Well Details

Well ID: 34-157-23690
Loading map...
Country: United States
State: Ohio
County: Tuscarawas
Municipality: Warren Township
Operator Name: BRINE X LLC
Well Pad ID:
Farm/Lease Name: GRIMM R D & M K
License Status: Active Injection
License Date: 1981-12-31
Spud Date: 1982-04-16
Spud Drilling Contractor: CUBBY DRLG
Final Drill Date: 1982-04-19
Well Total Depth: 1129.00 ft
Configuration: Vertical
Latitude: 40.480000
Longitude: -81.270000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Conversion to Injector 1981-12-31
Original Spud 1982-04-16 ORIGINAL INJECTION RATE WAS 850 UNTIL STEP RATE TEST.
Completed 1982-04-19 ORIGINAL INJECTION RATE WAS 850 UNTIL STEP RATE TEST.
Reached Total Depth 1982-04-19 ORIGINAL INJECTION RATE WAS 850 UNTIL STEP RATE TEST.
First Injection 1983-04-20 ORIGINAL INJECTION RATE WAS 850 UNTIL STEP RATE TEST.
Annulus Pressure Monitoring Approved 1989-09-14 ORIGINAL INJECTION RATE WAS 850 UNTIL STEP RATE TEST.
Water Analysis 1991-10-01 ORIGINAL INJECTION RATE WAS 850 UNTIL STEP RATE TEST.
Last Compliance Report 1999-08-23 ORIGINAL INJECTION RATE WAS 850 UNTIL STEP RATE TEST.
Change of Owner 2001-05-09 Operator changed from 18, MUTUAL OIL & GAS CO to 6288, ALLIANCE PETROLEUM CORPORATION
Change of Owner 2001-05-17 Operator changed from 6288, ALLIANCE PETROLEUM CORPORATION to 3606, LONG DANNY L & SONS
Change of Owner 2011-04-19 Operator changed from 3606, LONG DANNY L & SONS to 8785, BRINE X LLC
Record Last Modified 2017-10-19 ORIGINAL INJECTION RATE WAS 850 UNTIL STEP RATE TEST.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-05-08 953 1025 1
953 1025 1
953 1025 1

