X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-041-20160

Well Details

Well ID: 34-041-20160
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date:
Unconventional:
Horizontal:
Producing:
Violations:
Latitude:
Longitude:

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-1032556554 2013-12-18 Inspected the Alexander #1 (SWIW #6) as part of a standard injection well status check. Check well, pressures, storage and identification. No change in status from previous inspection..
-1074569511 2011-05-10 Check well and storage, Ok. Valves on the well head are closed at this time.
-1115493886 2003-01-30 Weather: snow covered 25F 9:30 a.m. Inspection w/ Jeff Fry. Integrity of well checked ok. ID was present. Fluid is taken on gravity.
-14245604 2004-02-12 Met Mrs. Harmon (Pat). Husband Clint, passed away in January.This is the first time she has been to the well since. Small drip leak on injection line at 1 1/2" elbow. Plastic bucket placed under it until repaired. Mrs. Harmon will call when repaired. Did 9-3-04(A)
-1450119292 2009-12-16 Check well and storage, Ok. Vaves on well head are closed.
-1578036407 2008-09-04 Chk well and storge, Ok.
-1656724318 2006-05-19 Chk well and storage, Valve on the annulus is leaking and I can not chk the pressure. It has possitive pressure but has not been tested for some time. A pressure tset should be scheduled soon. The tank at the well head is full of holes and should be emptied and removed.
-1915680927 2006-12-14 Inspected well with Jeff Fry. There was no ID posted at the tank battery or the wellhead. There was no quarter inch tap on the injection, however it was determined that there was 0 psi. It was determined that there was positive pressure on the annulus.
-1971798664 2008-12-12 Check well and storage, Ok.
-2043322253 2013-02-28 Standard injection well status check, well is currently not being used for injection. Site, storage, identification ok.
-2092321176 2006-06-22 On site for routine inspection. The annulus has not been pressure tested for some time the well head fittings( i.e.: valves) will not allow for monitoring of the pressure due to deteriorated conditions.

A pressure test w/an inspector on the site should be arranged.

-460153209 2008-01-18 Chk well and storage, Ok.
-53895292 2006-02-02 Chk well and storage, need to pressure test the annular space. Storage tank at the well head should not be used, it has holes in the side and is not liquid tight.
1053006842 2003-05-15 Well on gravity.
1057681019 2003-07-08 Injection done on gravity. ID, dikes ok.
1078763489 2004-03-08 Plumbing leak at well on elbow has been replaced and repaired.

Well is gravity pressure over 125 on annulus.

