{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.53,"lon":-82.99,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Pickaway | |
Municipality: Pickaway Township | |
Operator Name: OHIO ENERGY ASSETS, INC. | |
Well Pad ID: | |
Farm/Lease Name: GIFFORD O | |
License Status: Final Restoration | |
License Date: 2008-09-22 | |
Spud Date: 1994-08-12 | |
Spud Drilling Contractor: KILBARGER DRLG | |
Final Drill Date: 1994-08-15 | |
Well Total Depth: 2550.00 ft | |
Configuration: Vertical | |
Latitude: 39.530000 | |
Longitude: -82.990000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1994-08-10 | 1987 DUBLIN ENERGY CORP. GeoDate 8/10/94 |
Oil and Gas | 1994-08-10 | Issued Date 8/10/94 Expired Date 8/10/95 Acres 0020000 Tool Type RTAF Proposed Formation TRENTON THRU KNOX Proposed Depth 02550 Proposed Drill Depth 02550 |
Original Spud | 1994-08-12 | CHG FM 9-3-94 |
Completed | 1994-08-15 | CHG FM 9-3-94 |
Reached Total Depth | 1994-08-15 | CHG FM 9-3-94 |
Plugged Back | 1994-08-24 | CHG FM 9-3-94 |
Completion Report Received | 1994-11-04 | CHG FM 9-3-94 |
Change of Owner | 2002-05-08 | Operator changed from 1987, EXPLORE ENERGY CORP. to 6091, OHIO ENERGY ASSETS, INC. |
APP | 2008-09-22 | Proposed Formations:ROSE RUN & TRENTON, Issued Date:9/22/2008, Expired Date:9/22/2009 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class: |
Plugged/Abandoned | 2009-02-18 | CHG FM 9-3-94 |
Construction Permit Expires | 2009-09-22 | CHG FM 9-3-94 |
Record Last Modified | 2017-02-15 | CHG FM 9-3-94 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 2080 | 2414 | 0 |
2080 | 2414 | 0 | |
2080 | 2414 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
ACID | 0 | 1000 Gal | 0 | ACIDIZED W/1000 GAL |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1997 | OHIO PRODUCTION CORP | 0.00 | 68.00 | 60 |
1998 | OHIO ENERGY ASSETS, INC. | 0.00 | 0.00 | 0 |
1999 | OHIO ENERGY ASSETS, INC. | 0.00 | 0.00 | 0 |
2000 | OHIO ENERGY ASSETS, INC. | 0.00 | 0.00 | 0 |
2002 | OHIO ENERGY ASSETS, INC. | 0.00 | 27.00 | 30 |
2003 | OHIO ENERGY ASSETS, INC. | 0.00 | 41.00 | 14 |
2004 | OHIO ENERGY ASSETS, INC. | 0.00 | 28.00 | 2 |
2005 | OHIO ENERGY ASSETS, INC. | 0.00 | 49.00 | 5 |
2006 | OHIO ENERGY ASSETS, INC. | 0.00 | 0.00 | 0 |
2007 | OHIO ENERGY ASSETS, INC. | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1997 | OHIO PRODUCTION CORP | Brine | 0 | 60 |
1998 | OHIO ENERGY ASSETS, INC. | Brine | 0 | 0 |
1999 | OHIO ENERGY ASSETS, INC. | Brine | 0 | 0 |
2000 | OHIO ENERGY ASSETS, INC. | Brine | 0 | 0 |
2002 | OHIO ENERGY ASSETS, INC. | Brine | 0 | 30 |
2003 | OHIO ENERGY ASSETS, INC. | Brine | 0 | 14 |
2004 | OHIO ENERGY ASSETS, INC. | Brine | 0 | 2 |
2005 | OHIO ENERGY ASSETS, INC. | Brine | 0 | 5 |
2006 | OHIO ENERGY ASSETS, INC. | Brine | 0 | 0 |
2007 | OHIO ENERGY ASSETS, INC. | Brine | 60 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1824922712 | 2005-4-5 0:00:0 | PW | No Violations | |
-2001223978 | 2009-2-17 0:00: | PB | No Violations | |
-348656241 | 2004-3-10 0:00: | PW | No Violations | |
-570099790 | 2006-1-10 0:00: | PW | No Violations | |
0008274005 | 2001-09-20 | Production Wells | No Violations | FOLLOW-UP REVEALED OWNER HAS FAILED TO MAKE THE WELL CAPABLE OF PRODUCTION. (NO MOTOR ON THE PUMPING UNIT.) WEATHER: MOSTLY SUNNNY AND 71 DEGREES. |
001248i127 | 2001-11-20 | Production Wells | Violations Noted | Weather Conditions: Mostly sunny & 35 degrees. Follow-up revealed well is still idle. |
001248i227 | 2002-02-19 | Production Wells | Violations Noted | WEATHER CONDITIONS: Cloudy and 45 degrees. FOLLOW-UP revealed some one has been to the well. (there are ruts leading to the well.) There is still no motor on the pumping unit. The valve on the flow line is in the closed position and the valve on the tubing is in the open position. (see photos) Owner has failed to place the well into production as required by NOV. |
0081298894 | 2004-10-14 | Production Wells | No Violations | Motor removed from pump unit, valve open. Well area clean.
Tank area clean and dike free of water. |
0277653943 | 2009-03-31 | Final Restoration | No Violations | - Operator has removed tanks and graded tank area, this area has vegetation starting to grow. Well area graded and vegetating growing.
- Photos taken. |
0348656241 | 2004-03-10 | Production Wells | No Violations | - Inspection of well, Pump unit has no motor, all valves are in the close position
- Tank area clean 1 -100 barrel tank and 1 small plastic tank no fluids noted in tanks at this time. |
0570099790 | 2006-01-10 | Production Wells | No Violations | - Well incapable of production, no motor on pump unit. Valves open on well.
