X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-117-23825

Well Details

Well ID: 34-117-23825
Loading map...
Country: United States
State: Ohio
County: Morrow
Municipality: Perry Township
Operator Name: BECK RICHARD E
Well Pad ID:
Farm/Lease Name: BECK
License Status: Domestic Well
License Date: 1988-01-21
Spud Date: 1988-03-15
Spud Drilling Contractor: CO TOOLS
Final Drill Date: 1988-05-01
Well Total Depth: 3985.00 ft
Configuration: Vertical
Latitude: 40.570000
Longitude: -82.680000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1988-01-21 Issued Date 1/21/88 Expired Date 1/20/89 Acres 0020000 Tool Type CT Proposed Formation TREMPEALEAU Proposed Depth 03895 Proposed Drill Depth 03895
Original Spud 1988-03-15 Alternate address for Richard Beck: 803 Commanche Trail, Fort Myers, FL 33931 11/2/17 wb
Completed 1988-05-01 Alternate address for Richard Beck: 803 Commanche Trail, Fort Myers, FL 33931 11/2/17 wb
Reached Total Depth 1988-05-01 Alternate address for Richard Beck: 803 Commanche Trail, Fort Myers, FL 33931 11/2/17 wb
CO 1988-06-27 1987 DUBLIN ENERGY CORP. GeoDate 1/21/88
Completion Report Received 1988-07-12 Alternate address for Richard Beck: 803 Commanche Trail, Fort Myers, FL 33931 11/2/17 wb
Construction Permit Expires 1989-01-20 Alternate address for Richard Beck: 803 Commanche Trail, Fort Myers, FL 33931 11/2/17 wb
Change of Owner 2011-01-03 WELL WAS TRANSFERRED FROM EXPLORE ENERGY CORP (# 1987) TO MR. RICHARD BECK ON DEC. 4, 1995. NOT RECORDED IN RBDMS. CORRECTION TO OWNERSHIP MADE 01/03/2011.
Record Last Modified 2017-11-02 Alternate address for Richard Beck: 803 Commanche Trail, Fort Myers, FL 33931 11/2/17 wb

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 1504 1585 40
1504 1585 40
1504 1585 40

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 15 1000 Gal 0 ACID BREAKDOWN

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1989 EXPLORE ENERGY CORP. 37973.00 0.00 358
1990 EXPLORE ENERGY CORP. 34712.00 0.00 359
1991 EXPLORE ENERGY CORP. 39.00 0.00 360

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1989 EXPLORE ENERGY CORP. Brine 993 358
1990 EXPLORE ENERGY CORP. Brine 1245 359
1991 EXPLORE ENERGY CORP. Brine 140 360

