X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-147-20412

Well Details

Well ID: 34-147-20412
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date:
Unconventional:
Horizontal:
Producing:
Violations:
Latitude:
Longitude:

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-1514498642 2012-02-16 At the time of my inspection the cable toool rig was moved off the well in preparation for service rig and power swivel to move on the well to drill into the Trenton. The 4" casing was reduced to 2" with a valve and shut in. No guage on well to detrmine pressure.
-1827278685 2012-03-01 At the time of my inspection, Universal Well Services was on site to do an acid treatment on the well. See Stimulation Report for details.
1237754775 2012-02-21 At the time of my inspection a Barry Well Service rig and power swivel was set up on the well to drill into the Trenton. Blow out preventor was fitted on 4" casing.
1322247307 2011-11-25 On site for cementing in of surface casing. Franklin Gas and Oil cable tool rig and PetroSet Cementing. Four separate fractures encountered during drilling (66'-68', 270'-272', 276'-280', and 290'-292'). 464' of 7" casing was set with baskets at 31' and 55'. Gas show at 387' and gas bubbling between surface casing and conductor casing. Circulation established before running cement and maintained during cement job (150 sacks Class A) but no cement returns to surface. Topped off with 40 sacks from surface that circulated cement around backside of conductor casing. Cement dropped back between 7" and conductor. Operator will tag cement and determine if further cement is needed.
1766817608 2012-09-20 At the time of my inspection all pits have been filled and the area around the well has been graded for farm use. The well has 460 psi of gas pressure and FRANKLIN GAS & OIL CO LLC is waiting for a sales line to be ran to the well. Preliminary Restoration Passed.