34-167-25777

Well Details

Well ID: 34-167-25777
Loading map...
Country: United States
State: Ohio
County: Washington
Municipality: Adams Township
Operator Name: FREDERICK PETROLEUM LLC
Well Pad ID:
Farm/Lease Name: MN & S PRODUCTION INC
License Status: Producing
License Date: 1980-08-11
Spud Date: 1980-10-09
Spud Drilling Contractor:
Final Drill Date: 1980-10-16
Well Total Depth: 1895.00 ft
Configuration: Vertical
Latitude: 39.550000
Longitude: -81.500000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1980-08-11 1629 BETHEL OIL & GAS CO GeoDate 8/11/80
Original Spud 1980-10-09
Completed 1980-10-16
Reached Total Depth 1980-10-16
Change of Owner 1997-12-05 Operator changed from 1629, BETHEL OIL & GAS CO to 6009, MORRISON TOM
Record Last Modified 2014-02-12

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 1796 1806 6
1796 1806 6
1796 1806 6

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1000 Bbl 55000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1987 BUCKEYE CRUDE EXPL INC 0.00 0.00 17
1989 BETHEL OIL & GAS CO 0.00 0.00 206
2015 FREDERICK PETROLEUM LLC 0.00 0.00 365
2016 FREDERICK PETROLEUM LLC 0.00 0.00 0
2017 FREDERICK PETROLEUM LLC 0.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1987 BUCKEYE CRUDE EXPL INC Brine 0 17
1989 BETHEL OIL & GAS CO Brine 0 206
2015 FREDERICK PETROLEUM LLC Brine 0 365
2016 FREDERICK PETROLEUM LLC Brine 0 0
2017 FREDERICK PETROLEUM LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-116592768 2019-11-26 0:00 PW No Violations 0.50
-1737800081 2020-6-2 0:00:0 PW No Violations 0.40
-1794533343 2017-11-17 0:00 PW No Violations 1.00
-1819980462 2016-7-15 0:00: PW No Violations 2.00
-2058758367 2019-4-9 0:00:0 PW No Violations 1.00
-618977971 2017-6-29 0:00: PW No Violations 1.00
0088575771 2016-08-03 Production Wells No Violations My inspection today finds the identification has not been posted and the area affected by the brine has not been addressed. I stopped at the well owners home and called the telephone number, but was unable to reach him. I left a telephone message for him to call me back.
0477438526 2004-03-03 Production Wells No Violations Inspection this day found well not in production, capable and equipped with jack, owner says hole in the tubing and has order in for service rig, no IDs at well, tank on next road down below well. JOE - update lat/long, map wrong!
0618977971 2017-06-29 Production Wells No Violations The inspection this day revealed that this well is equipped with a pumping unit, a 4 1/2 inch diameter production casing, and 1 1/2 inch diameter production tubbing. The well was written up for contamination by Supervisor Eric Conrad. While I was on location I could see there was new soil where the contamination has been cleaned up. The power pole and tanks have been removed from location. All contamination has been removed from location. This well is now in compliance.
0969493251 2018-09-24 Production Wells Violations Noted On this day, I am conducting an inspection per request of Southwest Supervisor Eric Conrad. Frederick Petroleum (owner #6009), has failed to maintain liability insurance (Chiefs Order 2017-24). The well is equipped with 4.5 inch diameter casing, 2 inch diameter tubing, rods, and a pumping unit with an electric motor. The well appears capable of production. The casing valve is closed, and the tubing valve is open to a plastic flowline running into a polymer tank near the wellhead. There is (1) 1,000 gallon polymer tank and a welded steel cube storage tank that measures 6 x 6 x 6. There are no flowlines attached to the steel tank. Additionally, the drain valve to the polymer tank is open with stressed vegetation approximately 4 feet wide and 20 feet long, running downhill into a wooded valley. The area was tested with a Low Range Quantab with results of 300 parts per million. It will be noted that the fluid sample was tested during a rain event. Production records are current with 0s reported from 2015 - 2017. I spoke with Mr. Tom Morrison of Frederick Petroleum on 9/18/18, and he indicated that he currently owns the wells and is aware that his liability insurance has lapsed. Pictures were taken. The contaminated soil will need to be removed and disposed of properly, establish new vegetation, place identification at the wellhead, and adjust the tanks to meet the minimum required setback spacing of 50 feet from the wellhead.
1499083435 2017-06-30 Production Wells No Violations My inspection today corroborates the findings of Inspector Sefcik.
