INSPECTION ID
|
DATE
|
DESCRIPTION
|
COMMENT
|
VIOLATION ID
|
VIOLATION CODE
|
VIOLATION_COMMENT
|
-1287900327
|
2005-11-23
|
|
Inspect Well. Pump jack; No motor. No ID. Moderate sour gas odor. Incapable of production. Plug permit has expired.
|
|
|
|
-1309839579
|
2012-04-27
|
|
Petroset pump cement through tubing to set bottom plug with 50/50 Poz.
|
|
|
|
-1832595104
|
2012-10-29
|
|
Inspect well location. Final restoration is complete and good. Land owner waver has been received to leave the plastic flow lines in the ground. Corn is standing. Measure with GPS the area impacted for crop damage; about 0.6 acres affected.
|
|
|
|
-1910109812
|
2012-05-07
|
|
Petro set was contacted to reset bottom plug with Class A Cement with loss circulation material including cotton seed hulls and cell flake and 3 % calcium chloride. Plug was bull headed into formation and pressured up to 1200 pounds of pressure.
|
|
|
|
-1925219945
|
2012-05-07
|
|
Approval was granted by Mike McCormac at 11:58 AM for plugging contractor to bull head well with Class A cement to kill well and set bottom plug second time due to thief of cement. No Hydrogen Sulfide Gas was observed during work.
|
|
|
|
-2140313118
|
2008-04-23
|
|
Inspect well. Pump jack, no motor. Heavily overgrown with vegetation. 1.5 inch tubing, 4 inch long string. STRONG ODOR FROM WELL.
|
|
|
|
-4024422
|
2003-04-04
|
|
Inspect Well. 8" slips to 4" pipe, Tee, and slips to 1.5" string. Polish rods. Pump jack. No motor. No Identification. Valves Rusted and closed. Well incapable of production. Moderate Odor of gas.
|
|
|
|
-805728942
|
2012-05-16
|
|
Top off well with 9 sac grout to surface. Moritz of Ashland delivered cement.
|
|
|
|
1305970835
|
2001-09-18
|
|
FOLLOW UP TO NOV # 84 Follow up on NOV # 23011. No change since last inspection by Insp. Mike Phelps. Well refered to orphan program.
|
|
NONE
|
|
1492553095
|
2001-09-17
|
|
FOLLOW UP TO NOV # 90 Follow up on NOV # 23011. No change since last inspection by Insp. Mike Phelps. Well refered to orphan program.
|
|
NONE
|
|
15832692
|
2011-05-09
|
|
Inspect well. Well with 4.5 inch casing, slips with 1.5 inch tubing, rods pump jack, rusted and leaking.
|
|
|
|
1885316095
|
2004-11-09
|
|
Crops in field. Direct inspection of well not possible. Inspection from road indicates pump jack is overgrown with vegetation. Id is not visible. Common tank with new id posted for permits 165, 171, and 172. Tank has been emptied.
|
|
|
|
2030207918
|
2012-05-04
|
|
Contacted by Plugging contractor to report that formation thieved the 50/50 Poz cement and the well blew out when setup to clean out for topping off well.
|
|
|
|
557483632
|
2004-12-08
|
|
Inspect Well. Plug application has expired. Pump jack on well, shut in. overgrown with vines. No ID posted at well head. New ID is posted at common tank with ID 165 and 171.
|
|
|
|
8473527
|
2001-09-18
|
|
Follow up on NOV # 23011. No change since last inspection by Insp. Mike Phelps
|
|
|
|
9073533
|
2001-09-17
|
|
Follow up on NOV # 23011. No change since last inspection by Insp. Mike Phelps.
|
|
|
|
941532434
|
2004-06-17
|
|
Inspect tanks, update tank location. 1 - 100 bbl common tank with permits 171.
|
|
|
|
CEN3228
|
1998-12-30
|
|
1509.12
|
|
12
|
|