If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-105-22461 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.16,"lon":-81.84,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Meigs | |
Municipality: Olive Township | |
Operator Name: MOUNTAINEER STATE OPERATIONS L | |
Well Pad ID: | |
Farm/Lease Name: CRAFT CL & ROBERT | |
License Status: Active Injection | |
License Date: 1985-07-19 | |
Spud Date: 1982-06-12 | |
Spud Drilling Contractor: CO TOOLS | |
Final Drill Date: 1983-06-15 | |
Well Total Depth: 1960.00 ft | |
Configuration: Vertical | |
Latitude: 39.160000 | |
Longitude: -81.840000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1982-06-04 | 248 SMITH CARL E PETROL INC GeoDate 6/4/82 |
Oil and Gas | 1982-06-04 | Issued Date 6/4/82 Expired Date 12/1/82 Acres 0036320 Tool Type RTAF Proposed Formation BEREA Proposed Depth 01960 Proposed Drill Depth 01960 |
Original Spud | 1982-06-12 | PERMIT EXPIRED |
Completed | 1983-06-15 | PERMIT EXPIRED |
Reached Total Depth | 1983-06-15 | PERMIT EXPIRED |
Completion Report Received | 1983-11-17 | PERMIT EXPIRED |
CO | 1985-07-19 | 248 SMITH CARL E PETROL INC GeoDate 7/19/85 |
Conversion to Injector | 1985-07-19 | |
Salt Water Injection Well | 1985-07-19 | Issued Date 7/19/85 Expired Date 7/19/86 Acres 0036320 Tool Type RTAF Proposed Formation BIG INJUN Proposed Depth 00000 Proposed Drill Depth 00000 |
Storage Well | 1985-07-19 | Issued Date 7/19/85 Expired Date 7/19/86 Acres 0036320 Tool Type RTAF Proposed Formation BIG INJUN Proposed Depth 00000 Proposed Drill Depth 00000 |
First Injection | 1986-01-28 | PERMIT EXPIRED |
Construction Permit Expires | 1986-07-19 | PERMIT EXPIRED |
Annulus Pressure Monitoring Approved | 1989-03-22 | PERMIT EXPIRED |
Last Compliance Report | 2013-08-12 | PERMIT EXPIRED |
Change of Owner | 2019-03-12 | Operator changed from 248, CARL E SMITH PETROLEUM INC to 8473, MOUNTAINEER STATE OPERATIONS LLC |
Record Last Modified | 2019-03-12 | PERMIT EXPIRED |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2000-05-02 | 1395 | 1425 | 0 |
2000-05-02 | 1845 | 1853 | 16 |
1845 | 1853 | 16 | |
1395 | 1425 | 0 | |
1395 | 1425 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
0 | 0 | 0 | ||||
FOAM | 0 | 250 Gal | 30000 | FRAC;645BBL H2O,30M# SD |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | CARL E SMITH PETROLEUM INC | 490.00 | 0.00 | 0 |
1985 | CARL E SMITH PETROLEUM INC | 365.00 | 0.00 | 0 |
2009 | CARL E SMITH PETROLEUM INC | 0.00 | 0.00 | 0 |
2010 | CARL E SMITH PETROLEUM INC | 0.00 | 0.00 | 0 |
2011 | CARL E SMITH PETROLEUM INC | 0.00 | 0.00 | 0 |
2012 | CARL E SMITH PETROLEUM INC | 9.00 | 0.00 | 366 |
2013 | CARL E SMITH PETROLEUM INC | 0.00 | 0.00 | 365 |
2014 | CARL E SMITH PETROLEUM INC | 0.00 | 0.00 | 365 |
2015 | CARL E SMITH PETROLEUM INC | 0.00 | 0.00 | 365 |
2016 | CARL E SMITH PETROLEUM INC | 0.00 | 0.00 | 365 |
2017 | CARL E SMITH PETROLEUM INC | 0.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | CARL E SMITH PETROLEUM INC | Brine | 0 | 0 |
1985 | CARL E SMITH PETROLEUM INC | Brine | 0 | 0 |
2009 | CARL E SMITH PETROLEUM INC | Brine | 0 | 0 |
2010 | CARL E SMITH PETROLEUM INC | Brine | 5880 | 0 |
2011 | CARL E SMITH PETROLEUM INC | Brine | 0 | 0 |
2012 | CARL E SMITH PETROLEUM INC | Brine | 5628 | 366 |
2013 | CARL E SMITH PETROLEUM INC | Brine | 1320 | 365 |
2014 | CARL E SMITH PETROLEUM INC | Brine | 1380 | 365 |
2015 | CARL E SMITH PETROLEUM INC | Brine | 380 | 365 |
2016 | CARL E SMITH PETROLEUM INC | Brine | 0 | 365 |
2017 | CARL E SMITH PETROLEUM INC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1018170063 | 2005-7-28 0:00: | SW | No Violations | |
-1037924716 | 2017-4-11 0:00: | SW | No Violations | 2.50 |
-1067600848 | 2018-5-9 0:00:0 | SW | No Violations | 1.00 |
-1116407205 | 2012-10-10 0:00 | SW | No Violations | 3.00 |
-1141630130 | 2018-9-14 0:00: | SW | No Violations | 1.40 |
-1175157537 | 2012-7-23 0:00: | SW | No Violations | |
-1222998948 | 2014-8-19 0:00: | SW | No Violations | 1.50 |
-1297660666 | 2013-9-26 0:00: | SW | No Violations | 0.70 |
-1301105884 | 2018-8-31 0:00: | SW | No Violations | 2.70 |
-1329598600 | 2013-5-6 0:00:0 | SW | No Violations | |
-1330358226 | 2016-10-24 0:00 | SW | No Violations | 1.00 |
-1360584588 | 2019-11-4 0:00: | SW | No Violations | 3.60 |
-1374084100 | 2012-2-17 0:00: | PW | No Violations | 1.00 |
-1381618046 | 2014-6-18 0:00: | SW | No Violations | 2.50 |
-1412153767 | 2012-12-11 0:00 | SW | No Violations | 1.50 |
-1418072846 | 2016-5-25 0:00: | SW | No Violations | 1.50 |
-1507873521 | 2003-12-4 0:00: | SW | No Violations | |
-1545213138 | 2015-3-12 0:00: | SW | No Violations | 0.70 |
-1638893080 | 2011-3-30 0:00: | SW | No Violations | |
-1640676888 | 2019-8-19 0:00: | SW | No Violations | 1.10 |
-1643148761 | 2004-8-17 0:00: | SW | No Violations | |
-1649729114 | 2015-9-29 0:00: | SW | No Violations | 0.40 |
-1655422871 | 2010-12-16 0:00 | SW | No Violations | |
-1662974527 | 2018-9-18 0:00: | SW | No Violations | 0.50 |
-1690649312 | 2005-10-20 0:00 | SW | No Violations | |
-1700705447 | 2010-6-21 0:00: | SW | No Violations | 2.00 |
-1769705098 | 2009-3-11 0:00: | SW | No Violations | |
-1786436592 | 2012-7-23 0:00: | SW | No Violations | 0.30 |
-1797620057 | 2013-11-21 0:00 | SW | No Violations | 4.00 |
-193252665 | 2008-12-3 0:00: | SW | No Violations | |
-1942460667 | 2014-9-24 0:00: | SW | No Violations | 1.20 |
-2035767506 | 2009-11-6 0:00: | SW | No Violations | |
