34-163-20353

Well Details

Well ID: 34-163-20353
Loading map...
Country: United States
State: Ohio
County: Vinton
Municipality: Madison Township
Operator Name: SLC ENERGY LTD
Well Pad ID:
Farm/Lease Name: MCGLAUGHLIN
License Status: Producing
License Date: 2009-08-10
Spud Date: 1969-03-01
Spud Drilling Contractor:
Final Drill Date: 1969-06-01
Well Total Depth: 1150.00 ft
Configuration: Vertical
Latitude: 39.280000
Longitude: -82.380000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1969-03-01
Completed 1969-06-01
Reached Total Depth 1969-06-01
CO 1987-02-10 566 GRIM PAUL A
Change of Owner 2001-11-21 Operator changed from 566, GRIM PAUL A to 5755, CHIEFTAIN ENERGY CORP.
APP 2009-08-10 Proposed Formations:BEREA, Issued Date:8/10/2009, Expired Date:8/10/2010 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
Construction Permit Expires 2010-08-10
Change of Owner 2011-04-21 Operator changed from 5755, CHIEFTAIN ENERGY CORP to 6227, HOUGHTON INVESTMENTS, L.L.C.
Change of Owner 2015-05-14 Operator changed from 6227, HOUGHTON INVESTMENTS, L.L.C. to 9440, SLC ENERGY LTD
Record Last Modified 2015-05-14

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 300 Bbl 3000

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 ISON PROD SERVICES INC 0.00 0.00 30
2002 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2003 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2005 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2006 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2007 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2008 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2009 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2010 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2011 HOCKING HILLS ENERGY AND WELL 0.00 0.00 0
2012 HOUGHTON INVESTMENTS LLC 0.00 0.00 366
2013 HOUGHTON INVESTMENTS LLC 0.00 0.00 365
2014 HOUGHTON INVESTMENTS LLC 0.00 0.00 365

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 ISON PROD SERVICES INC Brine 0 30
2002 HOCKING HILLS ENERGY AND WELL Brine 0 0
2003 HOCKING HILLS ENERGY AND WELL Brine 0 0
2005 HOCKING HILLS ENERGY AND WELL Brine 0 0
2006 HOCKING HILLS ENERGY AND WELL Brine 0 0
2007 HOCKING HILLS ENERGY AND WELL Brine 0 0
2008 HOCKING HILLS ENERGY AND WELL Brine 0 0
2009 HOCKING HILLS ENERGY AND WELL Brine 0 0
2010 HOCKING HILLS ENERGY AND WELL Brine 0 0
2011 HOCKING HILLS ENERGY AND WELL Brine 0
2012 HOUGHTON INVESTMENTS LLC Brine 0 366
2013 HOUGHTON INVESTMENTS LLC Brine 0 365
2014 HOUGHTON INVESTMENTS LLC Brine 0 365

