X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-073-21949

Well Details

Well ID: 34-073-21949
Loading map...
County:
Municipality:
Operator Name:
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1982-10-18
Unconventional:
Horizontal:
Producing: No
Violations: 12
Latitude: 39.5016255884
Longitude: -82.3428111451

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS

Waste Data

PERIOD TYPE QUANTITY UNITS DISPOSAL METHOD WASTE FACILITY PERMIT ID WASTE FACILITY NAME FACILITY CITY FACILITY STATE

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION_COMMENT
-1168001730 2008-04-21 A follow-up inspection revealed that the company is working towards resolving FR.
-1257278333 2005-10-26 No violations, storage tanks have been removed, using production tanks on hill.
-126573055 2003-03-04 Follow-up on NOV, In-Compliance
-1504835184 2005-03-03 No violations.
-193956336 2005-06-09 FOLLOW UP TO NOV # 1246192697 An inspection of the well revealed oil and water in dike around storage tanks, it appears that a storage tank may be leaking. 9-9-05(A)8
-322820453 2005-04-06 No violations.
-386568954 2003-01-29 An inspection of the well revealed that the ID at the well and tanks is not legible, and water in dike around brine tank needs pumped out and need pressure on the annular side of well. REWRITE THE ID, PUMP OUT WATER, AND PRESSURE ANNULAR SIDE OF WELL 9-5-10(F)
-386568954 2003-01-29 An inspection of the well revealed that the ID at the well and tanks is not legible, and water in dike around brine tank needs pumped out and need pressure on the annular side of well. REWRITE THE ID, PUMP OUT WATER, AND PRESSURE ANNULAR SIDE OF WELL NONE(H)
-396207331 2004-02-26 No violations.
-781700336 2004-01-27 No violations.
-861585887 2006-10-06 Violations have not been resolved.
-974091041 2006-07-13 An inspection was conducted at the facility owned by Knox Energy Inc. on 7/13/2006. During the inspection, it was noted that there was no pressure at the injection or annulus sides of the well. A mini test will be required. On 7/19/2006, Mr. Dave Harris was informed of the deficiencies found during the inspection. 9-5-10(F)
1111207241 2004-08-19 An inspection of the well revealed for the past several months no pressure on injection or annulus side of well. Well has have a Mini test done. NEW LAT & LONG 9-5-09 C
1246192697 2005-06-09 An inspection of the well revealed oil and water in dike around storage tanks, it appears that a storage tank may be leaking. 9-9-05(A)8
1269i514 2001-11-13 An inspection of the well revealed that brine in the dike around the tanks, and was unable to check the pressures on the well. The 1/4" valve on the injection side needs replaced, and the 2" valve on the annulus side was closed unable to check pressure. 9-5-06
1269i514 2001-11-13 An inspection of the well revealed that brine in the dike around the tanks, and was unable to check the pressures on the well. The 1/4" valve on the injection side needs replaced, and the 2" valve on the annulus side was closed unable to check pressure. 9-5-09(A)(3)
1269i514 2001-11-13 An inspection of the well revealed that brine in the dike around the tanks, and was unable to check the pressures on the well. The 1/4" valve on the injection side needs replaced, and the 2" valve on the annulus side was closed unable to check pressure. 9-5-09(B)7
1269i699 2002-01-16 No violations.
1269i876 2002-03-19 No violations.
1269i952 2002-04-05 Follow-up on NOV, In-Compliance, done a MIT test on well and well passed test.
1273911706 2004-05-27 No violations.
1309772722 2007-11-19 An inspection revealed that the final restoration does not meet requirements. Steel pipe was observed alongside the lease road. NONEA
1907444339 2004-09-24 In-Compliance
1931152432 2003-10-27 No violations.
1956243145 2003-06-19 No violations.
2128308757 2007-03-20 On 3/20/2007, this well was plugged by Berry Well Service. The previously noted violation has been resolved.
227364717 2003-12-09 No violations.
311357203 2004-04-01 No violations.
315277806 2004-12-14 No violations.
34680978 2008-05-30 A follow-up inspection revealed that the final restoration meets requirements.
492694112 2006-11-20 A mini- test was performed on 11/20/2006. During the test, it was noted that the well was not holding pressure. Mr. Tom Tomastik was contacted and informed of the test results. A Chiefs Order will be issued requiring Knox Energy to suspend injection.
556078490 2003-05-06 No violations.
5609i212 2001-06-04 An inspection of the well revealed no pressure on the injection side or the annulus side, it appears it has been some time since the well has been mantained and tested. Request that the Company notify the Beverly Office and set up a date and time for testing packer(mini test). 9-5-10(E)
5609i212 2001-06-04 An inspection of the well revealed no pressure on the injection side or the annulus side, it appears it has been some time since the well has been mantained and tested. Request that the Company notify the Beverly Office and set up a date and time for testing packer(mini test). 9-5-10(G)
980662067 2003-07-24 No violations.
PL16358 Preliminary Restoration done information from Data Point
UIC462 1987-09-28 1501:9-3-06 (H)
UIC463 1987-09-28 1501:9-5-09 (B)(7)
UIC516 1988-04-05 1501:9-5-09 (A)(6)
UIC76 1986-12-29 1501:9-5-06
UIC77 1986-12-29 1501:9-5-09(A)(6)
UIC934 1990-06-18 1509.22 (A) (1)
UIC935 1990-06-18 1509: 9-5-06 PREVENT OF CONTAMIN
UIC936 1990-06-18 1501:9-5-09 (A) (6) CONSTRUCT & CONVERS.