-2093005892 | 2019-3-12 0:00: | SC | No Violations | 2.50 |
-2128940937 | 2014-9-5 0:00:0 | SW | No Violations | 1.00 |
-2134957181 | 2019-1-24 0:00: | SW | No Violations | 3.20 |
-237514194 | 2011-12-13 0:00 | SW | No Violations | |
-292930104 | 2019-12-9 0:00: | SW | No Violations | 2.20 |
-359669366 | 2011-5-26 0:00: | SW | No Violations | 3.00 |
-363853365 | 2013-8-7 0:00:0 | SW | No Violations | 10.00 |
-449619932 | 2012-7-5 0:00:0 | PL | No Violations | 0.80 |
-48034223 | 2007-2-21 0:00: | SW | No Violations | |
-687807558 | 2019-2-11 0:00: | SW | No Violations | |
-747978198 | 2004-2-5 0:00:0 | SW | No Violations | |
-782250667 | 2018-2-16 0:00: | SW | No Violations | |
-802416146 | 2003-8-21 0:00: | SW | No Violations | |
-871236474 | 2012-3-2 0:00:0 | SW | No Violations | 1.30 |
-916899097 | 2002-2-20 0:00: | SW | No Violations | |
-953659101 | 2005-1-12 0:00: | SW | No Violations | |
-955938628 | 2014-2-25 0:00: | SW | No Violations | 0.70 |
-996915144 | 2012-2-14 0:00: | SW | No Violations | |
000PL11123 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0020041082 | 2007-07-17 | Salt Water Injection Well | No Violations | No violations were found at the time of inspection. |
0048034223 | 2007-02-21 | Salt Water Injection Well | No Violations | All conditions were acceptable. |
0076793142 | 2011-12-15 | Salt Water Injection Well | No Violations | Accompanied J. Scott on SWIW inspection. Dike has roughly 6 inches of water in bottom of it. No other violations. Well on vacuum. |
0120696642 | 2015-04-29 | Salt Water Injection Well | No Violations | Follow up to 527703964. A Mechanical Integrity Test was performed. The annulus was filled with fresh water the day before. 410 psi was placed on the annulus and only 2 psi was lost during the 15 minute test. |
0193252665 | 2008-12-03 | Salt Water Injection Well | No Violations | No violations were found. |
0194209111 | 2008-06-10 | Salt Water Injection Well | No Violations | No violations were found at the time of inspection. |
0237514194 | 2011-12-13 | Salt Water Injection Well | No Violations | Accompanied by Josh Garland MRI. No violations observed during inspection. |
0240283625 | 2017-07-31 | Salt Water Injection Well | No Violations | UIC quarterly inspection. The annulus pressure was 62 PSI, the injection tubing was on vacuum. Legible identification was posted. |
0294491020 | 2017-02-23 | Salt Water Injection Well | No Violations | Inspected the containment dikes, tanks, injection line, injection pressure, and annulus pressure. Identification is posted. 4 small holes were observed in the containment dike liner with the 3 horizontal tanks. The holes in the liner appear to be made by an animal clawing out of the dike. The holes were marked with orange tape. John Kent was called and notified of the holes in the liner. |
0359669366 | 2011-05-26 | Salt Water Injection Well | No Violations | Accompanied J. Scott on complaint of brine dumping. Roughly 10 pine trees had been killed/stressed by the spill. Owner states it was accidental. |
0363853365 | 2013-08-07 | Salt Water Injection Well | No Violations | Installed new Halliburton R-4 packer with used 2 3/8 10 round tubing. Circulated 40 barrels fresh water through tubing prior to setting packer. (last 20 barrels fresh water had 2 gallons inhibitor ) Set packer at 1305.40 feet. Pulled 13,000 lbs tension. Tested the annulus at 415 psi for 15 minutes. At 5 minutes 415 psi. at 15 minutes 408 psi. Test passed. |
0399321842 | 2006-08-16 | Salt Water Injection Well | No Violations | No violations were found. |
0427392225 | 2003-03-05 | Salt Water Injection Well | Violations Noted | FOLLOW UP TO NOV # 737973241 An inspection of the well revealed there is no fittings on the Injection side or the Annulus side of well to check pressures. NEED 1/4 FIITINGS ON WELL, UNABLE TO CHECK PRESSURES ON WELL. |
0449619932 | 2012-07-05 | Preliminary Restoration | No Violations | Water still in dike. A hose was noticed running over the edge of the dike into the wood line. There is no pump means to gravity feed water out of the dike using the hose. And there does not appear to be any affected vegetation outside the dike where the hose terminates. |
0506861824 | 2009-11-05 | Surface Facility Construction | No Violations | Reconstruction of dike. Dike measures 21 by 46 by 2. Submitted dike plan to Tom Tomastik for approval. |
0514524137 | 2013-01-24 | Salt Water Injection Well | No Violations | Dikes are free of water. Some work has been done to the fence near the well and the identification is on the ground. Inspected the injection tubing pressure and the annulus pressure. |
0527703964 | 2015-04-28 | Salt Water Injection Well | Violations Noted | The injection tubing and the annulus were both on a slight vacuum. A pressure test shall be performed in order to demonstrate mechanical integrity. |
0635380578 | 2019-04-22 | Salt Water Injection Well | No Violations | Inspected the unloading pad, containment dikes, tanks, injection line, injection pressure and annulus pressure. Identification is posted. The containment dikes are free of fluids. |
0656929786 | 2009-06-09 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
0667869530 | 2011-08-24 | Salt Water Injection Well | No Violations | Water in dikes. Called Tom Stone, he said that he will take care of the water. |
