34-133-24401

Well Details

Well ID: 34-133-24401
Loading map...
Country: United States
State: Ohio
County: Portage
Municipality: Rootstown Township
Operator Name: C & T ENERGY OF EAST CANTON IN
Well Pad ID:
Farm/Lease Name: BREWSTER
License Status: Plugged and Abandoned
License Date: 2014-06-19
Spud Date: 2010-11-01
Spud Drilling Contractor: ADVENT DRLG
Final Drill Date: 2010-11-08
Well Total Depth: 4458.00 ft
Configuration: Vertical
Latitude: 41.130000
Longitude: -81.210000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2010-10-25 Proposed Formations:CLINTON, Issued Date:10/25/2010, Expired Date:10/24/2012 12:00:00 PM, Drilling unit acres:49.17, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2010-11-08
Completion Report Received 2010-12-20
APP 2014-06-19 Proposed Formations:CLINTON, Issued Date:6/19/2014, Expired Date:6/18/2016 12:00:00 PM, Drilling unit acres:49.17, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2014-11-26
Construction Permit Expires 2015-06-19
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2011-03-29 4270 4341 62
4270 4341 62
4270 4341 62

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2010-11-16 H2O 15 175486 Gal 100000 Superior Well Services

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2010 C & T ENERGY OF EAST CANTON IN 0.00 0.00 365
2011 C & T ENERGY OF EAST CANTON IN 8107.00 1354.00 0
2012 C & T ENERGY OF EAST CANTON IN 3948.00 840.00 366
2013 C & T ENERGY OF EAST CANTON IN 2363.00 573.00 365
2014 C & T ENERGY OF EAST CANTON IN 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2010 C & T ENERGY OF EAST CANTON IN Brine 5105 365
2011 C & T ENERGY OF EAST CANTON IN Brine 13642
2012 C & T ENERGY OF EAST CANTON IN Brine 12164 366
2013 C & T ENERGY OF EAST CANTON IN Brine 8210 365
2014 C & T ENERGY OF EAST CANTON IN Brine 70 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1368783849 2011-9-27 0:00: PL No Violations
-1470741240 2015-8-17 0:00: FR No Violations 0.50
-1680701980 2011-2-15 0:00: UP No Violations
-1867575113 2014-11-26 0:00 PB No Violations 8.00
-350575927 2011-6-14 0:00: PW No Violations
-946936584 2014-12-1 0:00: PB No Violations 1.00
0350575927 2011-06-14 Production Wells No Violations Preliminary restoration is due. The affected area needs graded, seeded and mulched. The tank battery and wellhead need locks on the gates and identification posted. These comments were relayed to Greg New who will address them as soon as possible.
0884803242 2011-02-03 UrbanProduction Wells No Violations The well has been turned on but the fence and the permanent ID have not been placed at the wellhead or the tank battery. I called Greg New and told him that the well cannot be turned on until the required fencing is installed. He said that the fence will be completed within a week.
0946936584 2014-12-01 Plug / Plug Back No Violations I was on location to check the status of this recently plugged and abandoned well. The circulating pit has been closed and the 8.625 surface casing has been cut off below grade and buried. The tank battery was removed prior to plugging operations. The risers from the flow and sales lines will need to be cut and capped below grade. Rob Frock (C&T Energy) said he will reclaim the site in the spring when the weather allows. No violations.
1171226933 2010-11-05 Urban Drill / Deepen / Reopen No Violations Advent is drilling ahead on fluid as required by permit. The pits are fenced, lined and in good condition.
1288734461 2010-11-01 Urban Drill / Deepen / Reopen No Violations Advent Drilling moved on location today and will spud the well later this evening. The drilling pits were being dug during this inspection. This is an urban location. No violations at this time.
1368783849 2011-09-27 Preliminary Restoration No Violations Preliminary restoration is approved.
1416855875 2014-11-24 Plug / Plug Back No Violations I received a call from Rob Frock (C&T) that they were moving in today to pull rods and tubing in preparation for plugging operations. I inspected the location today and the service rig had pulled the rods and were rigging up to pull the tubing. No violations.
1416943301 2014-11-25 Plug / Plug Back No Violations I was on location at 7:50am to witness plugging operations for this Clinton well. Phils Well Service, Petroset Cementing, Appalachian Well Surveys, and DP Operating were on location to conduct operations. Rob Frock (C&T Energy) got the equipment spotted at 9:30am and Petroset rigged up to the 4.5 casing. They then mixed and pumped 7.3 barrels (30 sacks) of cement slurry with 40lbs of cottonseed hulls and bullheaded the slurry to the bottom of the hole with 64 barrels of water. The hulls plugged off the perforations at 600psi and they sat on the plug for thirty minutes. The valve on the truck was opened and there was no flow-back to the tanks. Petroset racked out and Phils attempted to pull stretch on the casing (25,000-30,000lbs) and the derrick began to bow backwards and appeared to crack. Everyone evacuated the immediate area in case the derrick would fall over. Operations were shut down and will likely resume when they can get another service rig to location. No violations.
1418846592 2010-11-17 Urban Drill / Deepen / Reopen No Violations The well was fraced earlier today. Work will continue on building the tank battery and site reclamation. No violations at this time.
1470741240 2015-08-17 Final Restoration No Violations I was on location to check the final restoration status of this well site after it was plugged and abandoned on 11/26/2014. Final restoration was due at the end of February 2015. My inspection today found that all surface production equipment has been removed. The location is roughly graded and has been logged with stumps and brush around the location. I found several pumping rods in the vicinity of the former wellhead that need to be removed. I will talk to C & T Energy about removing the rods and advising them that a landowner waiver (Form 5) will be required to leave the flow/sales lines buried and the access road in place prior to approving final restoration.
1680701980 2011-02-15 UrbanProduction Wells No Violations The well has been turned on but the required fencing has not been installed. I called Greg New and told him to shut the well down until the fence is installed. He agreed to the shut down and will contact is fence contractor regarding how soon the job would be completed.
1867575113 2014-11-26 Plug / Plug Back No Violations I was on location to witness final plugging operations of this Clinton Sandstone well. Phils Well Service brought in their pole rig to finish the job. Appalachian Well Surveys shot the 4.5, 10.5lb/ft. casing off at a depth of 3029 and Petroset spotted cement plugs across the top of the Big Lime, at the bottom of the 8.625 surface casing, and from 200 below the top of the surface casing to surface. Good circulation was established prior to spotting the plugs. See plugging report for more details on this job. No violations.
2117916861 2010-12-15 Urban Drill / Deepen / Reopen No Violations The well has been fraced and the tank battery has been set. The required security fencing around the well and the tank battery still needs to be installed before the well can be turned on.
884803242 2011-2-3 0:00:0 UP No Violations

For data sources see[9]