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 65000 Gal 0

For data sources see[4]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1013190484 2016-3-10 0:00: SW No Violations
-1099396859 2010-6-22 0:00: SW No Violations 1.50
-1099929043 2013-9-25 0:00: SW No Violations
-1153428017 2016-6-17 0:00: SW No Violations
-115358928 2020-6-9 0:00:0 SW No Violations
-1158800595 2012-6-15 0:00: SW No Violations 2.00
-1180012301 2020-1-16 0:00: SW No Violations
-1183480051 2010-6-3 0:00:0 SW No Violations 1.50
-1192906281 2014-10-6 0:00: SW No Violations
-1275858834 2006-9-18 0:00: SW No Violations 1.50
-1332378261 2008-10-21 0:00 SW No Violations 1.50
-1345806214 2006-7-18 0:00: SW No Violations 1.00
-1394765833 2005-12-29 0:00 SW No Violations 1.50
-140412793 2006-4-4 0:00:0 SW No Violations 1.50
-1458088986 2012-6-15 0:00: SW No Violations 2.00
-1465417987 2006-7-12 0:00: SW No Violations 1.50
-1483530289 2007-12-13 0:00 SW No Violations 1.50
-1504472582 2010-3-12 0:00: SW No Violations 1.50
-1600533865 2018-3-25 0:00: SW No Violations
-1610120669 2018-7-5 0:00:0 SW No Violations
-1626569667 2018-1-24 0:00: SW No Violations
-164042906 2012-2-1 0:00:0 SW No Violations 1.50
-1662293855 2015-2-13 0:00: SW No Violations
-1668071416 2014-8-12 0:00: SW No Violations
-1669898950 2005-3-9 0:00:0 SW No Violations 1.50
-1689775962 2009-7-28 0:00: SW No Violations 1.50
-1734309034 2003-7-10 0:00: SW No Violations 1.20
-1743059147 2011-8-3 0:00:0 SW No Violations 1.50
-1764013913 2012-6-15 0:00: SW No Violations 2.00
-1770650519 2010-4-30 0:00: SW No Violations 1.50
-1782101583 2006-11-2 0:00: SW No Violations 1.50
-1888060693 2017-2-23 0:00: SW No Violations
-1906454793 2016-10-21 0:00 SW No Violations
-1917755047 2013-12-4 0:00: SW No Violations
-1919004635 2007-8-13 0:00: SW No Violations 1.50
-1945274500 2009-2-26 0:00: SW No Violations 1.50
-1954447460 2010-3-31 0:00: SW No Violations 2.20
-2030724151 2011-6-7 0:00:0 SW No Violations 1.50
-2039726553 2020-7-14 0:00: SW No Violations
-207430216 2008-6-19 0:00: SW No Violations 1.50
-2105666876 2013-10-24 0:00 SW No Violations
-2127758262 2007-4-10 0:00: SW No Violations 1.50
-273739068 2008-2-21 0:00: SW No Violations 1.50
-27980904 2014-3-21 0:00: SW No Violations
-293438266 2007-11-14 0:00 SW No Violations 1.50
-351334508 2016-11-14 0:00 SW No Violations
-355546005 2013-11-15 0:00 SW No Violations
-372660631 2017-4-25 0:00: SW No Violations
-495154316 2017-10-3 0:00: SW No Violations
-499110852 2004-9-3 0:00:0 SW No Violations 1.50
-503599932 2011-10-31 0:00 SW No Violations 1.50
-517720735 2016-11-10 0:00 SW No Violations
-567790410 2016-12-15 0:00 SW No Violations
-576327828 2009-12-9 0:00: SW No Violations 1.50
-591729436 2016-3-16 0:00: SW No Violations
-634683694 2007-2-23 0:00: SW No Violations 1.50
-674931662 2017-7-25 0:00: SW No Violations
-692609866 2006-12-5 0:00: SW No Violations 1.00
-717415048 2012-7-24 0:00: SW No Violations 2.50
-75318899 2010-4-27 0:00: SW No Violations 1.50
-758552912 2015-5-11 0:00: SW No Violations
-803235320 2003-9-17 0:00: SW No Violations 1.50
-846326160 2012-6-18 0:00: SW No Violations 1.50
-871355011 2009-6-17 0:00: SW No Violations 1.50
-93124975 2014-11-18 0:00 SW No Violations
-954649468 2012-6-25 0:00: SW No Violations 2.50
-985029680 2005-6-23 0:00: SW No Violations 1.70
-988682290 2012-7-17 0:00: SW No Violations 1.50
0000000279 2002-08-08 Production Wells No Violations no violations
0000UIC326 1987-09-14 Salt Water Injection Well No Violations 1501:9-3-07 (E)(F)
0001239i28 Salt Water Injection Well No Violations
0001239i75 Salt Water Injection Well No Violations New well owners are Long and Sons. The well appears to be operationg at a much higher pressure than previously.This well will need more inspections to assure that the well remains in compliance.
0002875874 Salt Water Injection Well No Violations
0007575909 Salt Water Injection Well No Violations New well owners are Long and Sons. The well appears to be operationg at a much higher pressure than previously.This well will need more inspections to assure that the well remains in compliance.
000UIC1804 1999-11-03 Salt Water Injection Well No Violations RESTORATION
0010889905 2016-05-16 Salt Water Injection Well No Violations Inspection revealed that well is down for injection pump repairs.
001252i279 2002-08-08 Production Wells No Violations no violations
0014575993 2002-02-25 Salt Water Injection Well No Violations Found well in operation during inspection. I also found a brine kill area from and old spill tnat needs to be re-graded and seeded. The area is just below the pumphouse and is 10ft. X 20ft. This is something that should wait until spring to be done.
0018476039 2002-03-26 Salt Water Injection Well No Violations Met Danny Long on site and reviewed brine kill area and how to remediate soil next to building .He is going to wait for better weather before he begins.
0027980904 2014-03-21 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today and it was noted that one Resource America vacuum truck was unloading at facility during my inspection.
0032076122 2002-07-08 Salt Water Injection Well No Violations Arrive and found that well is in operation and that the small spill has been cleaned up but vegetaion in that area is still affected. This area is below the pumphouse and are about 10 ft x 20 ft. that should be reseeded.
0038876007 2002-08-20 Salt Water Injection Well No Violations The area below the pump house has been graded and seeded but due to the daught it will most likely need redone this fall or spring.
0046476279 2002-10-16 Salt Water Injection Well No Violations Area around the front of gate entrance for tank battery has been dug up and needs seeded . The area below pump could also use reseeded .
0047576224 2002-10-29 Salt Water Injection Well No Violations Check to see if any grading or seeding has been done and found none ., Issue nov to grade seed and place clean fill down with mulch for cover .
