X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-129-20201

Well Details

Well ID: 34-129-20201
Loading map...
Country: United States
State: Ohio
County: Pickaway
Municipality: Washington Township
Operator Name: HOUGHTON INVESTMENTS LLC
Well Pad ID:
Farm/Lease Name: BOLENDER
License Status: Final Restoration
License Date: 2003-10-14
Spud Date: 2003-11-04
Spud Drilling Contractor: FMS DRILLING
Final Drill Date: 2003-11-09
Well Total Depth: 2884.00 ft
Configuration: Vertical
Latitude: 39.580000
Longitude: -82.880000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2003-10-14 6227 HOUGHTON INVESTMENTS, L.L.C. Proposed Formation ROSE RUN/TREMPEALEAU Issued Date 10/14/2003 Expired Date 10/13/2004 6:00:00 AM
Inspector Comments Cement Job 2003-11-03 Good water and cement circulation.Cement Ticket Notes Inspector Reporting MITCHELL MICHAEL
Original Spud 2003-11-04 DRY PER WCR..UNOFFICIAL PLUG DATE: 11-9-03
Completed 2003-11-09 DRY PER WCR..UNOFFICIAL PLUG DATE: 11-9-03
Plugged/Abandoned 2003-11-09 DRY PER WCR..UNOFFICIAL PLUG DATE: 11-9-03
Reached Total Depth 2003-11-09 DRY PER WCR..UNOFFICIAL PLUG DATE: 11-9-03
Completion Report Received 2003-11-21 DRY PER WCR..UNOFFICIAL PLUG DATE: 11-9-03
Construction Permit Expires 2004-10-13 DRY PER WCR..UNOFFICIAL PLUG DATE: 11-9-03
Record Last Modified 2013-03-14 DRY PER WCR..UNOFFICIAL PLUG DATE: 11-9-03

For data sources see[2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-2137156289 2004-7-29 0:00: FR No Violations
1072185467 2003-12-09 Preliminary Restoration No Violations Joint inspection with Jeff Fry ODNR and Tom, Dave, Bill Atha owner of permit. At previous inspection notice air bubbles in water covering plug well. Jeff baled water from hole air coming from outside of surface casing. Jeff recommended to place PVC pipe in hole before covering well with topsoil, so gas could vent in the air, and it would mark well location for the farmer when working in the field.
1081861860 2004-04-13 Final Restoration No Violations - Operator has filled in all pits graded and seeded area. Operator has also place small PVC pipe in ground to mark where well was drilled to vent small gas leak from outside of casing, as requested by Supervisor Jeff Fry.
2137156289 2004-07-29 Final Restoration No Violations Operator has completed final restoration. Operator has an approved landowner waiver to seed or establish vegetation. PVC pipe is still in place as request to vent gas, no gas noted at inspection. Joint inspection with Jeff Fry.

For data sources see[3]

References