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1398128507 2020-7-29 0:00: PW No Violations
-58577190 2017-11-8 0:00: PW No Violations
-940494114 2016-5-6 0:00:0 PW No Violations
-974114828 2017-5-10 0:00: PW No Violations
0000PL9006 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0058577190 2017-11-08 Production Wells No Violations Accompany Mr. Jeff Fry for safety to evaluate well for repair and plugging. Discussed well history, details and surrounding historical production, see his report for details.
0301966045 2017-11-08 Production Wells No Violations Accompany for safety Mr. Bill Mitton (Knox Energy) to evaluate gas leak at the well for repair. Discussed well information.
0787195001 2015-03-30 Production Wells Violations Noted Inspected the Beck #3 (#3825) as part of a standard domestic well status check accompanied by Jeff Fry. The well is equipped with a pump jack, rods and tubing. No identification is posted and noted H2S gas (6ppm) leaking from a corroded line fitting 15 from the well at the lease road. The valve for the line was partially open at the wellhead. We were met at the location by the owners grandson (Mr. Justin Beck) and asked him to attempt to carefully close the valve after soaking it with penetrating oil also discussed plugging procedures. NOTE- this well was originally drilled to the Trempealeau, but is perforated in the Lockport and no plug back record is noted. Status: will continue-to-monitor.
0940494114 2016-05-06 Production Wells No Violations Received phone call from the owner Mr. Richard Beck regarding the compliance notice. Gave him the contact information of an operator to assist him in repairing the well leak. Status: will continue-to-monitor.
0974114828 2017-05-10 Production Wells No Violations Inspected the Beck #3 (#3825) as a standard compliance notice follow-up.. Status: no change-in-status from previous inspection. The well remains idle, unidentified and overgrown with brush and trees. Photo-documented.
140369829 2019-12-17 0:00 PW No Violations 0.40
1427822051 2015-03-30 Production Wells No Violations Location Information for the Beck #3 (#3825). WELL HEAD: Lat. 40.57864 Long. -82.68712 / CENTER-OF-STORAGE: none / ENTRANCE: Lat. 40.57952 Long. -82.68713.
1427987437 2015-03-31 Production Wells No Violations This inspection was conducted with DOGRM Inspector Eric Daugstrup. Well is leaking H2S gas. See Erics report for inspection details.
1461350184 2016-04-20 Production Wells No Violations Compliance notice follow-up for previous gas leak and no identification. Status: no change in status from previous inspection. The business (Becks Auto Wrecking) has gone out-of-business since previous inspection. Well is leaking gas (with H2S) at the well head >12 ppm LEL caused PPE detector to go off. Owners phone number on record is disconnected. Neighbor stated owner has moved to Florida, left copy of compliance notice in mailbox of the address on record.
1461867970 2016-04-26 Production Wells No Violations Performed courthouse research on Beck #3 (#3825) domestic well. Auditor verbally confirmed that the property is in foreclosure and their address of record is the same as the one on file with the Division. Sent original compliance notice to address of record by certified mail. Status: will continue to monitor.
1509561458 2017-11-01 Production Wells Violations Noted Inspected the Beck #3 (#3825) as an odor complaint from a nearby resident. Strong hydrogen sulfide odor noted on township road #91. Previous inspections and violation written 3/30/2015 documented the well H2S leak and no repair has been made by the owner of record, the well leak needs repaired as soon as possible. The well is not being utilized domestically and shall be plugged. Mr. Richard Beck shall submit a written plugging schedule to Eric Daugstrup at Division of Oil & Gas Resource Management 116 E. High St., Mt. Vernon OH 43050-3402 within 30 days, per OAC 1501:9-11--operation in this matter.
1510586551 2017-11-08 Production Wells No Violations RBDMS list this well as DM or Domestic Well. This well has a pump jack with an electric motor and a horizontal separator. There are no storage tanks. This well has not been pumped since, 1-inch diameter trees and brush have grown in and around the pumpjack. This well was permitted and drilled with a cable tool rig to the Trempealeau Formation. The well was perforated in the Lockport and no plug back records are available. The well survey card shows 114 feet of 10-inch, 350 feet of 8-inch, and 2100 feet of 7-inch diameter casing(s). The well completion report confirms the same depths. The Division has a Surface Casing report and cement job witnessed by Division Inspector Sam Faust showing 518 feet of 8.625-inch diameter surface casing. There are two 2-inch annular valves coming from the outside of the 7-inch diameter casing that are in the open position. From one valve there is a regulator and a 1-inch plastic line that loops around and crosses through a 2-inch diameter metal tubing under the lease road. The well is audibly and physically leaking H2S Gas from a splice in the 1-inch plastic line approximately 15 feet south east of the well head. This leak is approximately 1 foot from where the 1-inch line enters the 2-inch diameter tubing. I obtained a H2S reading of > 266 ppm with my tango gas meter ( at the leak).The wind speed was approximately 8 miles per hour and blowing north to south. The nearest inhabited residence is 270 feet to the north east of the well belonging to Joshua Beck. With a normal wind flow from the south west H2S odors would go in the direction of the Joshua Beck Residence. The 1-inch and 2-inch diameter line enters below ground on the east side of the lease road and is unknown where it goes. The valves , fittings and tubing on the well head are corroded badly and there is concerns of safety that they may fail completely releasing uncontrolled volumes of H2S gas. This well is in the division Complaint data base number 5734. Contractor Bill Mi
1528918275 2018-06-15 Production Wells No Violations Inspected the Beck #3 (#3825) as part of a standard compliance notice follow-up. Status: the previous repairs on the well head are holding-no odors noted. The well remains idle and no plug permit has been received from the owner. Non-compliant.
1549041962 2019-02-01 Production Wells No Violations Inspected the Beck #3 (#3825) as part of a standard compliance notice follow-up. Status: the previous repairs on the well head are holding-no odors noted. The well remains idle and no plug permit has been received from the owner. The site was snow covered at the time of inspection.
1643575851 2017-11-28 Production Wells Violations Noted On-site as a request during emergency repair. Berry well service personnel repaired the gas leak and loaded the 7 casing with a brine/H2S scavenger and shut the well in. This clears the previous violation #787195001.
301966045 2017-11-8 0:00: PW No Violations
787195001 2015-3-30 0:00: PW No Violations
PL9006 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0787195001 US-OH-128940 2018-02-27 9-9-02 General Safety
0787195001 US-OH-128941 2018-02-27 9-9-05(A)1 Well insufficiently equipped to prevent escape of oil and gas
0787195001 US-OH-128942 2018-02-27 9-9-05(A)10 Failure to legibly identify well
1509561458 US-OH-114276 2018-03-08 NONE Well shall be plugged
1643575851 US-OH-116188 2018-03-09 9-9-02 General Safety
1643575851 US-OH-116189 2018-03-09 9-9-05(A)1 Well insufficiently equipped to prevent escape of oil and gas

For data sources see[9]