34-133-24331

Well Details

Well ID: 34-133-24331
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: EVERFLOW EASTERN PARTNERS LP
Well Pad ID:
Farm/Lease Name: NORTON BROTHERS
License Status: Producing
License Date: 2007-08-21
Spud Date: 2007-09-19
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2007-09-24
Well Total Depth: 3915.00 ft
Configuration: Vertical
Latitude: 41.340000
Longitude: -81.370000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-12-08 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:12/8/2006, Expired Date:12/8/2007 6:00:00 AM, Drilling unit acres:45.16, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2007-03-29 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:3/29/2007, Expired Date:3/28/2008 6:00:00 AM, Drilling unit acres:45.16, Proposed Well Type:OG, Proposed Well Class:POOL
Correction to Well 2007-07-20 BASS ENERGY'S PERMIT HAS BEEN CANCELLED PER OPERATOR'S INSTRUCTIONS.
Change of Owner 2007-07-30 Operator changed from 1639, BASS ENERGY CO INC to 84, EVERFLOW EASTERN PTNS L P
APP 2007-08-21 Proposed Formations:CLINTON, Issued Date:8/21/2007, Expired Date:8/20/2008 6:00:00 AM, Drilling unit acres:45.16, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2007-09-24
Reached Total Depth 2007-09-24
Completion Report Received 2007-10-17
Construction Permit Expires 2008-08-20
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-01-25 3738 3810 50
3738 3810 50
3738 3810 50

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 8 2452 Bbl 80000 1000GALLONS HCL ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 EVERFLOW EASTERN PARTNERS LP 15476.00 801.00 365
2009 EVERFLOW EASTERN PARTNERS LP 12332.00 465.00 365
2010 EVERFLOW EASTERN PARTNERS LP 16530.00 656.00 365
2011 EVERFLOW EASTERN PARTNERS LP 16145.00 568.00 365
2012 EVERFLOW EASTERN PARTNERS LP 4392.00 166.00 366
2013 EVERFLOW EASTERN PARTNERS LP 4189.00 169.00 365
2014 EVERFLOW EASTERN PARTNERS LP 3947.00 174.00 365
2015 EVERFLOW EASTERN PARTNERS LP 3282.00 153.00 365
2016 EVERFLOW EASTERN PARTNERS LP 2431.00 93.00 365
2017 EVERFLOW EASTERN PARTNERS LP 1656.00 46.00 365
2018 EVERFLOW EASTERN PARTNERS LP 1776.00 95.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 EVERFLOW EASTERN PARTNERS LP Brine 1021 365
2009 EVERFLOW EASTERN PARTNERS LP Brine 542 365
2010 EVERFLOW EASTERN PARTNERS LP Brine 934 365
2011 EVERFLOW EASTERN PARTNERS LP Brine 546 365
2012 EVERFLOW EASTERN PARTNERS LP Brine 268 366
2013 EVERFLOW EASTERN PARTNERS LP Brine 260 365
2014 EVERFLOW EASTERN PARTNERS LP Brine 244 365
2015 EVERFLOW EASTERN PARTNERS LP Brine 172 365
2016 EVERFLOW EASTERN PARTNERS LP Brine 104 365
2017 EVERFLOW EASTERN PARTNERS LP Brine 84 365
2018 EVERFLOW EASTERN PARTNERS LP Brine 66 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0597839241 2015-05-05 UrbanProduction Wells No Violations I inspected this well and tank battery at the request of Chris Lachman (CSL Consulting) for safety compliance of the above ground storage tanks as part of the HUD review process in expansion of the Anna Maria Nursing Facility. The wellhead is secured by chain link fencing topped with three strands of barbed wire and the man door is locked. The well is operating with the aid of a plunger lift system and is equipped with a Kimray motor valve and BT-2000 logic controls. The valve on the annulus between the 8.625 surface casing and 4.5 production casing is open. The proper identification is posted on the fence. The tank battery contains two (2) 140 barrel tanks, a 50 barrel poly tank, and a horizontal separator. The tank battery is fenced and screened on the north and east sides with board on board fencing and both man doors are locked. The dike surrounding the tank battery measures 51(L) x 21(W) x 3(H) and exceeds SPCC requirements. The valves on the tanks are locked, the tank hatch lids are closed, and the vent stacks are plumbed to a 42 gallon charcoal filter equipped with a low-pressure relief valve. Both tanks are equipped with lightning arrestors and the equipment is properly spaced. The proper ID is posted on the fencing and well #24352 also produces to this tank battery. This facility meets the safety requirements outlined in Chapter 1509.021 and 1509.23 of the Ohio Revised Code and Chapter 1501:9-9-05 of the Ohio Administrative Code.
1191202007 2007-09-18 Drill / Deepen / Reopen No Violations Poulson Drilling is moving on site and will spud the well tomorrow. Pits are being dug in a sand and gravel.
1309456932 2007-09-24 Drill / Deepen / Reopen No Violations Poulson should TD the well within 24 hours. The drilling pits are lined and in good condition.
1310033807 2008-08-26 Preliminary Restoration No Violations Preliminary restoration is approved.
1595116735 2007-09-26 Drill / Deepen / Reopen No Violations Daileys Excavating and Chemtech were on site to solidify the drilling pits. There are no violations at this time.
597839241 2015-5-5 0:00:0 UP No Violations 1.00

For data sources see[9]

References