0687807558 | 2019-02-11 | Salt Water Injection Well | Violations Noted | The Division has not received the 2nd, 3rd, & 4th quarter brine disposal fees for 2018. Please forward disposal fees and sheets to the Division by 3/12/2019. |
0704144641 | 2009-11-06 | Surface Facility Construction | No Violations | Reconstruction of dike and liner. Install 30 mil liner in dike with 3-6000 gallon tanks. 6 of sand was placed below the liner and 6 of sand was placed on top of the liner. |
0724406249 | 2005-05-10 | Salt Water Injection Well | No Violations | There were no violations. However, additional tanks on site appear to have an inadequate dike capacity. |
0736867213 | 2016-01-06 | Salt Water Injection Well | No Violations | No noted violations. Facility does not appear to have been used lately according to log book. |
0737973241 | 2003-03-05 | Salt Water Injection Well | Violations Noted | An inspection of the well revealed there is no fittings on the Injection side or the Annulus side of well to check pressures. NEED 1/4 FIITINGS ON WELL, UNABLE TO CHECK PRESSURES ON WELL. |
0739669403 | 2011-09-27 | Salt Water Injection Well | No Violations | Fresh water in dikes from recent rain event. |
0742004490 | 2009-11-24 | Salt Water Injection Well | No Violations | Three 6,000 gallon tanks are in the new dike and are connected to injection equipment. The second dike liner has not been patched. Damage appears to be from deer in the dike. |
0746814585 | 2008-03-10 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
0747978198 | 2004-02-05 | Salt Water Injection Well | No Violations | No violations at the time of inspection. |
0753515775 | 2018-09-11 | Salt Water Injection Well | No Violations | Compliance Notice # 1534352012 follow up inspection. Good vegetative growth on the remediation area. The containment dike is full of water with an oil sheen. I called Ron the well tender. Ron told me that they have Harmon Services brine truck scheduled to pump out the dikes. |
0778986041 | 2004-05-03 | Salt Water Injection Well | No Violations | Unable to access 1/4 inch female fitting on the tubing, because the plug started to round-off. |
0782250667 | 2018-02-16 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 1st, 2nd, 3rd, & 4th quarter of 2017 . Please submit the appropriate reports by March 17, 2018. Reports Received 5/2/2018 |
0802416146 | 2003-08-21 | Salt Water Injection Well | No Violations | No violations at the time of inspection. |
0861642675 | 2013-10-30 | Salt Water Injection Well | No Violations | Follow up to -1297660666. The injection tubing was equipped with a fitting to monitor mechanical integrity. |
0871236474 | 2012-03-02 | Salt Water Injection Well | No Violations | The pits are being emptied. |
0916899097 | 2002-02-20 | Salt Water Injection Well | No Violations | |
0953659101 | 2005-01-12 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
0955938628 | 2014-02-25 | Salt Water Injection Well | No Violations | No noted violations. |
0996915144 | 2012-02-14 | Salt Water Injection Well | Violations Noted | Dikes are full of water with an ice layer on top. I called John Kent and told him to remove the water from the dikes. He said that he will have someone do it no later than the 2-15-12. |
1000205479 | 2010-09-14 | Administrative Inspection | No Violations | Received call at 11:21 am from Tom Stone Re: Dike construction for two 100 bbl tanks. Tom told me that the dike dimensions are 42 by 28 by 4 with the tanks sitting on an mound of dirt in middle of dike. Liner will be over the mound of dirt. They will place sand under the liner and on top of liner. |
1007804655 | 2020-3-5 0:00:0 | SW | No Violations | |
1018170063 | 2005-07-28 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
1037924716 | 2017-04-11 | Salt Water Injection Well | No Violations | Inspected the containment dikes, tanks, unloading pad, injection line, injection pressure and annulus pressure. Identification is posted. The containment dikes had 3 inches of water in them. |
1042410009 | 2012-11-29 | Production Wells | No Violations | Follow up to inspection 1354126946. The contaminated soils have been removed. The remaining soil was field tested for pH and my test strips read between 6 and 7. |
1067600848 | 2018-05-09 | Salt Water Injection Well | No Violations | Inspected the unloading pad, containment dikes, tanks, injection line, injection pressure and annulus pressure. Identification is posted. |
1116407205 | 2012-10-10 | Salt Water Injection Well | No Violations | FOLLOW UP TO NOV # 1350659426 Injection tubing is full of fluid. Unloading pad drain has soil with vegetation growing out of the grate. Both dikes have water in them (6-12 inches). Brine hauling log on site shows only one small load hauled on 9-21-12 from tank compressor 1000 gallon tank. Load was put into # 2 tank. Called John Kent and we discussed the need to keep water out of the dikes. We also discussed the wells condition and the fact that they are not injecting water at this time. John told me that they are planning an acid treatment to help open up the formation. They are hauling their production water to Athens injection well. |
1124911254 | 2004-03-09 | Salt Water Injection Well | No Violations | No violations at the time of inspection. |
1128616425 | 2018-08-16 | Salt Water Injection Well | No Violations | Compliance Notice # 1534352012 follow up inspection. ODNR DOGRM ER Lane on location. Tested the scald area with conductivity meter and determined that the scald is from oil spray. Absorbent material has been spread on oil and brine in containment dike. Nothing has been applied to the scald areas outside of the containment dike. |
