If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-163-20318 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.32,"lon":-82.42,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Vinton | |
Municipality: Swan Township | |
Operator Name: ADAMS OIL & GAS LLC | |
Well Pad ID: | |
Farm/Lease Name: S AUSTIN {ERP #1} | |
License Status: Active Injection | |
License Date: 2019-04-25 | |
Spud Date: 1965-08-16 | |
Spud Drilling Contractor: ROSS WELL SERVICE | |
Final Drill Date: 1981-05-21 | |
Well Total Depth: 845.00 ft | |
Configuration: Vertical | |
Latitude: 39.320000 | |
Longitude: -82.420000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1965-08-16 | SHUT DOWN FOR WATER AND SOIL ANALYSIS AND REMEDIATION. CONVERT TO SDRW 7-16-75, R.I. 11-3-76, RE-ISSUE 1-21-76 |
Completed | 1965-09-17 | SHUT DOWN FOR WATER AND SOIL ANALYSIS AND REMEDIATION. CONVERT TO SDRW 7-16-75, R.I. 11-3-76, RE-ISSUE 1-21-76 |
Reached Total Depth | 1981-05-21 | SHUT DOWN FOR WATER AND SOIL ANALYSIS AND REMEDIATION. CONVERT TO SDRW 7-16-75, R.I. 11-3-76, RE-ISSUE 1-21-76 |
Completion Report Received | 1981-10-26 | SHUT DOWN FOR WATER AND SOIL ANALYSIS AND REMEDIATION. CONVERT TO SDRW 7-16-75, R.I. 11-3-76, RE-ISSUE 1-21-76 |
CO | 1985-04-12 | 1728 OIL FIELD CONSTRUCTION IN |
CO | 1996-08-05 | 5459 PIKE PETROLEUM INC GeoDate |
Annulus Pressure Monitoring Approved | 1998-04-13 | SHUT DOWN FOR WATER AND SOIL ANALYSIS AND REMEDIATION. CONVERT TO SDRW 7-16-75, R.I. 11-3-76, RE-ISSUE 1-21-76 |
Last Compliance Report | 2000-04-11 | SHUT DOWN FOR WATER AND SOIL ANALYSIS AND REMEDIATION. CONVERT TO SDRW 7-16-75, R.I. 11-3-76, RE-ISSUE 1-21-76 |
Change of Owner | 2006-04-14 | Operator changed from 5459, PIKE PETROLEUM INC to 7851, ADAMS OIL & GAS |
APP | 2019-04-25 | Proposed Formations:BEREA SAND, Issued Date:4/25/2019, Expired Date:4/24/2021 12:00:00 PM, Drilling unit acres:170, Proposed Well Type:OG, Proposed Well Class: |
Record Last Modified | 2019-05-02 | SHUT DOWN FOR WATER AND SOIL ANALYSIS AND REMEDIATION. CONVERT TO SDRW 7-16-75, R.I. 11-3-76, RE-ISSUE 1-21-76 |
Construction Permit Expires | 2021-04-24 | SHUT DOWN FOR WATER AND SOIL ANALYSIS AND REMEDIATION. CONVERT TO SDRW 7-16-75, R.I. 11-3-76, RE-ISSUE 1-21-76 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2000-04-11 | 820 | 865 | 0 |
820 | 865 | 0 | |
820 | 865 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
0 | 0 | 0 | 500 GALS FE ACID | |||
H2O | 0 | 450 Bbl | 3500 |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1057691101 | 2017-7-19 0:00: | SW | No Violations | 0.50 |
-1058049147 | 2012-2-7 0:00:0 | ER | No Violations | |
-116846303 | 2019-5-1 0:00:0 | ER | No Violations | 1.50 |
-1178657 | 2020-4-2 0:00:0 | ER | No Violations | 1.50 |
-1228523624 | 2004-5-24 0:00: | ER | No Violations | |
-1271345052 | 2013-1-15 0:00: | ER | No Violations | 2.50 |
-1325486019 | 2008-2-25 0:00: | ER | No Violations | |
-1350544812 | 2009-4-7 0:00:0 | ER | No Violations | |
-1465409721 | 2008-9-11 0:00: | ER | No Violations | |
-1568589864 | 2013-1-15 0:00: | ER | No Violations | 2.00 |
-1694160718 | 2016-8-1 0:00:0 | AM | No Violations | 1.50 |
-1719310720 | 2009-9-1 0:00:0 | ER | No Violations | |
-1851787812 | 2011-1-5 0:00:0 | ER | No Violations | 1.50 |
-190186403 | 2018-10-29 0:00 | ER | No Violations | 1.00 |
-2050973044 | 2016-10-28 0:00 | ER | No Violations | 2.00 |
-2081918514 | 2004-4-12 0:00: | OR | No Violations | |
-224088442 | 2016-6-15 0:00: | ER | No Violations | 0.70 |
-375170677 | 2004-1-29 0:00: | ER | No Violations | |
-452102597 | 2009-6-12 0:00: | ER | No Violations | |
-473630839 | 2020-2-6 0:00:0 | ER | No Violations | 3.00 |
-5293354 | 2008-12-23 0:00 | ER | No Violations | |
-609848609 | 2009-12-11 0:00 | ER | No Violations | |
-671344262 | 2013-8-12 0:00: | ER | No Violations | 3.00 |
-807144004 | 2019-10-31 0:00 | ER | No Violations | 2.00 |
-825804352 | 2008-6-11 0:00: | ER | No Violations | |
-861525785 | 2008-11-12 0:00 | ER | No Violations | |
-864657824 | 2017-3-20 0:00: | ER | No Violations | 2.00 |
-927961076 | 2017-5-12 0:00: | ER | No Violations | 3.00 |
-92966440 | 2012-2-7 0:00:0 | ER | No Violations | 1.50 |
0000UIC329 | 1987-03-13 | Enhanced Recovery Project | No Violations | ACTION CH.ORD 1501:9-3-07 (E)(F) DELINQUENT QTLY RPT. |
