X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-053-20657

Well Details

Well ID: 34-053-20657
Loading map...
Country: United States
State: Ohio
County: Gallia
Municipality: Cheshire Township
Operator Name: J T PLUS WELL SERVICE LLC
Well Pad ID:
Farm/Lease Name: SWISHER SUSIE
License Status: Producing
License Date: 1981-04-07
Spud Date: 1981-07-27
Spud Drilling Contractor:
Final Drill Date: 1981-07-30
Well Total Depth: 1874.00 ft
Configuration: Vertical
Latitude: 38.940000
Longitude: -82.150000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1981-04-07 137 ALTHEIRS OIL INC GeoDate 4/7/81
Original Spud 1981-07-27 INSPECTED NOVEMEBER 5, 2005 BY LINDA SLATER. WELL IS TURNED ON; LANDOWNER HAS SEEN PUMP JACK OPERATING.
Completed 1981-07-30 INSPECTED NOVEMEBER 5, 2005 BY LINDA SLATER. WELL IS TURNED ON; LANDOWNER HAS SEEN PUMP JACK OPERATING.
Reached Total Depth 1981-07-30 INSPECTED NOVEMEBER 5, 2005 BY LINDA SLATER. WELL IS TURNED ON; LANDOWNER HAS SEEN PUMP JACK OPERATING.
Record Last Modified 2013-10-03 INSPECTED NOVEMEBER 5, 2005 BY LINDA SLATER. WELL IS TURNED ON; LANDOWNER HAS SEEN PUMP JACK OPERATING.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 1795 1806 1
1795 1806 1
1795 1806 1

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
GEL 0 500 Lbs 30000 J-266

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 ALTHEIRS OIL INC 4462.00 0.00 365
1985 ALTHEIRS OIL INC 2429.00 0.00 260
1986 ALTHEIRS OIL INC 1682.00 0.00 365
1987 ALTHEIRS OIL INC 1900.00 0.00 365
1988 ALTHEIRS OIL INC 2322.00 0.00 365
2009 ALTHEIRS OIL INC 355.00 0.00 365
2010 ALTHEIRS OIL INC 291.00 0.00 365
2011 ALTHEIRS OIL INC 33.00 0.00 365
2012 ALTHEIRS OIL INC 0.00 0.00 366
2013 ALTHEIRS OIL INC 85.00 0.00 365
2014 ALTHEIRS OIL INC 0.00 0.00 365
2015 ALTHEIRS OIL INC 14.00 0.00 365
2016 ALTHEIRS OIL INC 0.00 0.00 365
2017 ALTHEIRS OIL INC 0.00 0.00 365
2018 ALTHEIRS OIL INC 0.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 ALTHEIRS OIL INC Brine 0 365
1985 ALTHEIRS OIL INC Brine 0 260
1986 ALTHEIRS OIL INC Brine 0 365
1987 ALTHEIRS OIL INC Brine 0 365
1988 ALTHEIRS OIL INC Brine 0 365
2009 ALTHEIRS OIL INC Brine 0 365
2010 ALTHEIRS OIL INC Brine 0 365
2011 ALTHEIRS OIL INC Brine 0 365
2012 ALTHEIRS OIL INC Brine 0 366
2013 ALTHEIRS OIL INC Brine 0 365
2014 ALTHEIRS OIL INC Brine 0 365
2015 ALTHEIRS OIL INC Brine 0 365
2016 ALTHEIRS OIL INC Brine 0 365
2017 ALTHEIRS OIL INC Brine 0 365
2018 ALTHEIRS OIL INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-276337475 2003-4-16 0:00: PW No Violations
-479404949 2014-5-28 0:00: PW No Violations 1.00
0217716977 2004-11-05 Production Wells No Violations Well is turned on; two IDs on tank for Altier - one is for this well. Gas to motor off but landowner has seen pump jack operating. Need to change status and ownership for this well.
0246147809 2007-05-21 Production Wells No Violations Id on tank is not complete needs the emergency phone #. Pump jack has a motor on it. Polish rod is shiny. Well is in production.
0276337475 2003-04-16 Production Wells No Violations No violations at the time of inspection.
0479404949 2014-05-28 Production Wells No Violations Upon inspection, it was observed that there is now legible and correct identification information posted at the tank battery for this well, which is approximately 75 from the well head. The R style well head setup is currently disconnected from the 1.5 tubing and is allowing the 2 fitting from the annulus to vent gas into the atmosphere. In addition, a small amount of oil and paraffin has leaked from this fitting onto the ground surrounding the well head. I will contact Altheirs Oil Inc. and notify them of the situation.
0718293254 2007-02-12 Production Wells Violations Noted Cannot read all of the Id. Pump jack motor is gone.
0754577175 2013-04-22 Production Wells No Violations FOLLOW UP TO NOV # 1396955695 This is a pumping unit wellhead. There was no identification sign at the wellhead. According to 1501:9-9-05(A)10/1509:23 the well identification sign shall include owners name, county, township, well name and number, permit number for the well, and emergency contact number. There is a t-fitting at the surface. There are two 2-1/4 inch pipe coming from the side connections of this fitting. A 1-7/8 inch production tubing rises above the cap of this fitting to another t-fitting. Out one side is a 2-1/4 inch production pipe. On the other side is a 1-1/8 inch tubing ending in a ball valve and plug. Attached on top of this fitting is the stuffing box assembly for the pumping unit. At present the wellhead has no motor. Tank battery next to the wellhead consists of one 100-barrel tank , one liquid/gas separator and a small knockout tank in the containment area. There is also no identification on anything in the tank battery.
1396955695 2013-04-22 Production Wells Violations Noted This is a pumping unit wellhead. There was no identification sign at the wellhead. According to 1501:9-9-05(A)10/1509:23 the well identification sign shall include owners name, county, township, well name and number, permit number for the well, and emergency contact number. There is a t-fitting at the surface. There are two 2-1/4 inch pipe coming from the side connections of this fitting. A 1-7/8 inch production tubing rises above the cap of this fitting to another t-fitting. Out one side is a 2-1/4 inch production pipe. On the other side is a 1-1/8 inch tubing ending in a ball valve and plug. Attached on top of this fitting is the stuffing box assembly for the pumping unit. At present the wellhead has no motor. Tank battery next to the wellhead consists of one 100-barrel tank , one liquid/gas separator and a small knockout tank in the containment area. There is also no identification on anything in the tank battery.
217716977 2004-11-5 0:00: PW No Violations
246147809 2007-5-21 0:00: PW No Violations
718293254 2007-2-12 0:00: PW No Violations
754577175 2013-4-22 0:00: PW No Violations 0.80

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0718293254 US-OH-128159 2007-02-14 Failure to legibly identify well
1396955695 US-OH-111739 2013-04-26 Failure to legibly identify well

For data sources see[9]

References