1138651007 | 2006-01-18 | Salt Water Injection Well | No Violations | No violations at this time. |
1141630130 | 2018-09-14 | Salt Water Injection Well | No Violations | Compliance Notice # 1534352012 follow up inspection. The containment dike has had 15 inches of fluid pumped out of it. There are still 6 inches of fluid with an oil sheen in the dike with the two 100 barrel tanks. The second dike with three horizontal tanks has 8 inches of fluid in it. There is good vegetative growth on the remediation areas outside of the dike. I called Ron the well tender and left a message about needing to have the containment dikes free of fluids. |
1153166584 | 2006-06-22 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
1165081060 | 2004-07-15 | Salt Water Injection Well | No Violations | No violations. |
1175157537 | 2012-07-23 | Salt Water Injection Well | No Violations | Zero pressure on injection tubing. Last recorded brine transport in log book dated 12-14-11. 1000 gallons from compressor yard. Last recorded company annulus test (monthly test) on 6-4-12. |
1184353497 | 2013-05-13 | Salt Water Injection Well | No Violations | Checked injection pressure and annulus pressure. Containment dikes have 4 of water in the low areas of the dike. (recent rain event) I called and talked to John Kent about the dike water and the need to extend the unloading pad so that their truck will fit on it. John told me that they are scheduling a service rig to pull and replace the tubing and packer. |
120696642 | 2015-4-29 0:00: | SW | No Violations | 1.30 |
1216370383 | 2013-08-06 | Salt Water Injection Well | No Violations | Francis Brothers service rig on well. Released packer and pulled packer and tubing out of the well. Shut in well head. All valves are closed. |
1222998948 | 2014-08-19 | Salt Water Injection Well | Violations Noted | Unable to test the annular space because the gauge was rounded off and I was unable to remove it. |
1251299827 | 2007-04-12 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
1252004373 | 2009-08-27 | Salt Water Injection Well | Violations Noted | Zero pressure on injection. 100psi on annulus. 3storage tanks 6000 gallons each are located in a dike. They appear to be for storage and possible filtering. The dike liner is torn and damaged in multiple areas. 2 100bbl tanks are also located on site in a different dike. This dike liner appears intact. I called Adam Schoppe and discussed the violations and he is going to arrange the necessary work in the field. I told Adam that the liner needs to be 30 mil with 4 sand under and 4washed gravel over the liner. I also mentioned that they need to check the dike capacity and make sure that it will hold the correct amount. |
1262709163 | 2009-10-13 | Administrative Inspection | No Violations | Received a call from Adam Schope (Mountaineer) Re: What is the minimum thickness for the liner. I told Adam a 30 mil liner needs to be installed. Adam will call me when they get ready to replace the liner. |
1271072997 | 2010-03-17 | Salt Water Injection Well | Violations Noted | Dike has water in dike with the three 6000 gallon tanks. The dike with the two 100 bbl tanks has some small holes in side of dike liner from deer walking over the dike. I have called Adam Schoppe and have given him an verbal NOV for the water in dike needing to be removed and that they need to repair or replace the 100 bbl dike liner. I called Adam on 3-18-10 at 10:24 am. Pictures were taken. Well has good id. Well is connected for disposal. |
1284500155 | 2010-09-10 | Administrative Inspection | No Violations | Received call from Tom Stone Re: Tanks will be delivered Monday. Plan to install pit liner on Tuesday 9-14-10. I reminded Tom and John Kent that the dike must be able to hold 110% of tank capacity. |
1296183907 | 2018-03-14 | Salt Water Injection Well | No Violations | My inspection revealed the salt water injection well had 0 psi on the tubing and 130 psi on the annulus. The dike was free of fluids. Legible identification was posted. |
1297660666 | 2013-09-26 | Salt Water Injection Well | Violations Noted | Unable to test injection pressure because the line had been disconnected. The tubing ended in a 2 ball valve, a 90 degree elbow, and a plug. The company has recently reset the packer and plans to perform an acid job by the end of the month. After the acid job the well shall be fitted with valve and connection in order to monitor mechanical integrity. |
1300926899 | 2014-05-20 | Salt Water Injection Well | No Violations | No noted violation. |
1301105884 | 2018-08-31 | Salt Water Injection Well | No Violations | Compliance Notice # 1534352012 follow up inspection. The containment dike with the two 100 barrel steel tanks has 12 inches of fluid in it. The affected areas outside of the containment dike has been remediated with seed and mulch applied. Good vegetative cover is starting to establish. |
1327924250 | 2018-11-05 | Salt Water Injection Well | No Violations | Inspected the containment dikes, tanks, unloading pad, injection pressure and annulus pressure. Identification is posted. The injection tubing master valve is closed. The injection line from the 100 barrel tank is closed. The containment dike has water in it from rain event. Ron the well tender was called about pumping out the containment dike water. |