0072695184 2013-08-02 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it was noted that 2-210 bbl tanks have been replaced since my last inspection and it was noted that new vault has been installed also,called and discussed upgrades that were made at facility since my last inspection.
0073957209 2007-01-22 Salt Water Injection Well No Violations
0075318899 2010-04-27 Salt Water Injection Well No Violations No work done on repairs to this facility , this well is not in operation at this time.
0093124975 2014-11-18 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today due too extreme cold weather and it was noted that one Resource Well Service vacuum truck was unloading at the facility during my inspection.
0140412793 2006-04-04 Salt Water Injection Well No Violations
0164042906 2012-02-01 Salt Water Injection Well No Violations The well head chart has not been removed. And the well does not appear to be in operation. It had 0 pressure (not vacuum). I checked the annulus which had 0 pressure, not even a puff or hiss. I have found this only in wells that had the annulus blocked.
0197010902 2012-06-15 Salt Water Injection Well No Violations FOLLOW UP TO NOV # -1458088986 I arrived to check this facility and during my inspection I found that a brine spill has occurred just below the pump house. The spill is 10 ft wide for most of the length and almost 110 ft long. The soil is dry now and the
0207430216 2008-06-19 Salt Water Injection Well No Violations Does not appear to be in operation at this time.
0252819223 2011-03-16 Salt Water Injection Well No Violations Well does not appear to be in operation. The chart has not been changed and the pressure has been at 0 for over one week or more.
0273739068 2008-02-21 Salt Water Injection Well No Violations Looks like the cold has all of the disposal wells shut in or not trying to operate.
0293438266 2007-11-14 Salt Water Injection Well No Violations
0295625483 2013-03-08 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today and it was noted that disconnected storage tank still needs to be removed from site when weather permits access to tank pad.
0351334508 2016-11-14 Salt Water Injection Well No Violations Knox Energy service rig on site preparing to release packer and remove from wellbore they suspect that they have packer failure or tubing failure and once determined what the problem is they will replace with new tubing and packer.
0354133688 2015-07-30 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation on the day of my inspection.
0355546005 2013-11-15 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it was noted tat unloading pad has been cleaned since my last inspection.
0372660631 2017-04-25 Salt Water Injection Well No Violations Inspection revealed that well is down due to injection pump being replaced.
0390985403 2010-05-10 Salt Water Injection Well No Violations There has been no repairs to this facility and operator told me because it has rained so much he is waiting for few dry days.
0394087585 2016-02-01 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation and it was noted that one J-Hawk water services was unloading at the facility during my inspection.
0395037609 2010-04-13 Salt Water Injection Well No Violations No work has been done on the dike and leaking tanks
0454135625 2017-12-26 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation and operating at maximum allowable pressure.
0475052711 2006-06-13 Salt Water Injection Well No Violations Inspection revealed that the injection pressure is 40 psi and the annulus pressure is zero psi. No violations at this time .
0487062907 2012-07-03 Salt Water Injection Well No Violations The well is not in operation at this time. No workers are on site and no further work has been done to install vault below the pump house.
0495154316 2017-10-03 Salt Water Injection Well No Violations On site today to witness Knox Energys service rig wash obstruction out of wellbore and once they reached bottom they pulled out tubing and then they ran Baker packer back into well and they performed acid treatment on said well and new setting depth of packer is 932 set in 15K tension and MIT test was completed@960 psi with no pressure loss during test period.
0499110852 2004-09-03 Salt Water Injection Well No Violations The flow meter is locked inside the building and I do not have the key.
0503599932 2011-10-31 Salt Water Injection Well No Violations The chart on the injection well has been removed and well does not appear to be in operation.
0517720735 2016-11-10 Salt Water Injection Well No Violations Inspection revealed that injection pump has been removed from site it is being repaired well is down for pump replacement.
0553253892 2008-01-09 Salt Water Injection Well No Violations
0567790410 2016-12-15 Salt Water Injection Well No Violations Inspection revealed that well is not in operation at this time electrical work is being performed in the pump house.
0576327828 2009-12-09 Salt Water Injection Well No Violations
0591346252 2010-10-04 Salt Water Injection Well No Violations Well does not appear to be in operation again.
0591729436 2016-03-16 Salt Water Injection Well Violations Noted Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on February 15th for 2015, despite a letter that was sent March 1, 2016 with a deadline of March 15, 2016 to submit the reports requested. REPORTS RECEIVED 3/17/2016.
0634683694 2007-02-23 Salt Water Injection Well No Violations Pressure is at the maximum and should be monitored as not to exceed limits .
0652320928 2015-11-25 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.
0674931662 2017-07-25 Salt Water Injection Well No Violations Well is down awaiting on electrical repairs to be made.
0692609866 2006-12-05 Salt Water Injection Well No Violations
0717415048 2012-07-24 Salt Water Injection Well No Violations Arrive today to conduct a mini mechanical integrity test. Test well to 820 psi and 1st test failed. Test again to 820 psi and 2nd test passed. Contact Tom Tomastik and advise of good test.
0758552912 2015-05-11 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today and it appeared that well is not used much at this time.

