34-119-22078

Well Details

Well ID: 34-119-22078
Loading map...
Country: United States
State: Ohio
County: Muskingum
Municipality: Union Township
Operator Name: VORTEX ENERGY LLC
Well Pad ID:
Farm/Lease Name: BLACKWOOD ROY & LANA
License Status: Producing
License Date: 1969-05-29
Spud Date: 1969-05-28
Spud Drilling Contractor:
Final Drill Date: 1969-06-13
Well Total Depth: 4462.00 ft
Configuration: Vertical
Latitude: 39.980000
Longitude: -81.800000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1969-05-28
Completed 1969-06-13
Reached Total Depth 1969-06-13
Change of Owner 1998-03-13 Operator changed from 9999, NO OWNER to 4431, VALLEY ENTERPRISES
Change of Owner 2007-12-13 Operator changed from 4431, VALLEY ENTERPRISES to 1333, BIG SKY ENERGY INC
Change of Owner 2017-06-22 Operator changed from 1333, BIG SKY ENERGY INC to 9841, VORTEX ENERGY LLC
Record Last Modified 2017-06-22

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 4341 4344 6
2006-09-11 4327 4335 16
4327 4335 16
4327 4335 16
2006-09-11 4362 4369 12
2006-09-11 4347 4353 7

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 2000 Bbl 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1991 VALLEY ENTERPRISES 0.00 160.00 180
1992 VALLEY ENTERPRISES 0.00 175.00 250
1993 VALLEY ENTERPRISES 0.00 84.00 120
1994 VALLEY ENTERPRISES 0.00 0.00 0
1995 VALLEY ENTERPRISES 0.00 0.00 0
1996 BARR ROBERT V 0.00 0.00 0
2001 VALLEY ENTERPRISES 0.00 65.00 250
2008 BIG SKY ENERGY INC 457.00 0.00 365
2009 BIG SKY ENERGY INC 1323.00 157.00 365
2011 BIG SKY ENERGY INC 856.00 60.00 365
2012 BIG SKY ENERGY INC 679.00 74.00 366
2013 BIG SKY ENERGY INC 953.00 57.00 365
2014 BIG SKY ENERGY INC 0.00 0.00 365
2016 BIG SKY ENERGY INC 23.00 11.00 98
2017 BIG SKY ENERGY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1991 VALLEY ENTERPRISES Brine 0 180
1992 VALLEY ENTERPRISES Brine 0 250
1993 VALLEY ENTERPRISES Brine 5 120
1994 VALLEY ENTERPRISES Brine 0 0
1995 VALLEY ENTERPRISES Brine 0 0
1996 BARR ROBERT V Brine 0 0
2001 VALLEY ENTERPRISES Brine 0 250
2008 BIG SKY ENERGY INC Brine 0 365
2009 BIG SKY ENERGY INC Brine 0 365
2011 BIG SKY ENERGY INC Brine 0 365
2012 BIG SKY ENERGY INC Brine 0 366
2013 BIG SKY ENERGY INC Brine 0 365
2014 BIG SKY ENERGY INC Brine 0 365
2016 BIG SKY ENERGY INC Brine 0 98
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-951083711 2016-5-5 0:00:0 PW No Violations 0.50
0884579938 2016-05-17 Production Wells No Violations The follow-up inspection is due to a Temporary Restraining Order issued in the Trumbull County Court of Common Pleas and the Chiefs Order #2015-535, Chiefs Order #2016-105. This inspection is to verify that all domestic gas has been shut in. The well has been shut in by Big Sky Energy and verified by Patrick Shreve on day of 5-17-16.
0951083711 2016-05-05 Production Wells No Violations The follow-up inspection is due to a Temporary Restraining Order issued in the Trumble County Court of Common Pleas and the Chiefs Order #2015-535, Chiefs Order #2016-105.

The well is equipped with a pumping unit and the tubing and rod annulus are open. The valves are closed at the compressor and the main meter run.

1197498743 2007-12-12 Production Wells No Violations one tank and pumping unit. Not producing.
1557113043 2016-04-15 Production Wells No Violations The purpose of my inspection today is a Civil Action Follow-up. During the time of my inspection the production equipment includes two 100 bbl. tanks and one vertical separator. The well is equipped with 8.625 inch surface casing, 4.5 inch production casing, 1.5 inch tubing and rods. A pump jack powered by an electric motor is attached to the well head. The pump jack is not running at this time. The valves on the well head are in the opened position indicating that the well is in production. I spoke with the land owner and he stated that he is getting house gas from this well. Identification is present on the electric panel located beside the pump jack.
884579938 2016-5-17 0:00: PW No Violations 0.50

For data sources see[9]

References