1329598600 | 2013-05-06 | Salt Water Injection Well | No Violations | FOLLOW UP TO NOV # 1350659426. There was not a significant amount of water in the dike (raining at time of inspection), the drain on the offloading pad had been cleaned out and was functioning, the manifest at the well states the last time of drop off was 5/1/13 and the well was tested by the company. |
1330358226 | 2016-10-24 | Salt Water Injection Well | No Violations | Inspected the containment dikes, tanks, injection line, injection pressure, annulus pressure , and unloading pad. Identification is posted. |
1330871870 | 2008-09-10 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
1340632907 | 2012-06-25 | Salt Water Injection Well | No Violations | A small amount of water is in the lower side of the large dike. The 3/4 plug is rounded off and was difficult to remove. |
1341849755 | 2012-07-09 | Salt Water Injection Well | No Violations | Water still in dike. The valve on the annular space was replaced but was replaced with too large a fitting. I notified the company and will be back in a few days to check on the progress. |
1347600437 | 2013-10-25 | Salt Water Injection Well | No Violations | Follow up to -1297660666. The fitting on the injection tubing have not yet been installed to allow for mechanical integrity testing. |
1350659426 | 2012-10-10 | Salt Water Injection Well | Violations Noted | Injection tubing is full of fluid. Unloading pad drain has soil with vegetation growing out of the grate. Both dikes have water in them (6-12 inches). Brine hauling log on site shows only one small load hauled on 9-21-12 from tank compressor 1000 gallon tank. Load was put into # 2 tank. Called John Kent and we discussed the need to keep water out of the dikes. We also discussed the wells condition and the fact that they are not injecting water at this time. John told me that they are planning an acid treatment to help open up the formation. They are hauling their production water to Athens injection well. |
1354126946 | 2012-11-28 | Production Wells | Violations Noted | Witnessing an acid job. Three Barrels of a 28% Iron Acid -20M was mixed in the tubs with 6 Barrels of fresh water for the acid treatment. The diluted acid mixture was allow to sit in the mix tub too long and corroded through the welds on the tubs. The mixture then mixed with the limestone along the lease road creating a caustic foam that impacted the area. Roughly 480 square feet of limestone lined lease road was impacted under the truck and roughly 40 square feet of soil was impacted near the well head. The acid ran along a ditch roughly 45 feet before encountering a culvert. The acid does not appear to have traveled through the culvert. Contaminated soils and gravel shall be removed and disposed of properly. If a significant amount of impacted soil is removed topsoil shall be replaced to restore the surface to its original grade. Impacted are shall be seeded and mulched and steps shall be taken to encourage vegetative cover. |
1354287102 | 2012-11-30 | Production Wells | No Violations | Follow up to inspection 1354126946. The limestone gravel has been replaced. The contaminated soil has been replaced and fresh top soil has been laid down. The area has been seeded and mulched in order to encourage vegetative cover. Landscaping mesh has been laid down over the mulch to ensure the mulch remains on site. The culvert has been cleaned out. The soil in the lease road was field tested for acidity and it registered a pH of 7. Pictures of the reclamation taken. The UIC numbers and log of a Viking Well Services Brine truck on site were also verified. |
1354290366 | 2012-11-29 | Administrative Inspection | No Violations | I called and talked to John Kent Re: what is their plan for getting the well capable for injection. John told me that they are rescheduling the acid stimulation for the 1st week of December 2012. |
1355248202 | 2012-12-11 | Salt Water Injection Well | No Violations | Company attempted an acid treatment on well. Three Barrels of 28% Iron Acid were pumped into tubing but were never displaced into formation. Pressure was raised to 300 psi multiple times but the acid never left the tubing. The tubing will be swabbed clean and acid will be stored in a plastic tank for future use. The annular pressure was monitored during the treatment and there was no sign of communication. During the treatment the annular space had no pressure on it while the injection tubing had 300 psi. |
1359490911 | 2013-01-29 | Salt Water Injection Well | No Violations | There is still roughly 1-1.5 feet of water in the dike. The drain on the offloading pad is still plugged and full of water. |
1365788127 | 2013-04-12 | Salt Water Injection Well | No Violations | Inspected the containment dikes, tanks, unloading pad, injection pressure and annulus pressure. Identification at wellhead. |
1374084100 | 2012-02-17 | Production Wells | Violations Noted | Follow up to a verbal compliance notice originally issued 2/14/12 by Jon Scott for water in the dikes at the injection facility. Upon inspection there was roughly a foot of water in both of the containment dikes. Dikes shall be kept empty of all fluids. |
1377085894 | 2013-08-15 | Salt Water Injection Well | No Violations | Injection line is disconnected from the injection tubing. John Kent is scheduling an acid stimulation prior to placing well back into service. Both containment dikes have 5 of water in them from the last rain event. |