1099057347 2004-10-29 Chk well and storage, Ok.
1109706002 2005-03-01 Snow cover and snowing. Facility appears ok. Well takes fluid on gravity.
1187355800 2007-08-17 Chk well and stoage, Storage tank has been removed and the injection line has been unhooked from the well head. The well is incapable of being used for injection at this time. Approx 9:15 AM I talked to Mrs. Harmon and she told me the landowner has her in court over the well and that he is planing on having Jack Fishburne work the well over and set a new tank so that the well can be used.
1188225343 2007-08-27 On site for MIT. Pressured up to 300 psi, lost 5psi in 15 min, Past test. New tank of the same size has been installed. New well head fittings and injection line installed, quarter inch tap and a new gage on well head. Identification painted on the storage tank.
1192058254 2013-05-07 Inspect injection well, storage and identification. All valves shut, well shut-in. Currently testing feasibility of placing back online.
1194011892 2007-11-02 Chk well and storage,Ok.
1205246539 2008-03-11 Chk well and storage, on my last inspection of 01/18/08 I found that the storage tank needs a lid on the larger opening to prevent some one form falling into the tank. I phoned and told Mrs Harmon ot the problem and requested that a cover be put over the opening. As of this date the lid has not been installed as requested.
1205766719
1247147848 2009-07-09 Chk well and storage. Valves on well head closed. Vertical tank at storage site has the clean out hatch off of it.
1255456001 2009-10-13 Chk well and storage, Ok. Valves on tubing closed at the well head.
1268115589 2012-02-29 Inspect Well. Well shut in. Operator needs to service well and clean out.
1287i775 2002-06-04 need 1/4 inch valve on tubing .
1323268510 2011-12-07 An inspection revealed no violations. No injection at time of the inspection. A fitting has been installed on the injection side of well.
1345641434 2012-08-22 Inspected the Alexander #1 (SWIW #6) as part of a standard quarterly status check. Well is shut-in, back-side annulus pressure 120 psi. The well identification is clearly marked on the storage tank, the well is located inside the dike. Location entry is not marked well and is located at 1426 south galena road.
1351000233 2012-10-21 Inspected the Alaxander #1 (#160) (SWIW #6) as part of a standard injection well status check. Injection: shut-in, annulus: 125 pounds per square inch. Well identification and site OK.
1363783062 2013-03-20 Inspect injection well for dike and tank measurements. Dike 36'L x 25'W x 2'D. Tank 21' x 8' horizontal. (188 barrels at 100% capacity).
1364402602 2013-03-26 Received a forwarded email dated 3/26/2013 from Ms. Betsy Bender 1426 S. Galena Rd. regarding the flow line to the Alexander #1 (#160) (SWIW #6) which had parted. Contacted Ms. Bender 3/26/13 and discussed her concern that the line is broken and it may have caused a leak. Explained to her that the well is not in use and the line is shut-in on both sides (injection well and production well). Inspected the well on 3/26/13 and found the line had separated at a line slice (hose clamp came loose). No release occurred. Called Mr. Harry Kallipolitis of the Ohio EPA and informed him of the findings. Informed Inspector Tom Benko (UIC) of the findings and he met with the operator on location 3/27/13. Status: ok.
1364563310 2013-03-27 Inspect well, tanks and flow line with Bill Jackson, well tender. An Email message has been received identifying a broken flow line. During the inspection and site meeting it was reported the flow line previously broke due to a fallen tree with an oversized root ball. This break was repaired with a plumbers fitting and hose clamps. This splice was parted during the inspection. Inspection of the line revealed a total of three historic mechanical splices in the valley. No fluids were released from the flow line as the well has not been in production for an extended period of time. A previous repair the line is present near the production tanks, a new section of line was welded in place for this repair and is not of concern to this issue. The well and flow line have been shut in for several years and have not been utilized. During This inspection and previous inspections the operator reported that the well required servicing. The operator shall either repair the line, under the supervision of DNR inspectors, then pressure test the line, and put the well into production. Notification of the inspector is required prior to injecting fluids into the well. Or, remove the line and plug the injection well. The operator is being notified that a resolution is required within 60 days of this inspection report.
1385130763 2013-11-21 Inspected the Alexander #1 (SWIW #6) as part of a standard injection well status check. Check well, pressures, storage and identification. Status: well is not in operation.
1389993309 2014-01-17 Inspected the Alexander #1 (SWIW #6) as part of a standard injection well status check. Check well, pressures, storage and identification. No change in status from previous inspection.
1390920086 2014-01-28 Location Information. ENTRANCE: Lat. 40.23727 Long. -82.89856 / WELL HEAD: Lat. 40.23731 Long. -82 .90269 / CENTER-OF-STORAGE: Lat. 40.23729 Long. -82.90266. NOTE: the well head is located inside the storage dike.
1394803872 2014-03-14 Inspected the Alexander #1 (SWIW #6) as part of a standard injection well status check. Inspect well, pressures, storage and identification. Status: no change in status from previous inspection.
1407441478 2014-08-08 Inspect well for integrity and check pressures. Well is shut in. Storage tank is empty. Tank bottom is rusted near the inlet valve. The tank will need to be replaced or repaired prior to injection start up. The Flow line from the production well to the injection storage tank has not been replaced and is shut in.
147769300 2005-10-20 FAILURE TO SUBMIT ANNUAL SALTWATER INJECTION WELL REPORTS 9-3-07(E)
1523915151 2010-08-02 check well and storage, Ok.
1686462050 2011-06-06 Accompanied Brent Bear and Josh Garland on inspection.
1743075808 2013-08-21 Inspected the Alexander #1 (SWIW #6) as part of a standard injection well status check. Check well, storage and identification. The injection well remains out of service.
1795619021 2004-05-26 GPS updated. No activity at disposal site.
1831314502 2009-02-20 Chk well and storage, Ok.

Light snow cover.

1833493327 2012-05-21 Inspect Well. Shut in.
1843020609 2011-09-21 An inspection revealed no violations at this time. Unable to obtain injection pressure at this time, as there is no fitting available for gauge installation. Notified Mr. Bill Jackson, the representative for Patricia Harman to install 1/4" fitting on injection side. This location was tagged with ribbon for him to also reference. Note: Saltwater line from Permit 129 to this location had released brine and line has since been fused together and cleanup is ongoing. Please refer to Inspect Reports under Permit 129 for more details.
1979080600 2007-02-06 There was no ID posted at the tank battery or the wellhead. There was no quarter inch tap on the injection, however it was determined that there was 0 psi. It was determined that there was positive pressure on the annulus. I talked with the pumper Bob Bell. He indicated that the injection well is currently not in production and won't be until the spring when they plan to bring in a new tank.
2020863809 2011-06-06 An inspection revealed no violations at this time. No injection at time of inspection.
281644619 2007-08-22 Chk. Well and storage, new tank installed and all new fittings. New valves on well head, new injection line and filtration the well needs to have an MIT before starting to inject water. Valves on well and at the tank are closed at this time. Called Mrs Hrmond at approx. 1:50 PM talked about the pressure test and other miner leaks at the production site.
697622056 2009-03-19 Chk well and storage.
707073089 2006-12-01 Storage tank at the well head has been removed. Injection line unhooked, well not in use.
757029621 2010-03-30 Chk well and storage, ok.
783864130 2011-06-06 accompanied B.Bear on status check of SWIW well.