0000UIC705 | 1989-06-13 | Enhanced Recovery Project | No Violations | ACTION CH.ORD 1501:9-5-10 (E) Delinquent Qtly Rpt. |
0000UIC993 | 1990-10-12 | Enhanced Recovery Project | No Violations | ACTION CH.ORD 1501:9-3-07 E MONTHLY VOLUMES -TL |
0000UIC994 | 1990-10-12 | Enhanced Recovery Project | No Violations | ACTION CH.ORD 1501:9-3-07 F MONITOR ANNULAR -TL |
0005293354 | 2008-12-23 | Enhanced Recovery Project | No Violations | A follow-up inspection revealed compliance. Identification is displayed at the well and the storage tanks. However, the identification does not contain a lease name and Mountaineer Gas Transmission is listed as the owner. At the time of the inspection, RBDMS showed that Adams Oil & Gas is still the owner of this well. The previous inspection (mini-test) showed positive pressure on the annulus. During the inspection, a ball valve could not be opened therefore, the pressure was not obtained. |
001269i473 | 2001-10-31 | Enhanced Recovery Project | No Violations | Follow - up on NOV , Non - Compliance, no action to replace valve , rewrite ID at tanks , or make well capable of injecting. |
001269i744 | 2002-02-06 | Enhanced Recovery Project | No Violations | Follow-up on NOV, Non-Compliance, no action to comply with NOV or Chiefs Order. Also dike standing full of fresh water at this time. |
005609i102 | 2001-03-22 | Enhanced Recovery Project | No Violations | Follow - up on NOV , Non - Complaince , company has not put ID at well and or storage tanks , and put a 1/4 valve on the well for inspection. |
0092966440 | 2012-02-07 | Enhanced Recovery Project | No Violations | Accompanied Inspector Jon Scott on an inspection of this well and tank battery. Updated photos were taken. |
0109853924 | 2014-04-07 | Salt Water Injection Well | No Violations | Compliance notice follow-up. The well consists of 2-210 barrel tanks, injection well and 3- 100 barrel tanks. Nothing has been done to bring the well into compliance. |
0115189686 | 2012-08-02 | Enhanced Recovery Project | No Violations | No change since last inspection. Accompanied by inspector Morgan Button. |
0145744486 | 2014-07-03 | Enhanced Recovery Project | No Violations | Chiefs Order follow up inspection. Inspected the containment dike, tanks, unloading pad, annulus pressure and injection pressure. The injection tubing is open with no master valve. Annulus has zero pressure. Site is overgrown with vegetation. Containment dike is full of water with aquatic vegetation and fish. The well is not connected to injection equipment and is not capable of injection. No identification is posted on the location. |
0156472717 | 2002-11-25 | Production Wells | No Violations | An inspection of the well revealed that the well is idle and incapable of injecting brine at this time, MIT test has not been done, production lines and pump not hooked up to well. No ID at the well or tanks. |
0190186403 | 2018-10-29 | Enhanced Recovery Project | No Violations | Chiefs Order # 2011-50 follow up inspection. The injection tubing is open with no master valve installed. The annulus has zero pressure. No identification is posted on location. The containment dike is full of water and aquatic vegetation. The well is not equipped with an injection pump or injection line. |
0224088442 | 2016-06-15 | Enhanced Recovery Project | No Violations | Chiefs Order # 2011-50 follow up inspection. The injection tubing is open with no master valve. The annulus has zero pressure. Well site is overgrown with vegetation. A boat and trailer have been placed between the containment dike and the well. The containment dike is full of water and aquatic vegetation. The access road is being used frequently, based on the tracks. No identification was posted. |
0293309190 | 2018-05-04 | Enhanced Recovery Project | Violations Noted | Our records indicate that the Division has not received the 2017 Enhanced Recovery Well Annual Report (Form 204) that was due to the Division by April 15, 2018. Please submit the requested report by June 4, 2018. |
0375170677 | 2004-01-29 | Enhanced Recovery Project | No Violations | Well is idle, unable to locate company, may need to turn over to I & O section for plugging. |