Note: There was a previous violation issued for this well but has since been resolved.

0780215784 2003-04-14 Salt Water Injection Well No Violations
0803235320 2003-09-17 Salt Water Injection Well No Violations
0846326160 2012-06-18 Salt Water Injection Well No Violations No clean up has started to removed the contaminated area below the pumphouse. Contact Mike Demantio and set up meeting to begin clean up of entire area.
0852878597 2018-09-11 Salt Water Injection Well No Violations Injection pump is down for repair.
0859037620 2011-09-22 Salt Water Injection Well No Violations The well does not appear to be in operation. The chart has not been changed since my last two inspections.
0867805541 2012-10-24 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during this inspection, it was noted that old storage tanks at facility still needs to be removed from site and new tanks put in place and dike work needs to be preformed.

Note: On site to witness mini test on annulus of tubing Jayhawk Water on site with pressure pump to apply pressure on tubing they pressured up to 520 psi and we monitored pressure for 15 minutes with no decline in pressure.

0869372390 2012-04-17 Salt Water Injection Well No Violations I notified the operator of a very small line leak inside the dike. It is hooked up to the production tanks next to the unloading pad. The affected area of the leak was approximately the size of a sheet of paper. It has not been cleaned up but is not leaking any longer. The annulus pressure is 0 PSI and I need to witness a monthly annulus test to verify that there is not a problem.
0871355011 2009-06-17 Salt Water Injection Well No Violations Met operator and Carl Merricks boy on location.
0878868152 2015-10-20 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today and it was noted that owner still needs to replace 1-210 bbl.tank within dike area.
0954649468 2012-06-25 Salt Water Injection Well Violations Noted I arrived today to conduct a mini test on the injection well annulus and review the clean up of the brine spill which I found on 6/15/2012. The area of the brine spill has been graded but the contaminated soil has not been removed as requested. Mike Demantio said that the contamination of the soil was very slight and he feels it will grow grass. I advised if it did not green up very quickly it would need to be removed. J Hawk water service pumped up the injection annulus and during the pressure test the mini test failed. The 4 1/2 casing had 3 pin hole leaks which caused the test to fail. Mike Demantio said that after the service rig was done on the Stephenson that it would come here next.
0985029680 2005-06-23 Salt Water Injection Well No Violations
0988682290 2012-07-17 Salt Water Injection Well No Violations I arrived today to make sure well has not been placed back in operation. I found that it is not in operation at this time. Check on vegetaion and found that the area of the spill below the pump house still has low to no vegetation. Contact Bruce Levengood and advise he needs to establish vegetaion and install a vault below pump house.
1013190484 2016-03-10 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it was noted that one Resource Well Services vacuum truck was unloading at the facility during my inspection.

Note: Dike work still needs to be done at the facility.