1381618046 | 2014-06-18 | Salt Water Injection Well | No Violations | Inspected the containment dikes, tanks, unloading pad, injection pressure and annulus pressure. Identification posted at well. Well is connected for injection. The containment dike with the two 100 barrel steel tanks has approximately 10 inches of water in it. I called John Kent and left a message about the water in the dike and that he needs to remove it and keep the dike free of fluids. |
1385559389 | 2013-11-22 | Administrative Inspection | No Violations | Talked to Tom Stone about the acid job on 11-15-13. Tom said that they spilled 1.5 gallons of acid and cleaned it up and applied lime to the site. I asked for a job report from the service company. Tom said that he will ask John Kent to send one to me. |
1398681394 | 2004-04-08 | Salt Water Injection Well | No Violations | No violations at the time of inspection. |
1403943332 | 2013-01-17 | Production Wells | No Violations | Follow up to inspection done 10/10/12. The drain under the off-loading pad was full of water and is incapable of functioning correctly. The lower dike contained 1-2 feet of water. The drain in the off-loading pad shall be repaired or replaced in order to allow the off-loading pad to drain fluids. The water shall be removed from the lower dike. |
1406885551 | 2010-09-27 | Salt Water Injection Well | No Violations | Replaced two 100 bbl steel tanks and rebuilt dike with new 30 mil liner. Tanks are plumbed and in operation. |
1410955294 | 2014-09-16 | Salt Water Injection Well | No Violations | Follow up to -1222998948. Still unable to test annulus. Called company to correct fittings. |
1412153767 | 2012-12-11 | Salt Water Injection Well | No Violations | Acid job. Josh Garland MRI 2 was on site. I stopped by to check on the progress. Unable to pump through tubing. Acid started to cause leaks on the pump truck. Operation was shut down. I discussed with Tom Stone the need to clean out the well prior to another acid job. |
1418072846 | 2016-05-25 | Salt Water Injection Well | No Violations | Inspected the containment dikes, tanks, unloading pad, injection line, injection pressure and annulus pressure. Identification posted. |
1445286044 | 2015-10-09 | Salt Water Injection Well | No Violations | No noted violations. |
1447936836 | 2015-11-18 | Salt Water Injection Well | No Violations | Inspected the containment dikes, tanks, injection line, injection pressure, annulus pressure and unloading pad. Discussed updates to the facility with the field crew from Mountaineer. The crew was pumping the water from the containment dikes into tanks. |
1469707431 | 2016-07-26 | Salt Water Injection Well | No Violations | Inspected the containment dikes, tanks, unload pad, injection line, injection pressure and annulus pressure. Identification posted. Containment dikes are free of fluids. |
1471281353 | 2006-04-04 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
1488488081 | 2017-02-28 | Salt Water Injection Well | No Violations | Our records indicate that the Division has not received the Salt Water Injection Well disposal fees for the 1st, 2nd, 3rd, & 4th quarters of 2016. Please submit the appropriate reports by March 14, 2017. Reports received 3/21/2017 |
1489085299 | 2017-03-07 | Surface Facility Construction | No Violations | Holes in the dike liner have been repaired. |
1489442712 | 2017-03-13 | Salt Water Injection Well | No Violations | Inspected the surface facility that consists of a plastic lined earthen containment dike with three 8,000 gallon steel tanks connected in a series, one 8,000 gallon tank was 2/3 full of fluid, the other two 8,000 gallon tanks are empty, A second plastic lined earthen containment dike with two 100 barrel steel tanks ( both 100 barrel tanks are empty), an unloading pad with a buried vault, Injection line (valve closed) with inline filter housing. The injection line is connected to the injection tubing. The injection pressure is zero. The injection tubing master valve is open. The annulus pressure is 20 psi. Both containment dikes have 3 inches of water in the deep ends of the dikes. Identification is posted at the well site. |
1507873521 | 2003-12-04 | Salt Water Injection Well | No Violations | No violations at the time of inspection. |
1534352012 | 2018-08-15 | Salt Water Injection Well | Violations Noted | Inspected the unloading pad, containment dikes, tanks, injection line, injection pressure and annulus pressure. Multiple scald areas were observed during the inspection. 1st. 15 feet West of the injection well 24 feet by 21 feet. 2nd 36 feet south oh the well 45 feet by 18 feet (area with distressed and dead vegetation.) 3rd. 6 feet east of the well 8 feet by 6 feet. There is 10 inches of oil and brine in the down slope section of the containment dike. The containment dike has two 100 barrel steel tanks. The two inch valve on the injection line is open. I called John Kent at 12:25 pm, and left a message with his receptionist about the release and the need to clean up the contamination. ODNR DOGRM duty officer was notified along with the ODNR DOGRM UIC supervisor. All contaminated material must be disposed of at an EPA approved landfill. The containment dike must be kept free of brine and oil. |