0379016273 | 2011-03-31 | Enhanced Recovery Project | No Violations | FOLLOW UP TO NOV # 1340532399 FOLLOW UP TO NOV # 1556115216 Injection well is disconnected from injection lines. No pump equipment on site. Tank dike is full of water. Remove water from dike. Annulus has zero pressure. Annulus must be tested to maximum injection pressure of 562 psi for 15 minutes with no more than 5% loss. Well in not capable of injection. Well must be capable of injection or plugged 1509-22 (J). Schedule mechanical integrity test with Inspector Jon Scott 740-624-4963. |
0452102597 | 2009-06-12 | Enhanced Recovery Project | No Violations | An inspection revealed that the status remains unchanged. No injection at this time. The tanks are not connected to the well and valves are closed. The pump does not contain a belt. 2 black plastic from 210 bbl tank to pump (inlet) and 2 steel from pump to well (outlet) found disconnected at well. ID found not incomplete as, well owner name, emergency#, well name and ERP# were not observed. 6 of freshwater with aquatic life observed in dike. A 1 x 6 trench cut out along backside of dike for drainage. (2) 210 bbl tanks are corroding, but unable to tell if leaking due to fluid inside dike. The ID at tank location contains only correct owner name and emergency contact#.. The dike height is from 6 to 7. The liner contains approximately 5 tears along the top backside of dike. The tears range from 6 to 2. Positive pressure was observed on annulus. |
0536365566 | 2006-07-19 | Enhanced Recovery Project | No Violations | Brent Bear will issue NOV. |
0575326649 | 2003-07-28 | Enhanced Recovery Project | No Violations | Follow - up on Chiefs Order, well still idle and incapable of injecting brine. No action seen to comply with NOV or Chiefs Order. |
0579330070 | 2013-09-12 | Enhanced Recovery Project | No Violations | Injection tubing is open with no valve. Dike is full of water and vegetation. Annulus has zero pressure. Identification is on the ground. The access road to the well has been mowed. There has been no efforts made to equip the well for injection. Accompanied by Inspector Kip Thompson. |
0584060068 | 2016-08-09 | Enhanced Recovery Project | No Violations | Chief Order # 2011-50 Follow up inspection. The injection tubing is open with no master valve installed. The well is not connected to an injection line or injection equipment. The containment dike has two 210 barrel tanks. The containment dike is full of water and aquatic vegetation. No identification posted at the well or facility. |
0609848609 | 2009-12-11 | Enhanced Recovery Project | No Violations | An inspection revealed positive pressure on the annular side of the well. As previously noted, the well status remains the same. The observed identification at tanks and well is not complete and the surface facility not connected for injection. |
0671344262 | 2013-08-12 | Enhanced Recovery Project | No Violations | Chiefs Order follow-up inspection. There has been no changes to the well or surface facility since the last inspection. Wellhead has been turned 3/4 of a turn. Injection tubing master valve and cross with two valves has been removed from the well. Annulus pressure gauge is damaged. Identification is on the ground at the well. There was no pressure on the annulus. Injection tubing is open with no valve. Containment dike is full of water. Site is over grown with vegetation. There are two steel tanks in the dike. Photos were taken. |
0745432480 | 2011-03-31 | Enhanced Recovery Project | No Violations | FOLLOW UP TO NOV # 1556115216 Injection well is disconnected from injection lines. No pump equipment on site. Tank dike is full of water. Remove water from dike. Annulus has zero pressure. Annulus must be tested to maximum injection pressure of 562 psi for 15 minutes with no more than 5% loss. Well in not capable of injection. Well must be capable of injection or plugged 1509-22 (J). Schedule mechanical integrity test with Inspector Jon Scott 740-624-4963. |
0768658068 | 2018-11-01 | Salt Water Injection Well | No Violations | The salt water injection well remains unchanged in the status. The tubing is open to the atmosphere. The containment dike is full of water. This inspection is a follow up to Chiefs Order # 2011-50. |
0825804352 | 2008-06-11 | Enhanced Recovery Project | No Violations | A follow-up inspection revealed non-compliance. No action has been taken to resolve violations. |