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1509643335 2019-3-14 0:00: PW No Violations 0.20
-190399912 2011-1-26 0:00: PW No Violations 1.00
-2001256362 2017-11-9 0:00: PW No Violations 1.50
-2106106665 2008-12-15 0:00 PW No Violations
-2126334706 2018-11-1 0:00: PW No Violations 0.30
-396512138 2010-8-9 0:00:0 PW No Violations
-655173553 2011-1-18 0:00: PW No Violations
-710127634 2018-7-19 0:00: PW No Violations 0.20
0006077393 2009-10-16 Production Wells No Violations A follow-up inspection to Notice of Violation and Compliance Agreement Schedule was conducted with Mr. Robert Stonerock, South Region Oil & Gas Supervisor. The inspection revealed non-compliance. Plugging permits have been received for both McGlaughlin wells (Permit No. 352 & 353).
0190399912 2011-01-26 Production Wells No Violations A NOMSV follow-up inspection revealed compliance. Identification has now been placed at the well. However, the well remains idle and does not meet the minimum requirement for commercial production. The Notice of Violation will remain unresolved.
0332528720 2008-12-15 Production Wells Violations Noted A complaint was received alleging non-production. An inspection revealed that the well is idle and not capable of production. The well contains a pump jack with no weights or motor. The bridle is split and the polish rod is bent. A tree has fallen onto the pump jack. Brush has grown around the well and the electric box is lying on the ground. Unable to obtain GPS reading at time of the inspection. No identification observed at either the tanks or the well. Plug or produce this well. Provide identification.
0396512138 2010-08-09 Production Wells No Violations A follow-up inspection to Notice of Violation, Compliance Schedule Agreement (7/14/2009) and NOMSV revealed non-compliance. No observed identification at the well or tank. As previously noted during 3/10/2010, the pumping unit has been removed from the well and location. Enforcement Action will be requested.
0655173553 2011-01-18 Production Wells No Violations A follow-up inspection revealed non-compliance.
0710127634 2018-07-19 Production Wells No Violations My inspection revealed the well is not in compliance. There has been no attempt to bring the well into compliance. The well consists of conductor casing with 4.5 inch diameter casing inside the conductor casing. The 4.5 inch diameter casing has tubing. The tubing has a valve attached to the end of the tubing and the valve is turned off. The well is not connected to any production equipment. The well is not capable of production. I do not have a phone number that works for well owner Mr. Ron Coleman.
1145859841 2008-12-15 Production Wells No Violations FOLLOW UP TO NOV # -2106106665 FOLLOW UP TO NOV # 332528720 A complaint was received alleging non-production. An inspection revealed that the well is idle and not capable of production. The well contains a pump jack with no weights or motor. The bridle is split and the polish rod is bent. A tree has fallen on
1331655625 2019-01-09 Production Wells No Violations My inspection revealed this well remains in violation of being incapable of production. There has been no change in the status of the well since my last inspection on 7.19.18. The well is not connected to any production equipment. I have no way to contact well owner SLC Energy regarding the violation associated with this well.
1509643335 2019-03-14 Production Wells No Violations My inspection revealed this wells status has not changed since my last inspection on 1.09.19. The well was cited for 1509:12(B) well shall be plugged on 11.08.17. The owner of the well has made no attempt to bring this well into compliance.
1569823095 2018-03-08 Production Wells No Violations My inspection revealed the well is not in compliance. There has been no attempt to bring the well into compliance. The well consists of conductor casing with 4.5 inch diameter casing inside the conductor casing. The 4.5 inch diameter casing has tubing. The tubing has a valve attached to the end of the tubing and the valve is turned off. The well is not connected to any production equipment. The well is not capable of production. New pictures were taken during my inspection.
1588008883 2020-4-27 0:00: PW No Violations 1.00
1597560291 2010-03-17 Production Wells No Violations A follow-up inspection revealed non-compliance. The well remains idle with no observed identification at the well or tank battery. Chieftain Energy has failed to comply with NOV, Compliance Agreement Schedule and NOMSV. The pumping unit has now been removed from the well. New photographs were obtained from this inspection.
1600392364 2017-11-08 Production Wells Violations Noted My inspection revealed the well is idle and incapable of production. The well consists of conductor casing with 4.5 inch diameter casing. There is tubing inside the 4.5 inch diameter casing and the tubing has a valve on the end of it. The valve was turned off. The wellhead is not connected to any production lines. New pictures were taken during my inspection.The well owner SLC Energy shall submit a written plugging schedule to Kip Thompson at 5880 Memory Road Zanesville, Ohio 43701 within 15 days, and plug the well within 30 days. The well owner/operator will be notified if the plugging schedule is approved or denied.
1708469636 2009-10-29 Production Wells No Violations A follow-up inspection to Notice of Violation and Compliance Agreement Schedule revealed non-compliance. Plugging permits have been received for both McGlaughlin wells (Permit No. 352 & 353). The well status remains unchanged. The well is equipped with a pumping unit with no weights, motor or electric. The belts were observed to be dry rotted. The valve on casing side of well was observed closed and attached section of plasic cut. Bridle and horse set at angle. No well head for surface casing. No identification observed at well or tanks (shared tank battery). The 2 steel line from pumping tee side of well was observed rotted near location containing (1) 100 bbl upright and (1) on side. At this location 2 plastic would have tied into steel and traveled to (1) 100 bbl with knockout approx 30 away. No connections to knockout. Another 2 line observed at the (2) 100 bbl tank locations (not connected here) and kinked before entering the (1) 100 bbl with knockout. Will talk with management regarding further action.
2001256362 2017-11-09 Production Wells No Violations On the day of this inspection, I found an idle oil and gas well equipped with 4.5 inch diameter casing with 1.5 inch tubing with a ball valve connected at the top of the tubing. The ball valve is closed and is exposed at the top of the wellhead. There is a stack of tubing and rods beside the wellhead with no production equipment onsite. Oil and gas well is not capable of production. Identification is hanging on a tree branch over top of the wellhead and is legible.
2093982313 2009-04-30 Production Wells No Violations A follow-up inspection revealed non-compliance. No action has been taken to resolve violations. No identification. The well contains a pumping unit and no house gas. Steel line from pumping tee routed through the woods found rotted around a section and found connected to 1 plastic line. No lines were observed connected to the tank.
2106106665 2008-12-15 Production Wells No Violations FOLLOW UP TO NOV # 332528720 A complaint was received alleging non-production. An inspection revealed that the well is idle and not capable of production. The well contains a pump jack with no weights or motor. The bridle is split and the polish rod is bent. A tree has fallen on
2126334706 2018-11-01 Production Wells No Violations My inspection revealed the status of the well remains unchanged since my last inspection on 7.19.18. The well consists of a wellhead with tubing. There is a valve attached to the top of the tubing that was in the closed position. I have no way to contact the owner of the well.
332528720 2008-12-15 0:00 PW No Violations
6077393 2009-10-16 0:00 PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0332528720 US-OH-123488 2009-01-06 Failure to legibly identify well
0332528720 US-OH-123489 2009-01-06 Well shall be plugged
1600392364 US-OH-115687 2017-11-21 NONE Well shall be plugged

For data sources see[8]