X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-081-20727

Well Details

Well ID: 34-081-20727
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: ASCENT RESOURCES UTICA LLC
Well Pad ID: US-OH-001489
Farm/Lease Name: HAMMACK W CRC JF
License Status: Producing
License Date: 2017-08-25
Spud Date: 2017-08-08
Spud Drilling Contractor: PIONEER DRILLING
Final Drill Date: 2017-10-15
Well Total Depth: 18080.00 ft
Configuration: Horizontal
Latitude: 40.340000
Longitude: -80.670000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2017-08-01 Proposed Formations:UTICA THROUGH POINT PLEASANT, Issued Date:8/1/2017, Expired Date:8/1/2019 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:ST, Proposed Well Class:STRT
APP 2017-08-25 Proposed Formations:UTICA THROUGH POINT PLEASANT, Issued Date:8/25/2017, Expired Date:8/25/2019 12:00:00 PM, Drilling unit acres:190.679, Proposed Well Type:OG, Proposed Well Class:NWC
Reached Total Depth 2017-10-15
Correction to Well 2017-12-29 UPDATE TARGET/TAKE PER AS-DRILLED PLAT.
Construction Permit Expires 2018-08-25
Completion Report Received 2018-09-11
Record Last Modified 2018-09-13

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2018-09-12 10161 10302 0
2018-09-12 17811 17913 0
17811 17913 0
10161 10302 0
10161 10302 0

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 03/22/2018 04/09/2018 9823 14,806,600.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 MICROSCOUT Halliburton Concentrate Listed Below Listed Below 0 0 0
MICROSCOUT PLUS Halliburton Concentrate Listed Below Listed Below 0 0 0
MC B-8614 Halliburton Biocide Listed Below Listed Below 0 0 0
FE-2A Halliburton Additive Listed Below Listed Below 0 0 0
GEL 1100 Mountain Supply and Service LLC Gelling Agent Listed Below Listed Below 0 0 0
LCA-1 Halliburton Solvent Listed Below Listed Below 0 0 0
LP-70 Halliburton Scale Inhibitor Listed Below Listed Below 0 0 0
FR-76 Halliburton Friction Reducer Listed Below Listed Below 0 0 0
SAND-PREMIUM WHITE-40/70, BULK Halliburton Proppant Listed Below Listed Below 0 0 0
HAI-OS ACID INHIBITOR Halliburton Corrosion Inhibitor Listed Below Listed Below 0 0 0
Crystalline silica, quartz 14808-60-7 100 11.2144 15,577,600.0
Glutaraldehyde 111-30-8 30 0.0143969 20000
Quaternary ammonium compounds,

benzyl-C12-16-alkyldimethyl chlorides

68424-85-1 5 0.00112478 1563
Acrylamide acrylate copolymer Proprietary 30 0.0157559 21887
Modified thiourea polymer Proprietary 30 0.000217648 303
Iron oxide 1309-37-1 0.1 0.000469274 653
Ethoxylated alcohols Proprietary 30 0.000217648 303
Phosphoric acid 7664-38-2 0.1 0.00002250 32
Polylactide resin Proprietary 1 0.00469274 6519
Titanium dioxide 13463-67-7 0.1 0.000469274 653
Methanol 67-56-1 60 0.000543272 757
Fatty acids, tall oil Proprietary 30 0.000217648 303
Ethanol 64-17-5 1 0.000224956 313
Polymer Not assigned 68 0.00023155 322
Citric acid 77-92-9 60 0.00303415 4215
Aluminum oxide 1344-28-1 1 0.00469274 6519
Ethylene Glycol 107-21-1 60 0.0144193 20030
Neutralized Polyacrylic Emulsion Proprietary 10 0.00240321 3339
Olefins Proprietary 5 0.00008706 124
Inorganic salt Proprietary 30 0.0157559 21887
Potassium chloride 7447-40-7 10 0.0469274 65186
Hydrotreated light petroleum distillate 64742-47-8 30 0.0157559 21887
PH Buffer 8055-55-8 15 0.00005108 71
Sodium sulfate 7757-82-6 0.1 0.00000000 1
Sodium persulfate 7775-27-1 100 0.00000072 1
Emulsifier 9002-92-0 10 0.00003405 48
Hydrochloric acid 7647-01-0 7.5 0.015023 20867.4
Hdrotreated light petrolem distillates Proprietary 100 0.000504942 702
Propargyl alcohol 107-19-7 10 0.00007255 101
Polysccharide Proprietary 1 0.0029555 4106
SAND-COMMON WHITE-100 MESH, SSA-2, BULK (100003676) Halliburton Proppant Listed Below Listed Below 0 0 0
SP BREAKER Halliburton Breaker Listed Below Listed Below 0 0 0
Fresh Water Operator Base Fluid Water 7732-18-5 100 88.7925 123,339,000.0
Ingredients Listed Above Listed Above Water 7732-18-5 100 0.586048 814066
HYDROCHLORIC ACID Halliburton Solvent Listed Below Listed Below 0 0 0