1014787174 2007-10-10 Salt Water Injection Well No Violations
1024776151 2019-9-6 0:00:0 SW No Violations
1046364656 2006-01-20 Salt Water Injection Well No Violations Well appears to be on restriction .The chart shows no injection for a while.
1048865433 2003-03-24 Salt Water Injection Well No Violations Found well operating above maximum operating pressure and advised pressure be reduced asap . I also advised that the 1/4 inch tap valve on pressure side be repaired or replaced because it does not shut properly .
1063435915 2012-11-23 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it is noted that unloading pad is in need of a good cleaning.
10889905 2016-5-16 0:00: SW No Violations
1089845000 2002-12-31 Salt Water Injection Well No Violations During my inspection I found that the area below dike and next to pumphouse has been graded and reseeded . The area now has vegetation and should continue to improve by spring .
1099396859 2010-06-22 Salt Water Injection Well No Violations The tanks inside the dike have been replaced and the side of the dike has been repaired.
1099929043 2013-09-25 Salt Water Injection Well No Violations Inspection revealed tat injection pump was not in operation during my inspection and it was noted that J-Hawk Water was transferring water from vault tank to storage tanks during my inspection.
1153428017 2016-06-17 Salt Water Injection Well No Violations Inspection today revealed that injection pump was not in operation and it was noted that owner has not made upgrades to dike as discussed in previous conversations.
1158800595 2012-06-15 Salt Water Injection Well No Violations FOLLOW UP TO NOV # 197010902 FOLLOW UP TO NOV # -1458088986 I arrived to check this facility and during my inspection I found that a brine spill has occurred just below the pump house. The spill is 10 ft wide for most of the length and almost 110 ft long. The soil is dry now and the
1177845985 2015-12-31 Salt Water Injection Well No Violations Inspection revealed that owner has changed out two storage tanks as requested from previous inspections at the site but they will need to build up dike walls around tanks to become into compliance with SPCC rules.
1183480051 2010-06-03 Salt Water Injection Well No Violations
1192906281 2014-10-06 Salt Water Injection Well No Violations Inspection revealed that injection pump is down and waiting on replacement parts to repair crankshaft and one plunger on cylinder number two.
1223398153 2008-04-01 Salt Water Injection Well No Violations Does not look like well is in operation.Unloading pad blocked off and does not appear trucks hauling .
1239i28 SW No Violations 1.00
1239i75 SW No Violations 1.20
1252i279 2002-8-8 0:00:0 PW No Violations
1267795917 2010-02-19 Salt Water Injection Well No Violations Too much snow to get anything in or out of lease road.Well is not in operation.
1270209811 2010-03-31 Salt Water Injection Well Violations Noted During my inspection I found that one of the tanks may be leaking out the bottom. I also found that the dike has a groundhog hole in it. The groundhog and the hole will need removed. The overall height of the dike will need to be raised as well.
1275858834 2006-09-18 Salt Water Injection Well No Violations
1286292284 2010-04-21 Salt Water Injection Well No Violations There has been no action taken on repairs to this facility at this time. Nothing done
1292115480 2012-10-03 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.
1294852565 2010-11-23 Salt Water Injection Well No Violations Chart just going round not being changed.
1307554722 2011-03-22 Salt Water Injection Well No Violations Crew on site to work on the tanks and the dike. Well has not been in operation for the last week.
1332378261 2008-10-21 Salt Water Injection Well No Violations This well does not appear to be in operation.
1333640104 2012-03-08 Salt Water Injection Well No Violations During my last 2 inspections of this site I found the annulus pressure at 0 psi. The pressure on the injection side is also 0 psi and is not on vacuum. I will call for and witness a monthly annulus test, as this is not normal.
1336494918 2012-04-11 Salt Water Injection Well No Violations I found that the injection side and the annulus both had zero pressure.
1343409103 2012-07-24 Salt Water Injection Well No Violations I am on site today to conduct a mini Mechanical Integrity Test on the annular space between the 4 1/2 inch casing and the 2 3/8 tubing. The annulus was pumped up to 820 psi. The 1st test failed. On the 2nd test, the annulus was pumped up to 820 psi and the pressure reduced to 810 psi where it remained until the test was completed. This would be less than the allowed .05% decline and is a positive test. The area, previously seeded, below the pump house has not produced any vegetation and should be excavated soon, re-seeded and mulched. Mike Demantio said that the vault was being constructed and will be installed next week. I advised Mike that I wanted to be on site for the construction and installation of the vault.
1345806214 2006-07-18 Salt Water Injection Well No Violations Well not in operation ?
1349442102 2012-06-28 Salt Water Injection Well No Violations This well is not in operation at this time. No work has been done on the dike or the installation of a vault below the pump house.
1369871697 2013-05-29 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and t was noted that injection pressure was near maximum allowable pressure and I called and discussed issues at well site with Nate Levengood and he stated he would look into getting issues resolved.
1370478702 2013-06-05 Salt Water Injection Well No Violations On site to witness pressure testing of annulus of tubing,Jawhawk Water used pressure pump on vacuum truck to perform test they pressured up to 500 psi and we monitored pressure for 15 minutes with no decline in pressure.