- ID on tanks - Weather light rain temp 30s |
0739062824 | 2008-04-08 | Production Wells | No Violations | No motor on pump unit, valves open on 2 in production line at well head. ID on tank |
1035898317 | 2002-10-29 | Production Wells | Violations Noted | Follow-up revealed no motor on pumping unit. All valves on the well head are closed. Incorrect ID posted at the storage tank. I took three (3) photos this date. WEATHER CONDITIONS: Cloudy, rain, and 40 degrees. |
1041862206 | 2003-01-06 | Production Wells | Violations Noted | Follow-up revealed no motor on the pump jack. No change of owner posted at the storage tank and / or well head. I took three ( 3 ) photos. Owner has failed to file production recorders for year 2001. Owner had until January 4, 2003 to have the well in production and / plugged. WEATHER CONDITIONS: Two ( 2) inch snow cover and 30 degrees. 01-07-2003 At 9:30 A.M. Nancy Milleville called and advised me that she had sent a letter to the Chief advising him that the well is being produced and enclosed a run ticket. I asked her to send me a copy of that letter. I also advised her to put up the proper ID. Inspector will conduct a follow-up after I have received the information. |
1042550927 | 2003-01-14 | Production Wells | No Violations | Pump jack on well head
No motor on pump jack, All valves are closed Tanks are empty, operator request temporary abandonment. |
1042572288 | 2003-01-14 | Production Wells | No Violations | On 01-13-3 I received a copy of a letter from Ohio Energy Assets, Inc. ( Nancy Melville ) dated 10-22-2002 advising the Chief that the well has been produced and attached a run ticket. Inspection this date revealed ID posted on the storage tank. ID violation corrected. WEATHER CONDITIONS: Cloudy, snow and 23 degrees. |
1066762599 | 2003-10-21 | Production Wells | No Violations | - On site for inspection tank and dike in good shape.
- Pump jack unable to operate no motor, valve open on 2 inch production line. |
1068061325 | 2003-10-28 | Production Wells | No Violations | Follow up inspection, joint inspection with Jeff Fry.
- Operator has pump up well in the last week since last inspection. - No motor on pump jack - Tank and dike in good shape. |
1168370877 | 2007-01-09 | Production Wells | No Violations | - No motor on pump unit, operator uses temporary motor on pump unit. Operator produce well in December 2006.
- ID on tank, small oil spill at tank. Well valve open on production lines. |
1210i11573 | 2002-04-02 | Production Wells | No Violations | Well has pump jack, no motor. Valves shut, not capable of production. Took 2 digital photos. |
1210i1157379 | 2002-4-2 0:00:0 | PW | No Violations | |
1210i14511 | 2001-03-23 | Production Wells | No Violations | Tank battery has 1 100 Bbl. Steel tank which is empty and a plastic brine tank that is approx. 1/3 full. Pump jack has motor missing.Well is incapable of production at this time.Chiefs order requested, by Inspector White. |
1210i1451177 | 2001-3-23 0:00: | PW | No Violations | |
1210i96505 | Production Wells | No Violations | Follow-up with Inspector White revealed no change in the wells status. There is no motor on the pumping unit but there is approximately ten (10) pounds of pressure on the flow line gauge. | |
1210i9650595 | PW | No Violations | ||
1235149737 | 2009-02-18 | Plug / Plug Back | No Violations | - Berry Well Service Rig, finish running tubing into well to a depth of 2150. Well blocked off at 2150 and wasnt able to wash out blockage.
- Formation Cement Co. cemented well. 1st plug was a 400 foot plug that will cover the Trenton and Black River formation. Gel spacer placed between next plug. 2nd plug at base of surface casing and 3rd plug 100 feet to surface. - All casing was cut below surface and metal ID plate placed on well. Photo of ID plate. |
1248i127 | 2001-11-20 0:00 | PW | No Violations | |
1248i227 | 2002-2-19 0:00: | PW | No Violations | |
1442349601 | 2004-10-14 | Preliminary Restoration | No Violations | Preliminary inspection done by previous inspector, on paper report.
Well is a production well. |
1824922712 | 2005-04-05 | Production Wells | No Violations | No motor on pump unit, valve open. Tank area clean.
Weather sunny temp. low 70s |
2001223978 | 2009-02-17 | Plug / Plug Back | No Violations | - On site, Berry Well Service Rig 2 rigged up over well. Pulled 2,269 feet of 2 3/8 8rd tubing from well. Several attempts were made to release packer but unsuccessful. Rip 4 1/2 casing at 2,200 feet, tally for 4 1/2 2,186 feet. Run tubing back into well, but hit some blockage. Stop for the day. |
277653943 | 2009-3-31 0:00: | FR | No Violations | |
739062824 | 2008-4-8 0:00:0 | PW | No Violations | |
81298894 | 2004-10-14 0:00 | PW | No Violations | |
8274005 | 2001-9-20 0:00: | PW | No Violations | 1.50 |
iTOMK00003 | 2000-05-05 | Production Wells | Violations Noted | |
iTOMK000037 | 2000-5-5 0:00:0 | PW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
001248i127 | US-OH-106637 | 2001-11-20 | Well shall be plugged | |
001248i227 | US-OH-106642 | 2002-02-19 | Well shall be plugged | |
1035898317 | US-OH-100352 | 2002-10-29 | Failure to legibly identify well | |
1041862206 | US-OH-100619 | 2003-01-06 | Failure to legibly identify well | |
1041862206 | US-OH-100620 | 2003-01-06 | Well shall be plugged | |
iTOMK00003 | US-OH-131591 | Failure to legibly identify well |