1537367583 | 2018-09-19 | Salt Water Injection Well | No Violations | Compliance Notice # 1534352012 follow up inspection. Both containment dikes are free of fluids. Good vegetative cover has been established on the remediated areas outside of the containment dike. The injection line and injection tubing master valves are closed. Checked injection tubing pressure and annulus pressure. Identification is posted. |
1537757963 | 2008-04-21 | Salt Water Injection Well | No Violations | There were no violations at the time. |
1545213138 | 2015-03-12 | Salt Water Injection Well | No Violations | No noted violations. |
1638893080 | 2011-03-30 | Salt Water Injection Well | No Violations | No violations at this time. |
1643148761 | 2004-08-17 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
1646434182 | 2013-07-10 | Salt Water Injection Well | No Violations | The vault in the unloading pad was functioning correctly. Tanks are being painted. The last load at the facility was delivered about 6 months ago according to the manifest at the well. |
1649729114 | 2015-09-29 | Salt Water Injection Well | No Violations | No noted violations. |
1655422871 | 2010-12-16 | Salt Water Injection Well | No Violations | Good identification. Dikes looked good. |
1662974527 | 2018-09-18 | Salt Water Injection Well | No Violations | compliance Notice # 1534352012 follow up inspection. There is 10 inches of fluid with an oil sheen in the 100 barrel tank dike. There is 10 inches of fluid in the horizontal tank dike. |
1667580863 | 2006-12-18 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
1690649312 | 2005-10-20 | Salt Water Injection Well | Violations Noted | FAILURE TO SUBMIT ANNUAL SALTWATER INJECTION WELL REPORTS FOR 2003 AND 2004 |
1700705447 | 2010-06-21 | Salt Water Injection Well | Violations Noted | Water in dike with 3- 6000 gal tanks. Needs pumped out. Leaking 100 bbl tank, also dike liner with 2- 100 bbl tanks has a cut and assorted small holes in the liner. I called and talked to Tom Stone about these issues and he told me that John Kent will be calling me to discuss the violations and to come up with a plan to correct the problems. 100 bbl tank needs to be replaced. New dike liner installed. |
1769705098 | 2009-03-11 | Salt Water Injection Well | No Violations | No violations were found. |
1777673751 | 2004-10-07 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
1783058637 | 2006-10-17 | Salt Water Injection Well | No Violations | There were no violations. Accompanied by Jon Scott. |
1783493449 | 2005-06-23 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
1786436592 | 2012-07-23 | Salt Water Injection Well | No Violations | The fittings have been changed to the appropriate size. There is still water in the dike. Jon Scott had taken the pressures earlier today, I did not check them. |
1795553448 | 2016-03-16 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on February 15th for 2015, despite a letter that was sent March 1, 2016 with a deadline of March 15, 2016 to submit the reports requested. REPORTS RECEIVED |
1797620057 | 2013-11-21 | Salt Water Injection Well | No Violations | Inspected the unloading pad, containment dikes, tanks, injection pressure and annulus pressure. Injection tubing has a valve that is closed. The injection tubing is not connected to injection line due to a well stimulation on 11-15-13. The landowner Mr. Craft told me that acid was spilled on the location during the well stimulation on 11-15-13. Lime powder was observed in multiple locations. Mr. Craft told me that most of the acid went into the dike and was removed with a vacuum truck. I called John Kent and asked about the release. John said that he did not know about it and would ask the field staff about the details. I requested to know the quantity and type of acid that was released and what was done to remediate the site after the release. Both dikes are free of fluids. |
1799272176 | 2019-04-29 | Salt Water Injection Well | Violations Noted | Our records indicate that the Division has not received the Salt Water Injection Well Annual Report (Form 204) that was due on April 15th for 2018, Please submit the Form 204 to the Division by 5/29/2019. |
1812297949 | 2003-05-20 | Salt Water Injection Well | No Violations | Follow-up on NOV, In-Compliance, met company at well site. |
1819623827 | 2019-6-18 0:00: | SW | No Violations | 3.00 |
1859388636 | 2005-10-14 | Salt Water Injection Well | No Violations | There were no violations at the time. |
1875603861 | 2007-06-04 | Salt Water Injection Well | No Violations | No violations were found. |
1936518435 | 2010-08-31 | Salt Water Injection Well | No Violations | 2 100 bbl steel tanks have been drained. New 30 mil liner has come in. Company is waiting on 2 new 100bbl steel tanks to arrive before starting the project. The second dike with 3-6000 gallon tanks has been pumped down 12, dike still has between 1 and 3 of water in low areas of dike. |
194209111 | 2008-6-10 0:00: | SW | No Violations | |
1942460667 | 2014-09-24 | Salt Water Injection Well | No Violations | Follow up to -1222998948. The fittings have been replaced. |
1963958168 | 2009-05-06 | Salt Water Injection Well | No Violations | No violations were found at the time. |
1995672921 | 2020-9-2 0:00:0 | SW | No Violations | 3.00 |
20041082 | 2007-7-17 0:00: | SW | No Violations | |
2010419901 | 2006-06-06 | Salt Water Injection Well | No Violations | There were no violations at the time of inspection. |