Note: Suggested to operator to remove old unused 210 bbl tank from dike area and then construct dike around pump house to prevent any contamination to nearby waterway.

1394765833 2005-12-29 Salt Water Injection Well No Violations
1396038983 2014-03-27 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.

Note: Called owner and requested that they have positive pressure applied to annulus of tubing.

14575993 2002-2-25 0:00: SW No Violations 1.20
1458088986 2012-06-15 Salt Water Injection Well Violations Noted I arrived to check this facility and during my inspection I found that a brine spill has occurred just below the pump house. The spill is 10 ft wide for most of the length and almost 110 ft long. The soil is dry now and the vegetation is dead. Someone has mowed the area but no clean up has been started. The operator has not contacted me to advise of any spills. I contacted Bruce Levengood and advised of the spill and issued a verbal notice. I later met with Mike Demantio and scheduled the clean up and a mini test on the annulus for Monday, 6/25/2012.
1465417987 2006-07-12 Salt Water Injection Well No Violations Well has not been in operation since my last inspection ?
1479509503 2016-11-16 Salt Water Injection Well No Violations On site to witness new tubing and a rebuilt Baker Set Lock run into well and setting depth was 884.75 and we tested annulus at 1010 psi with no decline in pressure and once test was completed owner had Producers Services perform 2500 gallon acid treatment on said well.
Note: Injection pump is being repaired at this time and owner will call before placing well back into operation.
1483530289 2007-12-13 Salt Water Injection Well No Violations Well shut down today?
1484249262 2017-01-12 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection and it does not appear that well is being used much at this time.
1484937022 2017-01-20 Salt Water Injection Well No Violations After replacing 2 valve on annulas of tubing head we applied 340 psi on it and monitored pressure for 15 minutes with no decline in pressure.

Note: On site to witness mini test and it passed.

1489917683 2017-06-15 Salt Water Injection Well No Violations Well is down for injection pump replacement.
1495747920 2017-05-25 Salt Water Injection Well No Violations Owner is currently in process of relacing injection pump at the site.
1499112201 2017-07-03 Salt Water Injection Well No Violations On site along with Jeff Finney company rep to apply positive pressure to annulus of tubing he applied 500 psi and we monitored pressure for 15 minutes with a 5# pressure loss mini test passed.
1499549524 2017-07-06 Salt Water Injection Well No Violations Inspection revealed that well is currently not in operation due to pump being changed out and swapping out of storage tanks.
1504472582 2010-03-12 Salt Water Injection Well No Violations Well is not in operation for several weeks now.The snow was too high to get back to the well.Now the snow is gone but well is still not in operation.The dike around the storage tanks needs to be repaired and the groundhog holes need to be removed.The tank has had a leak and a repair patch but looks like it may be damp and starting to leak at the bottom.
1505872962 2009-09-17 Salt Water Injection Well No Violations
1509791091 2017-11-03 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation during my inspection.
1512225876 2017-11-28 Salt Water Injection Well No Violations Inspection today indicated that well is currently operating at maximum allowable pressure and I contacted company and requested that they have positive pressure applied to annulus of tubing ASAP.
1523569251 2018-04-11 Salt Water Injection Well No Violations Inspection today revealed that injection pump was not in operation and Producers Services was on site to perform 1500 gallon acid treatment on said well.

Note: According to well owner the well is currently taking 20 barrel of brine per day it appears that formation is possibly plugged up with unknown substance.

