{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.0220852893,"lon":-81.5528510305,"icon":""}]} |
County: | |
Municipality: | |
Operator Name: | |
Well Pad ID: | |
Farm/Lease Name: | |
First Permit Date: | |
Last Permit Date: | |
Spud Date: 1998-03-31 | |
Unconventional: | |
Horizontal: | |
Producing: No | |
Violations: 0 | |
Latitude: 41.0220852893 | |
Longitude: -81.5528510305 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|
PERIOD | TYPE | QUANTITY | UNITS | DISPOSAL METHOD | WASTE FACILITY PERMIT ID | WASTE FACILITY NAME | FACILITY CITY | FACILITY STATE |
---|
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION_COMMENT |
---|---|---|---|---|---|---|
-2057625660 | 2003-05-07 | Five Year MIT - Pressure test was conducted on the annular space between the nine inch and seven inch casings. The reference point was the pressure inside the 4-1/2 inch casing in the well.
Time Test Pressure Reference Pressure Difference 0855 672.177 245.510 426.667 0955 671.763 245.086 426.677 1055 670.993 244.346 426.647 1155 670.663 244.047 426.616 1255 670.056 243.422 426.634 1355 669.484 242.843 426.641 1455 668.904 242.274 426.630 1555 668.402 241.672 426.730 1655 668.328 241.651 426.677 The pressure loss averages 0.001 psi per hour. The MIT passes. |
||||
-2092954877 | 2004-10-26 | Status check inspection - no violations at this time. | ||||
112519988 | 2003-09-08 | Status check inspection - no violations at this time. | ||||
1279907322 | 2008-07-14 | Successfully completed the 5 year MIT for this well using Akron 67 tubing as the reference well. The pressure difference between the test well and the reference well over eight hours was 0.075 psi for an average of 0.0094 psi/hour.
Start Time End Time Start Diff End Diff Total Diff Avg/ hour 0805 1605 249.930 psi 249.855 psi 0.075 psi 0.0094 psi |
||||
1558140496 | 2013-06-24 | I witnessed a water-brine interface mechanical integrity test. The well passed.
My inspection was accompanied by Andrew Adgate. |
||||
1733007997 | 2009-06-18 | Columbus requested an annual inspection of the solution mining wells. This inspection found no violations at this time. | ||||
503718249 | 2010-08-03 | Annual inspection of this solution mining well found no violations at this time. Preliminary restoration also approved. |