0850924201 | 2018-09-11 | Enhanced Recovery Project | No Violations | Chiefs Order # 2011-50 follow up inspection. The injection tubing is open with no master valve installed. No identification posted. The annulus has zero pressure. The containment dike has two 210 barrel steel tanks and the dike is full of water. |
0861525785 | 2008-11-12 | Enhanced Recovery Project | No Violations | A mini-test revealed 3 psi loss after 15 minutes. The well passed the required test. |
0864657824 | 2017-03-20 | Enhanced Recovery Project | No Violations | Chief Order # 2011-50 Follow up Inspection. The containment dike is full of fluid. The injection tubing is open with no master valve. The annulus has zero pressure. The unloading pad has debris piled on it. The access road has evidence of vehicle use recently. |
0898472921 | 2018-05-02 | Enhanced Recovery Project | No Violations | Chiefs Order # 2011-50 follow up inspection. The injection tubing is open with no master valve installed. There is zero pressure on the annulus. The containment dike is full of fluid and aquodic vegetation. No identification is posted. The pump house has been removed. The concrete slab is all that remains. |
0927961076 | 2017-05-12 | Enhanced Recovery Project | No Violations | Chiefs Order # 2011-50 follow up inspection. The injection tubing is open with no master valve installed. There is zero pressure on the annulus. The containment dike is full of fluid and aquodic vegetation. No identification is posted. |
1030713964 | 2009-03-03 | Enhanced Recovery Project | No Violations | An inspection revealed that the injection side of the well will need to be equipped with a 1/4 valve. The annulus pressure was not obtained, due to a valve that was stuck. The dike is full of fluid and will need to be pumped. The identification still shows the wrong owner. The well owner has been instructed to correct deficiencies. |
1045495259 | 2013-09-12 | Salt Water Injection Well | No Violations | I accompanied Jon Scott on the inspection of this well. There is a Chiefs order that has not be satisfied. The well is idle and in disrepair. The dike has 18 of water in it. There was no pressure on the annulus. |
1057691101 | 2017-07-19 | Salt Water Injection Well | No Violations | My inspection revealed the well to be idle. The tubing is open to the atmosphere. There was 0 pressure on the annulus. The dike if full of water and aquatic vegetation. The well lacks legible identification. |
1058049147 | 2012-02-07 | Enhanced Recovery Project | No Violations | Enhanced recovery injection well is not connected to injection lines or equipment. Annulus has zero pressure. Injection tubing has zero pressure. Tank dike is full of water. Photos were taken of enhanced recovery injection well, tanks and dike. |
1074672290 | 2017-05-15 | Enhanced Recovery Project | Violations Noted | Our records indicate that the Division has not received the Enhanced Recovery Annual Report (Form 204) that was due on April 15th for 2016, despite a letter that was sent April 28, 2017 with a deadline of May 12, 2017 to submit the reports requested. please submit the requested Forms to the Division by 5/26/2017. |
1085405554 | 2004-05-24 | Enhanced Recovery Project | Violations Noted | Reviewing records at the Vinton Co Courthouse, show the well has been assigned to Team RM, Inc.,2178 Castle Crest Dr., Worthington, Ohio |
109853924 | 2014-4-7 0:00:0 | SW | No Violations | 1.00 |
1101136015 | 2004-08-16 | Enhanced Recovery Project | No Violations | Follow-up on NOV, Non-Compliance, well still idle. |
115189686 | 2012-8-2 0:00:0 | ER | No Violations | 1.00 |
1154308579 | 2006-07-19 | Enhanced Recovery Project | Violations Noted | An inspection was conducted at the facility owned by Adams Oil & Gas on 7/19/2006. During the inspection, it was noted that there was no pressure at the injection or annulus side of the well. A mini test will be required. The dike needs repaired. The unloading pad also needs to be repaired because, it is cracking. No identification at the wellhead or at the storage tanks. |
1175752455 | 2006-09-13 | Enhanced Recovery Project | No Violations | A follow-up inspection was conducted on 9/13/2006. During the inspection, it was noted that the previously noted violations have not been resolved. The company was contacted by telephone on 9/13/2006 and informed that the violations still exist. |