1525209861 2018-04-29 Salt Water Injection Well No Violations Inspection today indicated that injection pump was in operation during my inspection,it appears that well is in good general repair at this time.
1526834829 2018-05-20 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that two pen recorder has been installed at well site as requested from a previous inspection.
1549735677 2019-02-07 Salt Water Injection Well No Violations Inspection today revealed that injection pump was not in operation and it was noted that annular pressure has dropped to zero due to fact 2 valve froze and busted ,called company and requested that they change valve and apply positive pressure to annulus of tubing.
1551273648 2019-11-8 0:00: SW No Violations
1555380705 2018-01-29 Salt Water Injection Well No Violations Injection pump was in operation during my inspection.
1600533865 2018-03-25 Salt Water Injection Well No Violations Injection pump not in operation today.
1610120669 2018-07-05 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation and it was noted that a two pen recorder has been installed at wellhead since my last inspection.
1612689934 2010-06-01 Salt Water Injection Well No Violations Dike has been removed on one side so tanks which are leaking can be removed and new tanks put back in. Dike to be repaired after tanks are switched.
1626411604 2018-03-01 Salt Water Injection Well No Violations Inspection today indicated that injection pump was not in operation during my inspection and it was noted that lease road shows that it is in need of repair due too recent flooding in the area.
1626569667 2018-01-24 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection and it was noted that one JHAWK vacuum truck was unloading at the site during my inspection.
1639693811 2010-06-09 Salt Water Injection Well No Violations Tanks have been replaced and dike side rebuilt.
1662293855 2015-02-13 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today and both tanks and well head are properly identified.
1668071416 2014-08-12 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection.
1669898950 2005-03-09 Salt Water Injection Well No Violations
1689775962 2009-07-28 Salt Water Injection Well No Violations Well has not been in operation for a few days.
1734309034 2003-07-10 Salt Water Injection Well No Violations
1743059147 2011-08-03 Salt Water Injection Well No Violations Well does not appear to be in operation . The chart on the well has not been changed and is on 0 since my last inspection.
1764013913 2012-06-15 Salt Water Injection Well No Violations FOLLOW UP TO NOV # -1458088986 I arrived to check this facility and during my inspection I found that a brine spill has occurred just below the pump house. The spill is 10 ft wide for most of the length and almost 110 ft long. The soil is dry now and the vegetation is dead. Someone has mowed the area but no clean up has been started. The operator has not contacted me to advise of any spills. I contacted Bruce Levengood and advised of the spill and issued a verbal notice. I later met with Mike Demantio and scheduled the clean up and a mini test on the annulus for Monday, 6/25/2012.
1770650519 2010-04-30 Salt Water Injection Well No Violations No work done to repair facility , contact operator and found that equipment is ready to come and do repairs now.
1778822177 2012-07-12 Salt Water Injection Well No Violations I arrived today to find that well has been placed back in operation. The 4 1/2 casing which had leaks has been welded to repair the leaks. This well should not be in operation at this time because an integrity test has not been conducted. Call Bruce Levengood and advise he needs this test done before he can operate the well.
1782054425 2012-08-07 Salt Water Injection Well No Violations I am on site today to check on vegetation and to see if work has been started on the vault which is to be installed below the pump house. The well is in operation and there is vegetation established below the pump house but it is still low and will need to be monitored. No work started for the vault.
1782101583 2006-11-02 Salt Water Injection Well No Violations
1797676270 2016-08-09 Salt Water Injection Well No Violations Inspection revealed that well is down for pump replacement and owner is having concrete pad placed in area of new injection pump placement and it will be constructed in a manner that drain line will be plumbed to existing vault.
1814061280 2010-05-14 Salt Water Injection Well No Violations There is equipment on site and tanks have been disconnected to begin repairs.
18476039 2002-3-26 0:00: SW No Violations 1.20
1885637850 2019-03-22 Salt Water Injection Well No Violations Inspection today revealed that injection pump was not in operation during my inspection and it appears that owner is waiting on new transfer to be installed.
1888060693 2017-02-23 Salt Water Injection Well No Violations Inspection today revealed that injection pump was in operation and operating at maximum allowable pressure and I called well owner requesting that they change out two inch valve on annulus side of tubing head it currently is seeping a little apparently the seal system has possibly failed.
