07 | REVISE UNIT 11-30-91, CORR. IN FTG, ACR, ELV. X&Y 9-19-92 |
CO | 1991-11-25 | 84 EVERFLOW EASTERN PTNS L P GeoDate 11/25/91 |
Oil and Gas | 1991-11-25 | Issued Date 11/25/91 Expired Date 11/24/92 Acres 0087550 Tool Type RTAF Proposed Formation CLINTON Proposed Depth Proposed Drill Depth |
Construction Permit Expires | 1992-11-24 | REVISE UNIT 11-30-91, CORR. IN FTG, ACR, ELV. X&Y 9-19-92 |
Record Last Modified | 2017-02-15 | REVISE UNIT 11-30-91, CORR. IN FTG, ACR, ELV. X&Y 9-19-92 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 5711 | 5807 | 0 |
5711 | 5807 | 0 | |
2006-09-11 | 5712 | 5788 | 50 |
5712 | 5788 | 50 | |
5711 | 5807 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 119000 Gal | 80000 | FRAC W/119M GAL H20 & 800 SX SAND |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1542028820 | 2004-5-26 0:00: | PW | No Violations | 0.50 |
-1877096764 | 2017-12-13 0:00 | PW | No Violations | 0.50 |
0000011960 | Preliminary Restoration | No Violations | PASSED Y WITNESSED 7/20/92 INSPECTOR BRETT FARNSWORTH DATE 07/2019/92 DATA FROM OLD VAX INFO | |
11960 | PL | No Violations | ||
1245263653 | 2009-06-17 | Production Wells | No Violations | I walked around the tank battery and the wellhead and found that there were no violations at this time. |
1542028820 | 2004-05-26 | Production Wells | No Violations | The tank battery is shared with permits: 2494, and 2627 and consists of 1-100 bbl storage tank, 2-separators a dike and a fence. |
1877096764 | 2017-12-13 | Production Wells | No Violations | The purpose of my inspection was to conduct a status check on well #2-2495. Inspector John Fleming was present during the inspection. A review of RBDMS indicated production reporting was current. Access to the well was through a residential yard. The well head and tank battery were enclosed by a locked chain-link fence enclosure. Correct identification was present. The 8.625 well head was above grade and plumbed into the flow line. The connection valve was closed at the time of inspection. The 4.5 production casing was equipped with a plunger lift assembly. Production valves were in the closed position. No leaks were observed. The tank battery was shared with #2-2627 and #2-2494. All equipment was within a locked chain-link fence enclosure obscured by landscaping. Correct identification was present. A stable earthen dike that was free of fluid was present around the equipment. Equipment within the dike consisted of two (2) horizontal separators and one (1) 100 bbl production tank. The separators remained in good repair. The production tank remained in good repair. Valves were closed and plugged. A domestic supply connection was present. No violations were observed during this inspection. |
For data sources see[9]