If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-099-22541 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.04,"lon":-80.65,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Mahoning | |
Municipality: Boardman Township | |
Operator Name: EVERFLOW EASTERN PARTNERS LP | |
Well Pad ID: | |
Farm/Lease Name: STROHECKER | |
License Status: Producing | |
License Date: 1992-07-31 | |
Spud Date: 1992-09-22 | |
Spud Drilling Contractor: MOHAWK DRLG | |
Final Drill Date: 1992-10-02 | |
Well Total Depth: 5650.00 ft | |
Configuration: Vertical | |
Latitude: 41.040000 | |
Longitude: -80.650000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1992-07-31 | 84 EVERFLOW EASTERN PTNS L P GeoDate 7/31/92 |
Oil and Gas | 1992-07-31 | Issued Date 7/31/92 Expired Date 7/31/93 Acres 0041810 Tool Type RTF Proposed Formation CLINTON Proposed Depth 05650 Proposed Drill Depth 05650 |
Original Spud | 1992-09-22 | |
Completed | 1992-10-02 | |
Reached Total Depth | 1992-10-02 | |
Completion Report Received | 1992-10-19 | |
Construction Permit Expires | 1993-07-31 | |
Record Last Modified | 2015-09-24 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 5347 | 5416 | 50 |
5347 | 5416 | 50 | |
5347 | 5416 | 50 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 120700 Gal | 80000 | AVG RATE 41.5 BPM; |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1076387548 | 2007-11-14 0:00 | PW | No Violations | |
-1688488528 | 2012-2-2 0:00:0 | UP | No Violations | |
-643630488 | 2004-1-20 0:00: | PW | No Violations | 0.50 |
0000016822 | Preliminary Restoration | No Violations | PASSED Y WITNESSED 5/27/93 INSPECTOR BRETT FARNSWORTH DATE 05/2719/93 DATA FROM OLD VAX INFO | |
0643630488 | 2004-01-20 | Production Wells | No Violations | The tank battery consists of: 2-100 bbl storage tank, 1-50 bbl salt water tank, 3-separators and a dike. The tank battery is shared with permits: 2951 and 2811. |
1076387548 | 2007-11-14 | Production Wells | No Violations | I preformed a random field inspection. GPSd both the well and the tank battery. ID signs were posted. The tank battery was in very good shape. There were no violations at this time. |
1347473308 | 2012-09-11 | Production Wells | No Violations | On 9/11/2012, I performed a status check on the above well site. The tank battery is equipped with one horizontal separator. The well shares the same tank as the 3409922811 Youngtowns Christian School #1. This is a plunger lift with 1.5 tubing, there is 0 psi on the 8.625. Identification signs are posted. No violation were noted at this time. |
16822 | PL | No Violations | ||
1688488528 | 2012-02-02 | UrbanProduction Wells | No Violations | I conducted a status check on this site and found that the well head was fenced with chain link, and it is equipped with a plunger lift system. The tank battery consists of one 100 barrel stock tank, and three separators, no brine storage tank present. The thief hatch was closed and there was a bull plug installed in the draw valve. The tank battery was fenced with chain link, and the dike was free of vegetation and debris. The tank battery is shared with permits 2951, and 2811. Proper identification was posted, and I found no leaks or spills at the well head or the tank battery. I took new GPS coordinates of the well head and tank battery. No violations at this time. |
For data sources see[9]