1889487608 2004-01-30 Salt Water Injection Well No Violations Well has been idle for a week due to ice and snow conditions.Injection Pressure--20 Annulus pressure---0
1906454793 2016-10-21 Salt Water Injection Well No Violations Inspection today revealed that owner has recently placed concrete floor in pump house and weeds were cut and location was cleaned up, tubing and annular pressure was close will keep eye on pressures well may be equalizing.
1917755047 2013-12-04 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation today and it was noted that annulus pressure has declined and I spoke with company rep and requested that they have positive pressure applied in the near future.
1919004635 2007-08-13 Salt Water Injection Well No Violations
1933868982 2007-07-24 Salt Water Injection Well Violations Noted Found well over pressure .
1936971069 2003-02-12 Salt Water Injection Well No Violations
1945274500 2009-02-26 Salt Water Injection Well No Violations
1954447460 2010-03-31 Salt Water Injection Well No Violations FOLLOW UP TO NOV # 1270209811 During my inspection I found that one of the tanks may be leaking out the bottom. I also found that the dike has a groundhog hole in it. The groundhog and the hole will need removed. The overall height of the dike will need
1961578590 2008-09-08 Salt Water Injection Well No Violations Looks like this well has been shut down.There are weeds and grass growing up and the unloading pad does not look like it has been used for awhile?It also has been blocked off.
197010902 2012-6-15 0:00: SW No Violations 2.00
2008700354 2013-01-04 Salt Water Injection Well No Violations UIC Facility inspection.
2030724151 2011-06-07 Salt Water Injection Well No Violations The chart at the well has not been changed for weeks. It is on -0- and has been for some time. Well does not appear to be in operation.
2034516351 2018-12-07 Salt Water Injection Well No Violations Inspection revealed that injection pump was in operation during my inspection.
2048607482 2004-11-24 Salt Water Injection Well No Violations Well running just over pressure.Call Danny and advise and left Nov inside meter box.
2052823475 2019-6-24 0:00: SW No Violations
2058801309 2012-01-19 Salt Water Injection Well No Violations This well does not appear to be pumping. I did check and the well is on vacuum. The chart has been removed from the recorder at the well. I will need to return the well with a different gauge.
2059292508 2014-06-11 Salt Water Injection Well No Violations Inspection revealed that well is down due too electrical problems in pump house they are currently making repairs to electrical system.
2105666876 2013-10-24 Salt Water Injection Well No Violations Inspection revealed that injection pump was not in operation during my inspection, and it was noted that repairs were being made to injection pump at this time.
2124748633 2010-02-17 Salt Water Injection Well No Violations The well appears to be shut down dew to snow cover.
2127758262 2007-04-10 Salt Water Injection Well No Violations
252819223 2011-3-16 0:00: SW No Violations 1.50
279 2002-8-8 0:00:0 PW No Violations
2875874 SW No Violations 1.00
295625483 2013-3-8 0:00:0 SW No Violations
32076122 2002-7-8 0:00:0 SW No Violations 1.70
354133688 2015-7-30 0:00: SW No Violations
38876007 2002-8-20 0:00: SW No Violations 1.20
390985403 2010-5-10 0:00: SW No Violations 1.50
394087585 2016-2-1 0:00:0 SW No Violations
395037609 2010-4-13 0:00: SW No Violations 1.50
454135625 2017-12-26 0:00 SW No Violations
46476279 2002-10-16 0:00 SW No Violations 1.20
475052711 2006-6-13 0:00: SW No Violations 1.00
47576224 2002-10-29 0:00 SW No Violations
487062907 2012-7-3 0:00:0 SW No Violations 1.50
501019287 2020-2-19 0:00: SW No Violations
553253892 2008-1-9 0:00:0 SW No Violations 1.50
591346252 2010-10-4 0:00: SW No Violations 1.50
652320928 2015-11-25 0:00 SW No Violations
72695184 2013-8-2 0:00:0 SW No Violations
73957209 2007-1-22 0:00: SW No Violations 1.50
7575909 SW No Violations 1.20
780215784 2003-4-14 0:00: SW No Violations 1.20
852878597 2018-9-11 0:00: SW No Violations
859037620 2011-9-22 0:00: SW No Violations 1.50
867805541 2012-10-24 0:00 SW No Violations
869372390 2012-4-17 0:00: SW No Violations 1.50
878868152 2015-10-20 0:00 SW No Violations
979465687 2019-7-26 0:00: SW No Violations
UIC1804 1999-11-3 0:00: SW No Violations
UIC326 1987-9-14 0:00: SW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0591729436 US-OH-126659 2016-04-04 Failure to file salt water injection annual report
0954649468 US-OH-130902 2012-06-28 Failure to monitor pressures/volumes
1270209811 US-OH-107534 2010-04-02 Mechanical failure/contamination
1270209811 US-OH-107535 2010-04-02 Tanks not liquid tight/Improper burial
1458088986 US-OH-113270 2012-06-26 Mechanical failure/contamination
1933868982 US-OH-119462 2007-07-25 Exceeding maximum allowable injection pressure

For data sources see[5]