1184016292 | 2007-07-05 | Enhanced Recovery Project | No Violations | A follow-up inspection revealed non-compliance. No action has been taken to resolve the violations. Mr. Jamie Adams states that the well ownership issue has not been resolved. Also stating that they have not been working around the Vinton County area because of this issue. |
1213795798 | 2008-06-11 | Enhanced Recovery Project | Violations Noted | An inspection revealed that Adams Oil & Gas has failed to comply with previously noted violations. Positive pressure is still needed on the annulus side of the well. A mini-test has not been performed and will be required. The unloading pad needs repaired, due to the concrete that is cracking. No identification was observed at the well and storage tanks. A new NOV will be reissued to the company. |
1218503252 | 2008-07-29 | Enhanced Recovery Project | No Violations | A follow-up inspection revealed non-compliance. No action has been taken to resolve violations. Request Chiefs Order. |
1228523624 | 2004-05-24 | Enhanced Recovery Project | Violations Noted | FOLLOW UP TO NOV # 1085405554 Reviewing records at the Vinton Co Courthouse, show the well has been assigned to Team RM, Inc.,2178 Castle Crest Dr., Worthington, Ohio |
1269i473 | 2001-10-31 0:00 | ER | No Violations | |
1269i744 | 2002-2-6 0:00:0 | ER | No Violations | |
1270671724 | 2010-03-15 | Enhanced Recovery Project | No Violations | An inspection revealed non-compliance. The well status remains unchanged since the last inspection. No injection at this time. The dike contains fresh water and the fluid level will need to be addressed for capacity. The identification sign at well and storage tank location remains incomplete. |
1271345052 | 2013-01-15 | Enhanced Recovery Project | No Violations | Enhanced recovery injection well is not connected to injection lines or equipment. Annulus has zero pressure. Injection tubing has zero pressure. Tank dike is full of water. Photos were taken of enhanced recovery injection well, tanks and dike. Accompanied by Andy Thomas MRI 2. |
1297365034 | 2011-02-10 | Salt Water Injection Well | No Violations | Upon arrival it was noted by myself and Rob Stonerock that there was no pump equipment in the building adjacent to the tank battery. As we walked up to the tank battery, we noted several rips in the liner. There is a pipe that sticks out toward the building that has been cut. Containment area is filled with water up to about 1 foot from the top of the dike. Proper identification was noted on the well head. There are no lines going to/from well head to tank battery. |
1311805454 | 2011-07-27 | Enhanced Recovery Project | No Violations | CN follow up. Injection well is disconnected from injection lines. No pump on site. Tank dike is full of water. Well is not capable of injection. No change from last inspection. |
1318606918 | 2019-11-13 0:00 | ER | No Violations | 2.00 |
1323187361 | 2011-12-05 | Enhanced Recovery Project | No Violations | Follow up inspection for Compliance notice No. 1556115216 issued 4-6-2011. Annulus has zero pressure. Well is disconnected from injection lines. No pump equipment is on location. Dike is full of water. Identification is upside down on ground at well head. Well is not capable of injection. Photos were taken during inspection. |
1325486019 | 2008-02-25 | Enhanced Recovery Project | No Violations | A follow-up inspection revealed non-compliance. |
1330533828 | 2012-01-20 | Enhanced Recovery Project | No Violations | Enhanced recovery injection well is not connected to injection lines or equipment. Annulus has zero pressure. Injection tubing has zero pressure. Tank dike is full of water. Photos were taken of enhanced recovery injection well, tanks and dike. |
1340532399 | 2011-03-31 | Enhanced Recovery Project | No Violations | FOLLOW UP TO NOV # 1556115216 Injection well is disconnected from injection lines. No pump equipment on site. Tank dike is full of water. Remove water from dike. Annulus has zero pressure. Annulus must be tested to maximum injection pressure of 562 psi for 15 minutes with no more than 5% loss. Well in not capable of injection. Well must be capable of injection or plugged 1509-22 (J). Schedule mechanical integrity test with Inspector Jon Scott 740-624-4963. |
