34-121-24509

Well Details

Well ID: 34-121-24509
Loading map...
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 2014-07-11
Unconventional:
Horizontal:
Producing: No
Violations: 0
Latitude: 39.758108806
Longitude: -81.3919812643

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
1105085235 2014-08-08 I am onsite to witness the cementing operations of the surface casing string. Circulation could not be gained by the drilling rig. The decision was made to spot a 64 barrel balance plug at the base of the casing. 1.25" tubing was ran to a depth of 296' and 220 barrels of cement were circulated in place. The tubing was pulled and the fluid level was found at 160' from surface. I instructed the company to wait eight hours and the run the tubing back in and gain circulation before cementing to surface.
1378984440 2014-08-18 I am onsite to witness the casing integrity test. Several attempts were made before a problem with the pressure recording chart drive could be fixed. The casing lost less than ten percent of total pressure.