If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-117-22256 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.4021594823,"lon":-82.8684557665,"icon":""}]} |
County: | |
Municipality: | |
Operator Name: | |
Well Pad ID: | |
Farm/Lease Name: | |
First Permit Date: | |
Last Permit Date: | |
Spud Date: 1964-11-19 | |
Unconventional: | |
Horizontal: | |
Producing: No | |
Violations: 2 | |
Latitude: 40.4021594823 | |
Longitude: -82.8684557665 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|
PERIOD | TYPE | QUANTITY | UNITS | DISPOSAL METHOD | WASTE FACILITY PERMIT ID | WASTE FACILITY NAME | FACILITY CITY | FACILITY STATE |
---|
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION_COMMENT |
---|---|---|---|---|---|---|
-1866785177 | 2014-02-07 | Inspected the Williams #2 (#2256) as part of a standard production well status check. Inspect well, storage and identification. Status: ok. | ||||
1358259624 | 2013-01-15 | Inspected the Williams #2 (#2256) as part of a standard productive well status check. The well is pumping by a green and yellow painted Cabot electric powered pump jack. The storage consists of two 210 barrel tanks and a steel brine tank set in a gravel lined dike. The well identification and emergency contact information displayed at the storage is faded and needs replaced. "No Trespassing" signs are posted at the entrance. Gas is being pulled by vacuum pump from the well and is being vented to the atmosphere through a pvc pipe laying on the ground approximately 15 feet from the production equipment. Called Cortland Production Supervisor Gary VanDyke (1/18/13) and discussed the violations and he contacted Mr. Master's. They are planning to fix the violations on 1/19/13. Status: will continue to monitor. | 9-9-05(A)10 | |||
1358259624 | 2013-01-15 | Inspected the Williams #2 (#2256) as part of a standard productive well status check. The well is pumping by a green and yellow painted Cabot electric powered pump jack. The storage consists of two 210 barrel tanks and a steel brine tank set in a gravel lined dike. The well identification and emergency contact information displayed at the storage is faded and needs replaced. "No Trespassing" signs are posted at the entrance. Gas is being pulled by vacuum pump from the well and is being vented to the atmosphere through a pvc pipe laying on the ground approximately 15 feet from the production equipment. Called Cortland Production Supervisor Gary VanDyke (1/18/13) and discussed the violations and he contacted Mr. Master's. They are planning to fix the violations on 1/19/13. Status: will continue to monitor. | 9-9-05(B) | |||
1358871447 | 2013-01-22 | Inspected the Williams #2 (#2256) as a compliance agreement follow-up. Cortland Energy has extended the vent tubing to the required length and the well identification and emergency contact information has been posted. Status: Ok. | ||||
1395413705 | 2014-03-21 | Inspected the Williams #1 (#2256) as part of a standard production well status check. Inspect well, storage and identification. Status: Inspection revealed the pump jack unable to move in the up stroke and the motor running causing the belts to slip, squeal and smoke. Contacted operator who was out of town. Received permission to shut electric off at the power box to shut the well down. Also noted small pin hole leak on center tank #137651. Location was on the front, approximately 6 foot up from the bottom. The oil streak was active and making it to the gravel lined dike. Contacted operator. | ||||
1396357389 | 2014-04-01 | The operator has addressed the previously noted holes/leaks in center storage tank (#137651) by patching them with JB Weld (as per operator) and has freshly painted over the oil staining with silver paint. Separately, the belts on the pump jack motor have been replaced. Status: will continue to monitor. | ||||
1844343429 | 2004-10-21 | Chk well and storage, Ok. | ||||
576720318 | 2014-02-07 | Location Information. ENTRANCE: Lat. 40.40236 Long. -82.86837 / WELL HEAD: Lat. 40.40221 Long. -82.86854 / CENTER-OF-STORAGE: Lat. 40.40239 Long. -82.86846. | ||||
60861585 | 2007-10-03 | Chk well and storage,Ok. | ||||
619743837 | 2006-05-17 | Chk well and storage, Ok. |