2010913366 | 2019-11-1 0:00: | SW | No Violations | 1.00 |
2035767506 | 2009-11-06 | Salt Water Injection Well | No Violations | Good identification. The injection operation was not in use at the time of inspection. |
2038694724 | 2010-06-24 | Administrative Inspection | No Violations | Talked to Tom Stone Re: leaking 100 bbl tank and replacing dike. Along with pumping out the fresh water in 3-6000 gal. tank dike. Tom said that they are going to replace both 100 bbl tanks and will look into replacing the dike liner at the same time. Tom told me that he has both 100 bbl tanks emptied. |
2039398735 | 2014-11-19 | Salt Water Injection Well | No Violations | No noted violations at facility. |
2078873787 | 2019-02-04 | Salt Water Injection Well | No Violations | Annulus mini test. Tested at 300 psi for 15 minutes with no loss in pressure. |
2082190644 | 2012-07-23 | Administrative Inspection | No Violations | Talked to John Kent and Tom Stone about the injection well status. They told me that they are planning an acid job soon. |
2093005892 | 2019-03-12 | Surface Facility Construction | No Violations | A tree fell on the electric service line and broke the electric pole. The transfer pump on the line between the two containment dikes has been removed for service. |
2097863273 | 2020-4-27 0:00: | SW | No Violations | 3.00 |
2119402806 | 2020-2-13 0:00: | SC | No Violations | 3.00 |
2128940937 | 2014-09-05 | Salt Water Injection Well | No Violations | Follow up to -1222998948. Still unable to test annulus. Called company and spoke to field supervisor and asked him to correct fittings. |
2134957181 | 2019-01-24 | Salt Water Injection Well | No Violations | Inspected the unloading pad, containment dikes, tanks, injection line, injection pressure and annulus pressure. Identification is posted. The injection tubing master valve is closed. The containment dikes have water and ice approximately 6 inches. Company was notified that a mini test needs to be done on the annulus. |
240283625 | 2017-7-31 0:00: | SW | No Violations | |
294491020 | 2017-2-23 0:00: | SW | No Violations | 1.00 |
399321842 | 2006-8-16 0:00: | SW | No Violations | |
427392225 | 2003-3-5 0:00:0 | SW | No Violations | |
506861824 | 2009-11-5 0:00: | SC | No Violations | |
514524137 | 2013-1-24 0:00: | SW | No Violations | 1.00 |
527703964 | 2015-4-28 0:00: | SW | No Violations | 0.50 |
635380578 | 2019-4-22 0:00: | SW | No Violations | 4.00 |
656929786 | 2009-6-9 0:00:0 | SW | No Violations | |
667869530 | 2011-8-24 0:00: | SW | No Violations | |
704144641 | 2009-11-6 0:00: | SC | No Violations | |
724406249 | 2005-5-10 0:00: | SW | No Violations | |
736867213 | 2016-1-6 0:00:0 | SW | No Violations | 0.70 |
737973241 | 2003-3-5 0:00:0 | SW | No Violations | |
739669403 | 2011-9-27 0:00: | SW | No Violations | |
742004490 | 2009-11-24 0:00 | SW | No Violations | |
746814585 | 2008-3-10 0:00: | SW | No Violations | |
753515775 | 2018-9-11 0:00: | SW | No Violations | 1.30 |
76793142 | 2011-12-15 0:00 | SW | No Violations | 1.00 |
778986041 | 2004-5-3 0:00:0 | SW | No Violations | |
783723975 | 2020-2-10 0:00: | SW | No Violations | 2.50 |
861642675 | 2013-10-30 0:00 | SW | No Violations | 0.60 |
PL11123 | PL | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0427392225 | US-OH-124557 | 2003-03-06 | Violation of injection tubing/fitting requirements | |
0427392225 | US-OH-124558 | 2003-03-06 | Failure to monitor pressures/volumes | |
0527703964 | US-OH-125764 | 2015-05-11 | Failure to monitor annulus pressure | |
0687807558 | US-OH-127790 | 2019-04-08 | Failure to report disposal fees | |
0737973241 | US-OH-128390 | 2003-03-06 | Violation of injection tubing/fitting requirements | |
0737973241 | US-OH-128391 | 2003-03-06 | Failure to monitor pressures/volumes | |
0782250667 | US-OH-128898 | 2018-08-03 | NONE | Failure to report disposal fees |
0996915144 | US-OH-131451 | 2012-03-07 | No SPCC dike/or failure to keep dike free of water or oil | |
1222998948 | US-OH-106004 | 2014-09-29 | Violation of injection tubing/fitting requirements | |
1252004373 | US-OH-106761 | 2009-09-03 | Pits not liquid tight/Improper construction or use | |
1271072997 | US-OH-107545 | 2010-04-12 | Failure to keep dike or pit free of brine or other wastes | |
1297660666 | US-OH-108370 | 2014-04-23 | Violation of injection tubing/fitting requirements | |
1350659426 | US-OH-110162 | 2012-10-19 | No SPCC dike/or failure to keep dike free of water or oil | |
1354126946 | US-OH-110247 | 2012-12-10 | Well operation causing pollution and contamination | |
1374084100 | US-OH-111077 | 2012-02-17 | No SPCC dike/or failure to keep dike free of water or oil | |
1534352012 | US-OH-114760 | 2018-08-16 | 9-3-04(A) | Pollution/Contamination |
1534352012 | US-OH-114761 | 2018-08-16 | 9-3-05(A)6 | Contamination at surface facility (permit after 6-1-82) |
1690649312 | US-OH-116756 | 2005-10-20 | Failure to monitor pressures/volumes | |
1700705447 | US-OH-116861 | 2010-06-29 | Pollution/Contamination | |
1700705447 | US-OH-116862 | 2010-06-29 | Pits not liquid tight/Improper construction or use | |
1700705447 | US-OH-116863 | 2010-06-29 | Tanks not liquid tight/Improper burial | |
1795553448 | US-OH-117919 | 2016-05-25 | Failure to file salt water injection annual report | |
1799272176 | US-OH-117959 | 2019-05-09 | Failure to file salt water injection annual report |
For data sources see[9]