1350544812 | 2009-04-07 | Enhanced Recovery Project | No Violations | A follow-up inspection revealed that a 1/4 valve has been placed on the injection side of the well. The valve for the annulus has been repaired and will now open. No pressure was observed on the annulus and injection side of the well. At the time of the inspection, the dike still contained fluid with no observed leaks. A section along the side of this dike contains a trench and will need to be repaired. The company has been instructed of this deficiency to include the liner that contains small tears along the top. The identification at both the well and tank battery locations have been painted over incorrect well owner, Mountaineer Gas Transmission. Adams Oil & Gas and ERP # will need to be added to the ID. |
1374086774 | 2013-07-17 | Enhanced Recovery Project | No Violations | Chiefs Order follow-up inspection. Wellhead has been turned 3/4 of a turn. Injection tubing master valve and cross with two valves has been removed from the well. Annulus pressure gauge is damaged. Identification is on the ground at the well. There was no pressure on the annulus. Injection tubing is open with no valve. Containment dike is full of water. Site is over grown with vegetation. There are two steel tanks in the dike. Photos were taken. |
1374234955 | 2019-8-29 0:00: | ER | No Violations | 2.50 |
1384957488 | 2013-11-19 | Enhanced Recovery Project | No Violations | Injection tubing is open with no valve. Dike is full of water and vegetation. Annulus has zero pressure. Identification is on the ground. There has been no efforts made to equip the well for injection. |
1411580388 | 2014-09-24 | Enhanced Recovery Project | No Violations | Chiefs Order follow up inspection. Inspected the containment dike, tanks, unloading pad, annulus pressure and injection pressure. The injection tubing is open with no master valve. Annulus has zero pressure. Site is overgrown with vegetation. Containment dike is full of water with aquatic vegetation and fish. A skim coating of oil is on 25% of the surface area of the water. The well is not connected to injection equipment and is not capable of injection. No identification is posted on the location. |
1426801030 | 2015-03-19 | Enhanced Recovery Project | No Violations | Chiefs Order follow up inspection. Inspected the containment dike, tanks, unloading pad, annulus pressure and injection pressure. The injection tubing is open with no master valve. Annulus has zero pressure. Site is overgrown with vegetation. There has been recent activity near the well, small trees have been cut down and branches are all around the well site. The containment dike is full of water with aquatic vegetation. There were no visible signs of the crude oil (in the containment dike) that was observed during the previous inspection. The well is not connected to injection equipment and is not capable of injection. No identification is posted on the location. |
1446041875 | 2015-10-27 | Enhanced Recovery Project | No Violations | Chiefs Order # 2011-50 follow up inspection. The injection tubing is open with no master valve. The annulus has zero pressure. The containment dike is full of water and aquatic vegetation. The unloading pad has a pile of scrap metal that is approximately 3 tall and covers the entire pad. A refrigerator and water heater have been added to the pile on the unloading pad, since the last inspection. The access road is being used frequently, based on the tracks. The access road has been mowed and off road vehicle trails have been developed extending away from the facility. No identification was posted. |
145744486 | 2014-7-3 0:00:0 | ER | No Violations | 2.00 |
1457634022 | 2016-03-09 | Enhanced Recovery Project | No Violations | Chiefs Order # 2011-50 follow up inspection. The injection tubing is open with no master valve. The annulus has zero pressure. The containment dike is full of water and aquatic vegetation. The unloading pad has a pile of scrap metal that is approximately 3 tall and covers the entire pad. The access road is being used frequently, based on the tracks. No identification was posted. |
