PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-1289758905 2006-02-15 No violations.
-1588274395 2011-11-15 No violations at this time.
-1972449963 2001-08-17 FOLLOW UP TO NOV # 5609i334 An inspection of the well revealed that there is No ID at the well and Restoration of well site has not been done drilling pits still open , mounts of dirt piled on site. Heater to close to well head , needs to be at least 50'ft from well. Brine line le NONEA
-1972449963 2001-08-17 FOLLOW UP TO NOV # 5609i334 An inspection of the well revealed that there is No ID at the well and Restoration of well site has not been done drilling pits still open , mounts of dirt piled on site. Heater to close to well head , needs to be at least 50'ft from well. Brine line le NONEC
-297600851 2007-02-07 No violations.
-713333891 2013-02-20 This well has a pumping unit on it with rods and 2" tubing. The identification is legible and meets 1501:9-9-05.
1049399659 2003-04-03 MIT / PDT , pressured-up 8 5/8" csg. , annulus to 410 lbs. For 1 hr. with no pressure drop / Test Passed.
1054056959 2003-05-27
1207931766 2008-04-08 AD test on well.
1365033287 2013-04-03 We did an integrity test on this well with nitrogen to make sure it holds pressure. The integrity test went good. Pressure tested at 420lbs for 1hr.
1432358178 2007-12-12 No violations.
1807785256 2011-07-20 No violations at this time.
34793425 2013-02-20 The well is capable of producing. The valves are open. It has a pumping unit on it with rods and 2" tubing. The identification is on the tank and the well. It is legible and meets 1509:9-9-05.
463159615 2012-02-13 Well capable of producing at this time.
5609i334 2001-08-17 An inspection of the well revealed that there is No ID at the well and Restoration of well site has not been done drilling pits still open , mounts of dirt piled on site. Heater to close to well head , needs to be at least 50'ft from well. Brine line leaking on well site , line needs repaired. NONEA
5609i334 2001-08-17 An inspection of the well revealed that there is No ID at the well and Restoration of well site has not been done drilling pits still open , mounts of dirt piled on site. Heater to close to well head , needs to be at least 50'ft from well. Brine line leaking on well site , line needs repaired. NONEC