For data sources see[4]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2018-04-08 H2O 8 342270 Gal 373041 Halliburton STAGE 44/44

STAGES 2-43 SEE IMAGES

2018-03-22 H2O 8 344672 Gal 299965 Halliburton STAGE 1/44

STAGES 2-43 SEE IMAGES

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2018 ASCENT RESOURCES UTICA LLC 3585723 0 183
2019 ASCENT RESOURCES UTICA LLC 710441 0 90

For data sources see[6] [7]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2018 ASCENT RESOURCES UTICA LLC Brine 22604 183
2019 ASCENT RESOURCES UTICA LLC Brine 1629 90

For data sources see[8] [9]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1403650906 2019-7-22 0:00: UL No Violations 1.00
-1788903268 2017-8-8 0:00:0 CS No Violations 6.50
-644661707 2020-1-15 0:00: PW No Violations 1.00
0521684697 2017-12-13 Completion Testing No Violations On the date of my inspection I found a well maintained access road with a locked gate. The pad is surrounded by a fenced earthen dike covered by healthy vegetation. There are 4 recently drilled wells on the pad surrounded by metal fences. The wells have not been hydraulically fractured yet. Production equipment on the pad includes, 4 sand separators, 4 gas production units, and two 500 barrel tanks within a metal dike. The production equipment is surrounded by concrete barriers. There is a garbage roll off container being stored on the pad near the lease road entrance.
1502463719 2017-08-04 Drill / Deepen / Reopen No Violations On the date of my inspection I found Precision Drilling rigged up and ready to begin spudding this well. They are currently waiting on the permit to be issued. Once they receive the permit, they will begin digging the cellar then drill the conductor to approximately 110 feet. They will set a basket at approximately 50 feet due to an expected mine void at 60 feet. There are currently 3 other wells with set surface casing on this pad.
1506669205 2017-09-29 Casing String Witnessed No Violations I am on site to witness the cementing of 13.375 inch surface casing. Pioneer Drilling rig 77 drilled a 17.5 inch diameter hole to a depth of approximately 1423 feet and set 1422 feet of 13.375 inch 61 pound per foot casing. O-Tex established circulation with fresh water, pumped 35 barrels of gel ahead, then pumped 1470 sacks of class H cement, 1.2 yield and 15.6 pound per gallon, Surface Set. O-Tex displaced with 210 barrels of fresh water. Approximately 60 barrels of cement returned to surface. The wiper plug landed and pressure was increased to approximately 500 pounds per square inch (psi) over pump pressure, the casing held approximately 1050 psi for 5 minutes.
1507641719 2017-10-10 Drill / Deepen / Reopen No Violations On the date of my inspection I found Pioneer rig 77 drilling the production section of this well at approximately 14200 feet. Ascent expects to reach the total depth for this well on 10/12/17. They did not encounter any hydrogen sulfide gas while drilling into the Utica formation like they did on a previous well on this pad. During my inspection I found multiple tears and punctures in the containment near the chemical storage area. The company man indicated that the repair crew was scheduled to come out this afternoon. All of the chemicals were within containment. The pad is surrounded by a fenced earthen dike covered by healthy vegetation. The pad drain valves are in the closed position and do not appear to be leaking.
1788903268 2017-08-08 Casing String Witnessed No Violations I am on site today to witness the cementing of 30 inch conductor casing. Precision Drilling drilled a 36 inch diameter hole to a depth of 110 feet and ran 110 feet of 30 inch diameter 118 pound per foot conductor casing. C & J Energy Services pumped 441 sacks of class A cement, 1.18 yield, 15.6 pounds per gallon with 2 percent Calcium Chloride and 0.25 pound per sack flow seal. C & J then displaced with 83 barrels of water, leaving 10 feet of cement in the casing. A cement basket was ran at approximately 54 feet in case the predicted void at 60 feet opened up during the cement job. Good cement returned to surface and remained static. Approximately 4 barrels of cement returned to surface but fell back approximately 1 foot. Ascent will have Precision top out the cellar with grout prior to drilling the mouse hole.
521684697 2017-12-13 0:00 CT No Violations 0.50

For data sources see[10]

References