1465409721 | 2008-09-11 | Enhanced Recovery Project | No Violations | A follow-up inspection revealed non-compliance. No action has been taken to resolve violations. The injection side of the well will require a 1/4 fitting that will allow for a gauge to be installed. The valve was opened and no vacuum or pressure was observed. At the time of this inspection, a valve located on the annular side of the well could not be opened. Therefore, the pressure was not obtained. The meter connected to this well has been removed. No identification was observed at the well and storage tanks. A trench cut in the side of the dike will need to be repaired. The liner contains small tears at locations along the top of the dike. |
1547147966 | 2019-01-10 | Enhanced Recovery Project | No Violations | Chiefs Order # 2011-50 follow up inspection. The injection tubing is open with no master valve installed. The annulus has zero pressure. No identification is posted on location. The containment dike is full of water and aquatic vegetation. The well is not equipped with an injection pump or injection line. |
1549013258 | 2015-06-10 | Enhanced Recovery Project | No Violations | Chiefs Order 2011-50 follow up inspection. Inspected the containment dike, tanks, unloading pad, annulus pressure and injection pressure. The injection tubing is open with no master valve. Annulus has zero pressure. Well site is overgrown with vegetation. There has been recent activity near the well, the access road and an area near the unloading pad have been mowed recently. The containment dike is full of water with aquatic vegetation. The well is not connected to injection equipment and is not capable of injection. No identification is posted on the location. |
1556115216 | 2011-03-31 | Enhanced Recovery Project | Violations Noted | Injection well is disconnected from injection lines. No pump equipment on site. Tank dike is full of water. Remove water from dike. Annulus has zero pressure. Annulus must be tested to maximum injection pressure of 562 psi for 15 minutes with no more than 5% loss. Well in not capable of injection. Well must be capable of injection or plugged 1509-22 (J). Schedule mechanical integrity test with Inspector Jon Scott 740-624-4963. |
1564108278 | 2002-11-25 | Enhanced Recovery Project | No Violations | An inspection of the well revealed that the well is idle and incapable of injecting brine at this time, MIT test has not been done, production lines and pump not hooked up to well. No ID at the well or tanks. |
156472717 | 2002-11-25 0:00 | PW | No Violations | |
1568589864 | 2013-01-15 | Enhanced Recovery Project | No Violations | Accompanied Inspector Jon Scott on this inspection. No attempts have been made by company to gain compliance. Well head is disconnected from lines. Annulus and injection pressures are 0. Containment dike is full of water. Spoke with the caretakers of the property, and gave them my card to give to the land owner. |
1575558207 | 2019-11-19 0:00 | ER | No Violations | 4.20 |
1694160718 | 2016-08-01 | Administrative Inspection | No Violations | Compliance notice follow-up. The well consists of a well head with tubing that is open to atmosphere, 2-210 barrel tanks. The tanks are in a containment dike that is full of water and aquatic vegetation. No change in the status of the well. New pictures were taken. |
1719310720 | 2009-09-01 | Enhanced Recovery Project | No Violations | A follow-up inspection was conducted with Mr. Jeff Fry, West Region Oil & Gas Supervisor and UIC Field Supervisor. It was noted that the well status remains the same. |
1725113274 | 2010-07-08 | Enhanced Recovery Project | No Violations | An inspection revealed that the identification has been corrected. The well status remains the same. No injection at this time. |
1832032079 | 2003-05-08 | Enhanced Recovery Project | No Violations | Follow-up on Chiefs Order, Non-Compliance, well still idle and not injecting at this time, hung a copy of the Chiefs Order on the well and storage tanks. |
1834641563 | 2007-11-05 | Enhanced Recovery Project | No Violations | A follow-up inspection revealed that violations have not been resolved. No action has been taken to bring the EOR well into compliance. The injection side of the well does not contain 1/4 inch fitting which would allow placement of gauge. Annulus side of the well does not contain pressure. A mini-test is required. No identification observed. Dike is full and needs pumped. |
