34-055-21569

Well Details

Well ID: 34-055-21569
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Troy Township
Operator Name: PIN OAK ENERGY PARTNERS LLC
Well Pad ID:
Farm/Lease Name: WELSHFIELD INN UNIT # 1
License Status: Producing
License Date: 1988-08-22
Spud Date: 1988-09-01
Spud Drilling Contractor: [[EPC [EASTERN PETROLEUM]]]
Final Drill Date: 1988-09-10
Well Total Depth: 6820.00 ft
Configuration: Vertical
Latitude: 41.380000
Longitude: -81.130000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1988-08-22 2816 P & S ENERGY INC GeoDate 8/22/88
Oil and Gas 1988-08-22 Issued Date 8/22/88 Expired Date 8/22/89 Acres 0085000 Tool Type RTAF Proposed Formation CLINTON-ROSE Proposed Depth 06820 Proposed Drill Depth 06820
Original Spud 1988-09-01
Completed 1988-09-10
Reached Total Depth 1988-09-10
Completion Report Received 1988-09-21
Construction Permit Expires 1989-08-22
Change of Owner 2019-02-26 Operator changed from 2816, P & S ENERGY INC to 9722, PIN OAK ENERGY PARTNERS LLC
Record Last Modified 2019-02-26

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 4115 4220 0
4115 4220 0
4115 4220 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
0 0 0 FRAC:WATER/SAND/N2

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1989 P & S ENERGY INC 19909.00 640.00 365
1990 P & S ENERGY INC 14121.00 284.00 365
1991 P & S ENERGY INC 9444.00 222.00 365
1992 P & S ENERGY INC 9030.00 128.00 365
1993 P & S ENERGY INC 7891.00 108.00 365
1994 P & S ENERGY INC 6845.00 106.00 365
1995 P & S ENERGY INC 7597.00 97.00 365
1996 P & S ENERGY INC 6112.00 126.00 365
1997 P & S ENERGY INC 5496.00 86.00 365
1998 P & S ENERGY INC 5924.00 0.00 365
1999 P & S ENERGY INC 5129.00 147.00 365
2000 P & S ENERGY INC 4103.00 73.00 365
2001 P & S ENERGY INC 4459.00 73.00 365
2002 P & S ENERGY INC 5030.00 39.00 365
2003 P & S ENERGY INC 3996.00 67.00 365
2004 P & S ENERGY INC 4073.00 53.00 365
2005 P & S ENERGY INC 3303.00 33.00 365
2006 P & S ENERGY INC 3242.00 63.00 365
2007 P & S ENERGY INC 3660.00 118.00 365
2008 P & S ENERGY INC 3571.00 71.00 365
2009 P & S ENERGY INC 4051.00 62.00 365
2010 P & S ENERGY INC 3169.00 30.00 365
2011 P & S ENERGY INC 3847.00 45.00 365
2012 P & S ENERGY INC 3554.00 31.00 366
2013 P & S ENERGY INC 3361.00 39.00 365
2014 P & S ENERGY INC 3242.00 46.00 365
2015 P & S ENERGY INC 3074.00 20.00 365
2016 P & S ENERGY INC 2855.00 0.00 365
2017 P & S ENERGY INC 2579.00 0.00 365
2018 P & S ENERGY INC 2089.00 25.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1989 P & S ENERGY INC Brine 2212 365
1990 P & S ENERGY INC Brine 199 365
1991 P & S ENERGY INC Brine 134 365
1992 P & S ENERGY INC Brine 100 365
1993 P & S ENERGY INC Brine 85 365
1994 P & S ENERGY INC Brine 72 365
1995 P & S ENERGY INC Brine 80 365
1996 P & S ENERGY INC Brine 79 365
1997 P & S ENERGY INC Brine 40 365
1998 P & S ENERGY INC Brine 81 365
1999 P & S ENERGY INC Brine 35 365
2000 P & S ENERGY INC Brine 35 365
2001 P & S ENERGY INC Brine 70 365
2002 P & S ENERGY INC Brine 0 365
2003 P & S ENERGY INC Brine 40 365
2004 P & S ENERGY INC Brine 40 365
2005 P & S ENERGY INC Brine 35 365
2006 P & S ENERGY INC Brine 35 365
2007 P & S ENERGY INC Brine 115 365
2008 P & S ENERGY INC Brine 57 365
2009 P & S ENERGY INC Brine 56 365
2010 P & S ENERGY INC Brine 37 365
2011 P & S ENERGY INC Brine 62 365
2012 P & S ENERGY INC Brine 35 366
2013 P & S ENERGY INC Brine 34 365
2014 P & S ENERGY INC Brine 0 365
2015 P & S ENERGY INC Brine 28 365
2016 P & S ENERGY INC Brine 37 365
2017 P & S ENERGY INC Brine 0 365
2018 P & S ENERGY INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1125383067 2018-2-9 0:00:0 PW No Violations
-67375715 2013-4-29 0:00: PW No Violations
0065990087 2008-09-30 Production Wells No Violations Two ten tank that has exploded and top ring is burnt is still on site. Tank battery is still in violation of general safety. Called company left message, to return call and update status.
0067375715 2013-04-29 Production Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The annulus valve was closed. The well and tank battery are in good repair. The tank battery consists of a 100 BBL production tank, a 35 BBL poly brine tank, and a mechanical separator. The proper identification is located on the tank battery. The lease road is in stable condition. The tank battery and lease road is being shared with permit number 2-1580.
1125383067 2018-02-09 Production Wells No Violations At the time of this inspection, the well was equipped with a plunger lift assembly and the annulus and flow line valves were open. The production records for this well were current. The tank battery consisted of one 100 BBL production tank, one 500 BBL poly brine tank and a mechanical separator. Valves on the separator were open and there was a domestic line with two regulators, a drip bottle and meter, plumbed off of the separator. The tank battery was diked and shared with well 2-1580. Legible signage was located at the well and tank battery, and the lease access was stable. No violations observed.
1220536015 2008-08-29 Production Wells Violations Noted Inspector Lowder advised me of tank battery, and problems in it. Called Jeff Ash from the company approximately 10 days ago, and left a message with Jeff to clean up tank battery. Jeffs called production person is on vacation. Called Jeff 09/04/2008 asked Jeff when he was going to have tank off site. He stated, they were working on getting a person on site to steam clean tank and remove it. I informed Jeff that leaving tank on site is a violation and it needs to be removed. I requested that Jeff have tank offsite by the end of next week, (09/12/2008) 210 Tank in the battery has exploded. The top ring of the tank was burnt, the top of the tank was ten feet behind the separator out of the tank battery. Operator has well 1569 and 1580 producing into one 100 barrel tank. No spill of brine or oil in the tank battery. 210 tank is not causing any environmental danger at this time. Lease road is stable, tank battery ID sign is up. Pictures of tank taken. Violation is 1501:09-9-05 (5) Operations and Maintenance. Exploded and burnt tank needs removed, cannot be stored on site.
1227295563 2008-11-21 Production Wells No Violations 21o tank has been removed. Debris has been removed. Site is snow covered.
1437409680 2015-07-20 Production Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The annulus valve was closed. The well and tank battery are in good repair. The tank battery consists of a 100 BBL production tank, a 35 BBL poly brine tank, and a mechanical separator. The proper identification is located on the tank battery. The lease road is in stable condition. The tank battery and lease road is being shared with permit number 2-1580.
454726807 2019-10-9 0:00: PW No Violations 0.50
65990087 2008-9-30 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1220536015 US-OH-105905 2008-09-04 General Safety

For data sources see[9]

References