X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-163-20536

Well Details

Well ID: 34-163-20536
Loading map...
Country: United States
State: Ohio
County: Vinton
Municipality: Madison Township
Operator Name: ADAMS OIL & GAS LLC
Well Pad ID:
Farm/Lease Name: BENEDICT INC
License Status: Producing
License Date: 1981-11-19
Spud Date: 1981-11-20
Spud Drilling Contractor:
Final Drill Date: 1981-11-29
Well Total Depth: 1092.00 ft
Configuration: Vertical
Latitude: 39.270000
Longitude: -82.400000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1981-11-19 1728 OIL FIELD CONSTRUCTION IN GeoDate 11/19/81
Original Spud 1981-11-20 INSPECTION OF 3/18/04 REVEALED 4 1/2" CASING WITH TUBING AND RODS, NO PUMP JACK. TWO 100 Bbl TANKS AND SEPARATOR. I&O CASE # 2004 08 044. RI & CH IN OWNER 11-19-81, LOGGING CONTRACTOR=PLAINS
Completed 1981-11-29 INSPECTION OF 3/18/04 REVEALED 4 1/2" CASING WITH TUBING AND RODS, NO PUMP JACK. TWO 100 Bbl TANKS AND SEPARATOR. I&O CASE # 2004 08 044. RI & CH IN OWNER 11-19-81, LOGGING CONTRACTOR=PLAINS
Reached Total Depth 1981-11-29 INSPECTION OF 3/18/04 REVEALED 4 1/2" CASING WITH TUBING AND RODS, NO PUMP JACK. TWO 100 Bbl TANKS AND SEPARATOR. I&O CASE # 2004 08 044. RI & CH IN OWNER 11-19-81, LOGGING CONTRACTOR=PLAINS
CO 1996-08-05 5459 PIKE PETROLEUM INC GeoDate 11/19/81
Change of Owner 2006-04-14 Operator changed from 5459, PIKE PETROLEUM INC to 7851, ADAMS OIL & GAS
Record Last Modified 2019-04-03 INSPECTION OF 3/18/04 REVEALED 4 1/2" CASING WITH TUBING AND RODS, NO PUMP JACK. TWO 100 Bbl TANKS AND SEPARATOR. I&O CASE # 2004 08 044. RI & CH IN OWNER 11-19-81, LOGGING CONTRACTOR=PLAINS

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 982 988 12
2006-09-11 1050 1052 24
982 988 12
982 988 12
2006-09-11 1070 1074 28

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 300 Bbl 40000

For data sources see[4]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1273922418 2007-3-1 0:00:0 PW No Violations
-1606367522 2004-3-18 0:00: OR No Violations
-488664976 2018-12-5 0:00: PW No Violations 0.70
-547041323 2007-7-5 0:00:0 PW No Violations
-59715680 2008-12-10 0:00 PW No Violations
-923437122 2019-3-25 0:00: PW No Violations 0.30
0059715680 2008-12-10 Production Wells No Violations An inspection was conducted with Mr. Doug Adams, Adams Oil & Gas. The well status has not changed since the previous inspection.
0156372716 2002-11-25 Production Wells No Violations An inspection of the well revealed the well to be idle and incapable of producing, well has tubing and rods in well, not pump jack, production lines parted at tank battery.
0324275432 2015-12-23 Production Wells No Violations I found this well to be idle. The well contained tubing and rods with no pumping unit. The stone base and the timbers were still in place for the pumping unit however it wasnt there. There were no leadlines hooked up to the well. Rubbish was found near the well head. The tank battery consisted of 2 100 barrel tanks. Pictures were taken.
0488664976 2018-12-05 Production Wells No Violations My inspection revealed this well consisted of a wellhead with tubing and rods. The tubing valves were in the closed position. The casing valves were in the closed position. There was evidence of a pumping unit associated with this well, but there was no pumping unit at the time of my inspection. The well was disconnected from any production lines. The well is incapable of production because the well is not connected to any production lines. The tank battery consisted of 2-100 barrel tanks and a vertical separator. The well lacked a legible identification. The owner of the well shall place a legible identification at the well or at the tank battery. The well is currently incapable of production. The well owner, ADAMS OIL & GAS LLC shall submit a written plugging schedule to Kip Thompson at 5880 Memory Road, Zanesville Ohio 43701 within 30 days, per ORC 1509:13(B)(7), and plug the well within 180 days. The well owner/operator will be notified if the plugging schedule is approved or denied.
0547041323 2007-07-05 Production Wells No Violations A follow-up inspection revealed non-compliance. The well is still incapable of production. There is no pump jack and the production line is not connected to the tank battery. The landowner is not receiving house gas. No action has been taken to resolve the violations. Mr. Jamie Adams states that the well ownership issue has not been resolved. Also stating that they have not been working around the Vinton County area because of this issue.
0788737877 2004-01-29 Production Wells No Violations Well is idle, unable to locate company, may need to turn over to I & O section for plugging.
0923437122 2019-03-25 Production Wells No Violations My inspection revealed this wells status remains unchanged since my last inspection on 12.5.18. On this date the well was in violation of 1501:9-9-05(A)10, failure to legibly identify the well and 1509:12(B), well shall be plugged.
1273922418 2007-03-01 Production Wells Violations Noted An inspection revealed that this well is idle and not capable of production. Adams Oil & Gas, has presented a production plan to Mr. Joe Hoerst.
1506262028 2020-4-2 0:00:0 PW No Violations 0.50
156372716 2002-11-25 0:00 PW No Violations
1606367522 2004-03-18 Orphan No Violations An inspection of the well revealed the well still idle and incapable of producing, took photos for I & O case.
1623116264 2008-11-26 Production Wells No Violations An inspection revealed that this well is still idle and has not been placed back into production. The well owner, Mr. Doug Adams, had received notice that well(s) will need to be placed into production and require identification. Mr. Adams has previously stated that wells lack production due to the infrastructure relating to gas transmission. The well contains only rods and tubing. The valves were found to be closed with no flowline connected. Identification was not found at either the well or tank battery. A GPS reading was obtained for the well and the tank battery locations.
1774800917 2007-12-26 Production Wells No Violations A follow-up inspection revealed non-compliance. Tubing and rods observed in the well. No sales meter, identification or pump jack on-site.
324275432 2015-12-23 0:00 PW No Violations 2.50
788737877 2004-1-29 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1273922418 US-OH-107612 2007-03-14 Failure to legibly identify well
1273922418 US-OH-107613 2007-03-14 Well shall be plugged

For data sources see[5]

References