1851787812 | 2011-01-05 | Enhanced Recovery Project | No Violations | An inspection revealed identification has now been corrected at the well. No injection at this time. The motor and injection lines from inside the shed have been removed. |
1971103219 | 2015-09-15 | Enhanced Recovery Project | No Violations | The injection tubing is open with no master valve. The annulus has zero pressure. The containment dike is full of water and aquatic vegetation. The unloading pad has a pile of scrap metal that is approximately 3 tall and covers the entire pad. The access road has been mowed and off road vehicle trails have been developed extending away from the facility. No identification was posted. |
1983300544 | 2018-07-19 | Salt Water Injection Well | No Violations | My inspection revealed the well is idle. The tubing is open to the atmosphere. There was 0 pressure on the annulus. The dike if full of water and aquatic vegetation. The well lacks legible identification. New coordinates were taken during my inspection. I called Mr. Doug Adams at 10:00 AM today and left him a voicemail message. Mr. Adams returned my call at 10:58 PM and stated the case was in front of a Vinton County Ohio judge waiting on a judgement. |
2050973044 | 2016-10-28 | Enhanced Recovery Project | No Violations | Chiefs Order # 2011-50 follow up inspection. The injection tubing is not equipped with a master valve and is open. The annulus has zero pressure. The well is not connected to injection equipment. The containment dike is full of fluid. Pictures were taken of the well and location. No identification posted. |
2051542214 | 2004-11-17 | Enhanced Recovery Project | No Violations | Follow-up on NOV, Non-Compliance, well still idle and incapable of producing. |
2081918514 | 2004-04-12 | Orphan | No Violations | An inspection of the well revealed well is incapable of producing, will start a I & O file on well. |
2124728484 | 2014-05-13 | Enhanced Recovery Project | No Violations | Injection tubing is open with no master valve. Dike is full of water and vegetation. Annulus has zero pressure. No identification. There has been no efforts made to equip the well for injection. (no injection lines or injection filters, pumps). |
293309190 | 2018-5-4 0:00:0 | ER | No Violations | |
379016273 | 2011-3-31 0:00: | ER | No Violations | |
536365566 | 2006-7-19 0:00: | ER | No Violations | |
5609i102 | 2001-3-22 0:00: | ER | No Violations | |
575326649 | 2003-7-28 0:00: | ER | No Violations | |
579330070 | 2013-9-12 0:00: | ER | No Violations | 2.00 |
584060068 | 2016-8-9 0:00:0 | ER | No Violations | 2.50 |
745432480 | 2011-3-31 0:00: | ER | No Violations | |
768658068 | 2018-11-1 0:00: | SW | No Violations | |
850924201 | 2018-9-11 0:00: | ER | No Violations | 0.80 |
898472921 | 2018-5-2 0:00:0 | ER | No Violations | 2.50 |
iTOMK00011 | 2001-02-15 | Enhanced Recovery Project | No Violations | 1501:9-5-09 (A)(3) AND 1501:9-9-05 (A)(10) |
iTOMK000112 | 2001-2-15 0:00: | ER | No Violations | |
UIC329 | 1987-3-13 0:00: | ER | No Violations | |
UIC705 | 1989-6-13 0:00: | ER | No Violations | |
UIC993 | 1990-10-12 0:00 | ER | No Violations | |
UIC994 | 1990-10-12 0:00 | ER | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0293309190 | US-OH-123055 | 2018-08-03 | Failure to file enhanced recovery annual report | |
1074672290 | US-OH-101578 | 2017-07-23 | Failure to file enhanced recovery annual report | |
1085405554 | US-OH-101953 | 2004-05-24 | Well incapable of inj./production | |
1154308579 | US-OH-104024 | 2006-07-30 | Failure to monitor annulus pressure | |
1154308579 | US-OH-104025 | 2006-07-30 | Insufficient/No identification | |
1154308579 | US-OH-104026 | 2006-07-30 | Dike or pit not able to prevent escape of brine or other wastes | |
1154308579 | US-OH-104027 | 2006-07-30 | Failure to pass required test | |
1213795798 | US-OH-105608 | 2008-06-18 | Failure to plug | |
1213795798 | US-OH-105609 | 2008-06-18 | Insufficient/No identification | |
1228523624 | US-OH-106165 | 2004-05-24 | Well incapable of inj./production | |
1556115216 | US-OH-115149 | 2011-04-06 | Failure to monitor annulus pressure | |
1556115216 | US-OH-115150 | 2011-04-06 | Well incapable of inj./production | |
1556115216 | US-OH-115151 | 2011-04-06 | No SPCC dike/or failure to keep dike free of water or oil |