34-099-22995

Well Details

Well ID: 34-099-22995
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: AM-TEK OIL INC
Well Pad ID:
Farm/Lease Name: TOD HOMESTEAD CEMETERY
License Status: Producing
License Date: 2005-08-31
Spud Date: 2006-02-22
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2006-02-28
Well Total Depth: 5318.00 ft
Configuration: Vertical
Latitude: 41.130000
Longitude: -80.660000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-08-31 Proposed Formations:ORISKANY/CLINTON, Issued Date:8/31/2005, Expired Date:8/31/2006 6:00:00 AM, Drilling unit acres:161.91, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2006-02-22 RBDMS Rec
Completed 2006-02-28 RBDMS Rec
Reached Total Depth 2006-02-28 RBDMS Rec
Completion Report Received 2006-05-01 RBDMS Rec
Construction Permit Expires 2006-08-31 RBDMS Rec
Record Last Modified 2015-09-24 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-07-13 3549 3559 20
2006-07-13 5130 5247 75
3549 3559 20
5130 5247 75
3549 3559 20

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 15 1000 Gal 0
H2O 15 75000 Gal 0 500 GALLONS HCL ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 DUCK CREEK ENERGY INC 2020.00 83.00 210
2007 DUCK CREEK ENERGY INC 8755.00 356.00 365
2008 DUCK CREEK ENERGY INC 8306.00 212.00 365
2009 DUCK CREEK ENERGY INC 6414.00 152.00 365
2010 DUCK CREEK ENERGY INC 8976.00 126.00 365
2011 DUCK CREEK ENERGY INC 9425.00 164.00 365
2012 DUCK CREEK ENERGY INC 8090.00 163.00 366
2013 DUCK CREEK ENERGY INC 5561.00 29.00 365
2014 DUCK CREEK ENERGY INC 3736.00 86.00 365
2015 DUCK CREEK ENERGY INC 3436.00 29.00 365
2016 DUCK CREEK ENERGY INC 4604.00 122.00 365
2017 DUCK CREEK ENERGY INC 4018.00 153.00 365
2018 DUCK CREEK ENERGY INC 4615.00 76.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 DUCK CREEK ENERGY INC Brine 389 210
2007 DUCK CREEK ENERGY INC Brine 360 365
2008 DUCK CREEK ENERGY INC Brine 138 365
2009 DUCK CREEK ENERGY INC Brine 170 365
2010 DUCK CREEK ENERGY INC Brine 155 365
2011 DUCK CREEK ENERGY INC Brine 124 365
2012 DUCK CREEK ENERGY INC Brine 121 366
2013 DUCK CREEK ENERGY INC Brine 45 365
2014 DUCK CREEK ENERGY INC Brine 19 365
2015 DUCK CREEK ENERGY INC Brine 16 365
2016 DUCK CREEK ENERGY INC Brine 54 365
2017 DUCK CREEK ENERGY INC Brine 51 365
2018 DUCK CREEK ENERGY INC Brine 88 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1928631536 2006-3-7 0:00:0 DD No Violations 1.00
-225995770 2018-6-26 0:00: PW No Violations 0.50
-971473662 2007-4-5 0:00:0 PL No Violations
0225995770 2018-06-26 Production Wells No Violations The purpose of my inspection was to conduct a status check inspection on well #2-2994. Inspector John Fleming was present during the inspection. RBDMS indicated reported production was current. Access to the well and tank battery remained drivable and stable through the Tod Cemetery. The well was located within a locked chain-link enclosure that contained correct identification. The 8.625 well head was below grade. The 4.5 production casing was equipped with a plunger lift assembly. Production valves were in the open position. No leaks were observed. The tank battery was shared with #2-2995. A stable earthen dike that was free of fluid was present around the production equipment. A locked chain-link fence enclosure was present on top of the dike. Privacy screening on the fence was deteriorated. Correct identification was present on the fence. Equipment on location consisted of two (2) vertical separators and two (2) 140 bbl production tanks. The separators remained in good repair. No production charts were present. The production tanks remained in good repair. Valves were closed and plugged. Staining consistent with a legacy operation was present. A charcoal filter was present. Hatch lids were closed. No violations were observed during this inspection.
0235043984 2018-12-26 Production Wells No Violations I performed status check inspection on the above well. This well was converted from a plunger lift to Pumping Unit. Access to the well and tank battery remained drivable and stable through the Tod Cemetery. The well was located within a locked chain-link enclosure that contained correct identification. The 8.625 well head was below grade. The 4.5 production casing was equipped with a plunger lift assembly. Production valves were in the open position. No leaks were observed. A stable earthen dike that was free of fluid was present around the production equipment. A locked chain-link fence enclosure was present on top of the dike. Privacy screening on the fence was deteriorated. Correct identification was present on the fence. Equipment on location consisted of one vertical separators and one 140 bbl production tanks. The separators remained in good repair. No production charts were present. The production tanks remained in good repair. Valves were closed and plugged. A charcoal filter was present. Hatch lids were closed. No violations were observed during this inspection.
0311278558 2006-05-08 Preliminary Restoration No Violations The tank battery is shared with Permit: 2994 and consists of 2-100 bbl storage tanks, 2-separators, a fence and a dike that is not fully enclosed. The well is not in production as yet. The pits are closed. Partial compliance for preliminary restoration.
0971473662 2007-04-05 Preliminary Restoration No Violations There was good vegetation growth on the location. The drilling pits were filled in. There was no erosion on location or lease road. All the debris was removed from the location. There was no drilling equipment on location. This well and tank battery has passed preliminary restoration.
1928631536 2006-03-07 Drill / Deepen / Reopen No Violations The drilling is completed. The rig is pulling out of the hole at this time. Met with Brad Nelson. The rig is going to move over to the 3-D on Wednesday.
235043984 2018-12-26 0:00 PW No Violations 1.00
311278558 2006-5-8 0:00:0 PL No Violations 0.50

For data sources see[9]