1502122469 2017-06-30 Production Wells No Violations My inspection corroborates the inspectors findings.
1544535911 2018-12-11 Production Wells No Violations On this day, I am conducting a compliance notice follow-up inspection. No identification has been posted and the tanks have not been adjusted to meet the minimum setback distance from the wellhead. There does not appear to be an attempt to address the residually contaminated soil at the base of the polymer tank. No new pollution and contamination appears to have been released. It will be noted that its 20 degrees Fahrenheit, and the ground is frozen around the tank. The well is equipped with 4.5 inch diameter casing with the valve closed, and 2 inch tubing with the valve is open. A flowline runs from the tubing to a 1,000 gallon polymer tank. There is a steel cube storage tank, approximately 35 barrels, but no lines run from the wellhead to the tank. A drain valve at the base of the storage tank is closed with a 2 inch plastic line attached, and placed on the downhill slope behind the tank. The well is setup to be produced by means of a pumping unit with rods and an electric motor. I spoke with Mr. Tom Morrison on 12/11/2018, and he stated that the well is not pumping, there has been no new release of fluid, and that he is in the process of selling the land and the well. He also indicated that there is oil inside the steel tank, and that he plans to remove both tanks from the property. Updated pictures were taken.
1581522838 2020-2-12 0:00: PW No Violations 0.30
1794533343 2017-11-17 Production Wells No Violations This well was not in production. I spoke with the well owner who confirmed his wells were shut in and not producing, because he couldnt afford the insurance.
1819980462 2016-07-15 Production Wells Violations Noted My inspection today finds the well is equipped with a pumping unit that is powered by an electric motor. An active electric service meter is located on a pole forty feet from the wellhead. A one inch pipeline is running from the casing head towards a dwelling with the valves open. A one inch plastic pipeline runs from the pumping tee to a water separator (knockout) on top of a fifty barrel steel tank. A small amount of oil was standing at the base of the fifty barrel tank. An area 10 by 4 of brine affected soil is located to the Northwest of the base of the tank. No identification could be found at the location. The landowner and well owner Tom Morrison arrived on location and informed me that the compliant was levied by a tenant that he recently evicted from the property. Mr. Morrison stated that the well is used for domestic gas. I informed Mr. Morrison of the violation for failure to legibly identify the well 1501:9-9-05(A)10 and gave him until 8/01/2016 to place identification at the well site and clean the area affected by the oil and brine.
2058758367 2019-04-09 Production Wells No Violations On this day, I am conducting a compliance notice follow-up and order-follow-up inspection. Frederick Petroleum (owner #6009), has failed to maintain liability insurance (Chiefs Order 2017-24). No progress has been made to gain compliance. The well is equipped with 4.5 inch diameter casing and 2 inch diameter tubing. There is a low pressure regulator present on the 4.5 inch casing with the valve closed, and a plastic flowline running into the polymer tank from the tubing with the valve open. It is setup to be produced by means of a pumping unit with rods and an electric motor. Vines are grown through the drive wheel on the unit. The polymer tank and steel cube tank still reside within close proximity to the well. A drain line running downslope from the base of the steel cube tank is present with the valve closed. No new pollution and contamination is witnessed. No identification is present at the tank or wellhead. Updated pictures were taken.
477438526 2004-3-3 0:00:0 PW No Violations
88575771 2016-8-3 0:00:0 PW No Violations 2.00
969493251 2018-9-24 0:00: PW No Violations 1.50

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0969493251 US-OH-131122 2018-10-15 9-1-07 Well operation causing pollution and contamination
0969493251 US-OH-131123 2018-10-15 9-9-05(A)10 Failure to legibly identify well
0969493251 US-OH-131124 2018-10-15 9-9-05(A)2 Violation of tank spacing requirements
1819980462 US-OH-118175 2018-02-28 9-1-07 Well operation causing pollution and contamination
1819980462 US-OH-118176 2018-02-28 9-9-05(A)10 Failure to legibly identify well

For data sources see[9]

References